3,001 research outputs found

    Adaptive dilation analysis for wavelet coding with EMDC

    Get PDF
    The Embedded Morphological Dilation Coding (EMDC) algorithm, recently proposed by the author of this work, implements a direct coding of the wavelet coefficients significance map that is based on the action of a new kind of multiresolution binary (bit-plane) morphological operator. EMDC actually includes the most part of existing morphological wavelet codecs, it produces a fully progressive bitstream with low complexity and has demonstrated competitive coding performances. A peculiar feature of EMDC is the adaptive and the extended connectivity nature of the morphological analysis of the subband coefficients. In this paper we give a detailed description of this feature and quantify the related performance improvements. We conclude that the considered pattern analysis and coding technique allow an increased reduction of the data redundancy and fills the gap between existing morphological dilation techniques and state-of-the-art wavelet coders

    High-Performance Embedded Morphological Wavelet Coding

    Get PDF
    Morphological analysis can be applied in wavelet domain to analyze and represent the position of significant coefficients. New operators have to be introduced which are able to exploit both the multiresolution and the filter bank peculiarities of the subband representation of visual information. In this paper an efficient morphological wavelet coder is proposed. The clustering trend of significant coefficients is captured by a new kind of multi resolution binary dilation operator. The layered and adaptive nature of this subband dilation makes it possible for the coding technique to produce an embedded bit-stream with a modest computational cost and state-of-the-art Rate-Distortion performance. Morphological wavelet coding appears promising because the localized analysis of wavelet coefficient clusters is adequate to capture intrinsic patterns of the source which can have substantial benefits for perceptual or even object-based reconstruction quality concerns. Here we test the performance of our algorithm and compare the effects of different wavelet filters. We obtain state of the art coding performance and good perceptual results both for 2D and 3D images, with a new technique that seems to be well suited for further developments

    Improving SPIHT-based Compression of Volumetric Medical Data

    Get PDF
    Volumetric medical data (CT,MR) are useful tools for diagnostic investigation however their usage may be made diffcult because of the amount of data to store or because of the duration of communication over a limited capacity channel. In order to code such information sources we present a progressive three dimensional image compression algorithm based on zerotree wavelet coder with arithmetic coding. We make use of a 3D separable biorthogonal wavelet transform and we extend the zerotree SPIHT algorithm to three dimensions. Moreover we propose some improvements to the SPIHT encoder in order to obtain a better rate distortion performance without increasing the computational complexity. Finally we propose an efficient context-based adaptive arithmetic coding which eliminates high order redundancy. The results obtained on progressive coding of a test CT volume are better than those presented in recent similar works both for the mean PSNR on the whole volume and for the PSNR homogeneity between various slices

    Radiation and magnetic field effects on new semiconductor power devices for HL-LHC experiments

    Full text link
    The radiation hardness of commercial Silicon Carbide and Gallium Nitride power MOSFETs is presented in this paper, for Total Ionizing Dose effects and Single Event Effects, under gamma, neutrons, protons and heavy ions. Similar tests are discussed for commercial DC-DC converters, also tested in operation under magnetic field

    High B test of a commercial step-down Point of Load for LHC experiments

    Get PDF
    The performance in magnetic field (B-field) of the commercial DC-DC converter LTM8033, from Linear Technology, has been evaluated. The tests have been carried out at the Laboratorio Acceleratori e Superconduttivit\ue0 Applicata (LASA), in Milan (Italy), on December 2013 and the experimental results are here presented and discussed. Their ability to operate in hostile environment is particularly interesting for physics experiments where the presence of radiation and strong B field make electronic devices challenged to function . In particular, in this article the operation in high B-field environment will be investigated and discussed

    On the effect of interactions beyond nearest neighbours on non-convex lattice systems

    Get PDF
    We analyse the rigidity of non-convex discrete energies where at least nearest and next-to-nearest neighbour interactions are taken into account. Our purpose is to show that interactions beyond nearest neighbours have the role of penalising changes of orientation and, to some extent, they may replace the positive-determinant constraint that is usually required when only nearest neighbours are accounted for. In a discrete to continuum setting, we prove a compactness result for a family of surface-scaled energies and we give bounds on its possible Gamma-limit in terms of interfacial energies that penalise changes of orientation

    Protocollo di valutazione infettivologica pre-trapianto

    Get PDF
    Lo screening pre-trapianto dei potenziali candidati a un trapianto d\u2019organo \ue8 parte essenziale del trapianto di organi solidi. Obiettivi dello screening pre-trapianto sono: 1. identificazione di condizioni che controindicano il trapianto; 2. identificazione e trattamento di infezioni attive pre-trapianto; 3. definizione del livello di rischio infettivo e impostazione di strategie preventive post-trapianto. Nonostante vi sia un generale accordo sulle indagini di screening da effettuare, vi sono alcune variazioni tra i diversi centri. Allo scopo di armonizzare lo screening infettivologico pre-trapianto, viene schematicamente riportato, alla luce dell\u2019esperienza personale e dei dati di letteratura, lo stato dell\u2019arte inerente lo screening infettivologico pre-trapianto

    The role of clinically significant antiphospholipid antibodies in systemic lupus erythematosus

    Get PDF
    The objective is to investigate the role of clinically significant antiphospholipid antibodies (aPL) in a cohort of systemic lupus erythematosus (SLE) patients. All SLE patients followed for at least 5 years and with available aPL profile at the beginning of the follow-up in our center were studied. Clinically significant aPL were defined as: positive lupus anticoagulant test, anti-cardiolipin and/or anti- β2Glycoprotein I IgG/IgM >99th percentile on two or more occasions at least 12 weeks apart. Patients with and without clinically significant aPL were compared by univariate (Chi square or Fisher's exact test for categorical variables and Student's t or Mann-Whitney test for continuous variables) and multivariate analysis (logistic regression analysis). P values <0.05 were considered significant. Among 317 SLE patients studied, 117 (37%) had a clinically significant aPL profile at baseline. Such patients showed at univariate analysis an increased prevalence of deep venous thrombosis, pulmonary embolism, cardiac valvular disease, cognitive dysfunction and antiphospholipid syndrome (APS), but a reduced prevalence of acute cutaneous lupus and anti-extractable nuclear antigens (ENA) when compared with patients without clinically significant aPL. Multivariate analysis confirmed the association between clinically significant aPL and reduced risk of acute cutaneous lupus [p=0.003, odds ratio (OR) 0.43] and ENA positivity (p<0.001, OR 0.37), with increased risk of cardiac valvular disease (p=0.024, OR 3.1) and APS (p<0.0001, OR 51.12). Triple positivity was the most frequent profile and was significantly associated to APS (p<0.0001, OR 28.43). Our study showed that one third of SLE patients had clinically significant aPL, and that this is associated with an increased risk, especially for triple positive, of APS, and to a different clinical and serological pattern of disease even in the absence of APS
    • …
    corecore