19 research outputs found

    Stress echo 2020 : the international stress echo study in ischemic and non-ischemic heart disease

    Get PDF
    Background: Stress echocardiography (SE) has an established role in evidence-based guidelines, but recently its breadth and variety of applications have extended well beyond coronary artery disease (CAD). We lack a prospective research study of SE applications, in and beyond CAD, also considering a variety of signs in addition to regional wall motion abnormalities. Methods: In a prospective, multicenter, international, observational study design, > 100 certified high-volume SE labs (initially from Italy, Brazil, Hungary, and Serbia) will be networked with an organized system of clinical, laboratory and imaging data collection at the time of physical or pharmacological SE, with structured follow-up information. The study is endorsed by the Italian Society of Cardiovascular Echography and organized in 10 subprojects focusing on: contractile reserve for prediction of cardiac resynchronization or medical therapy response; stress B-lines in heart failure; hypertrophic cardiomyopathy; heart failure with preserved ejection fraction; mitral regurgitation after either transcatheter or surgical aortic valve replacement; outdoor SE in extreme physiology; right ventricular contractile reserve in repaired Tetralogy of Fallot; suspected or initial pulmonary arterial hypertension; coronary flow velocity, left ventricular elastance reserve and B-lines in known or suspected CAD; identification of subclinical familial disease in genotype-positive, phenotype- negative healthy relatives of inherited disease (such as hypertrophic cardiomyopathy). Results: We expect to recruit about 10,000 patients over a 5-year period (2016-2020), with sample sizes ranging from 5,000 for coronary flow velocity/ left ventricular elastance/ B-lines in CAD to around 250 for hypertrophic cardiomyopathy or repaired Tetralogy of Fallot. This data-base will allow to investigate technical questions such as feasibility and reproducibility of various SE parameters and to assess their prognostic value in different clinical scenarios. Conclusions: The study will create the cultural, informatic and scientific infrastructure connecting high-volume, accredited SE labs, sharing common criteria of indication, execution, reporting and image storage of SE to obtain original safety, feasibility, and outcome data in evidence-poor diagnostic fields, also outside the established core application of SE in CAD based on regional wall motion abnormalities. The study will standardize procedures, validate emerging signs, and integrate the new information with established knowledge, helping to build a next-generation SE lab without inner walls

    Quality control of B-lines analysis in stress Echo 2020

    Get PDF
    Background The effectiveness trial “Stress echo (SE) 2020” evaluates novel applications of SE in and beyond coronary artery disease. The core protocol also includes 4-site simplified scan of B-lines by lung ultrasound, useful to assess pulmonary congestion. Purpose To provide web-based upstream quality control and harmonization of B-lines reading criteria. Methods 60 readers (all previously accredited for regional wall motion, 53 B-lines naive) from 52 centers of 16 countries of SE 2020 network read a set of 20 lung ultrasound video-clips selected by the Pisa lab serving as reference standard, after taking an obligatory web-based learning 2-h module ( http://se2020.altervista.org ). Each test clip was scored for B-lines from 0 (black lung, A-lines, no B-lines) to 10 (white lung, coalescing B-lines). The diagnostic gold standard was the concordant assessment of two experienced readers of the Pisa lab. The answer of the reader was considered correct if concordant with reference standard reading ±1 (for instance, reference standard reading of 5 B-lines; correct answer 4, 5, or 6). The a priori determined pass threshold was 18/20 (≥ 90%) with R value (intra-class correlation coefficient) between reference standard and recruiting center) > 0.90. Inter-observer agreement was assessed with intra-class correlation coefficient statistics. Results All 60 readers were successfully accredited: 26 (43%) on first, 24 (40%) on second, and 10 (17%) on third attempt. The average diagnostic accuracy of the 60 accredited readers was 95%, with R value of 0.95 compared to reference standard reading. The 53 B-lines naive scored similarly to the 7 B-lines expert on first attempt (90 versus 95%, p = NS). Compared to the step-1 of quality control for regional wall motion abnormalities, the mean reading time per attempt was shorter (17 ± 3 vs 29 ± 12 min, p < .01), the first attempt success rate was higher (43 vs 28%, p < 0.01), and the drop-out of readers smaller (0 vs 28%, p < .01). Conclusions Web-based learning is highly effective for teaching and harmonizing B-lines reading. Echocardiographers without previous experience with B-lines learn quickly.info:eu-repo/semantics/publishedVersio

    Chirurgia Odontostomatologica

    No full text
    Il testo rappresenta un’opera completa per l’apprendimento della chirurgia orale, da cui traspare la grande esperienza clinica degli AA. Le note di patologia, preliminari di ogni capitolo, rendono completa la trattazione, la vasta mole iconografica, la provata pluriennale esperienza didattica, nonché originali note di impostazioni terapeutiche, contribuiscono a rendere chiaro ed evidente lo sviluppo del piano terapeutico. Il testo si propone senza dubbio in primo piano sullo scenario di consultazione per studenti e professionisti

    Questioni di inizio vita

    No full text
    Il C.I.R.B. (Centro Interuniversitario di Ricerca Bioetica), cui aderiscono tutte le Università campane, è un organismo di ricerca nel quale - con metodo rigorosamente scientifico, grazie al concorso di qualificati cultori delle varie discipline interessate e in un clima di costante e costruttivo dialogo con i rappresentanti delle diverse posizioni culturali - è possibile delineare le trame di una serena e ponderata riflessione comune su tematiche che coinvolgono l’identità stessa della persona umana e il destino delle generazioni future

    Feasibility and value of two-dimensional volumetric stress echocardiography

    No full text
    Stroke volume response during stress is a major determinant of functional status in heart failure and can be measured by two-dimensional (2-D) volumetric stress echocardiography (SE). The present study hypothesis is that SE may identify mechanisms underlying the change in stroke volume by measuring preload reserve through end-diastolic volume (EDV) and left ventricular contractile reserve (LVCR) with systolic blood pressure and end-systolic volume (ESV)

    Stress Echo 2030 : the novel ABCDE-(FGLPR) protocol to define the future of imaging

    No full text

    Stress echo 2030: The novel ABCDE-(FGLPR) protocol to define the future of imaging

    Get PDF
    With stress echo (SE) 2020 study, a new standard of practice in stress imaging was developed and disseminated: The ABCDE protocol for functional testing within and beyond CAD. ABCDE protocol was the fruit of SE 2020, and is the seed of SE 2030, which is articulated in 12 projects: 1-SE in coronary artery disease (SECAD); 2-SE in diastolic heart failure (SEDIA); 3-SE in hypertrophic cardiomyopathy (SEHCA); 4-SE post-chest radiotherapy and chemotherapy (SERA); 5-Artificial intelligence SE evaluation (AI-SEE); 6-Environmental stress echocardiography and air pollution (ESTER); 7-SE in repaired Tetralogy of Fallot (SETOF); 8-SE in post-COVID-19 (SECOV); 9: Recovery by stress echo of conventionally unfit donor good hearts (RESURGE); 10-SE for mitral ischemic regurgitation (SEMIR); 11-SE in valvular heart disease (SEVA); 12-SE for coronary vasospasm (SESPASM). The study aims to recruit in the next 5 years (2021-2025)≥10,000 patients followed for≥5 years (up to 2030) from≥20 quality-controlled laboratories from≥10 countries. In this COVID-19 era of sustainable health care delivery, SE2030 will provide the evidence to finally recommend SE as the optimal and versatile imaging modality for functional testing anywhere, any time, and in any patient
    corecore