31 research outputs found

    Congenital complete atrioventricular block in the early pediatric population

    Get PDF
    Congenital complete atrioventricular block (CCAVB) is a rare potentially lethal disease with an estimated incidence of 1 every 15.000 to 20.000 live born infants

    Conflicting gender-related differences in the natural history of patients with Idiopathic Dilated Cardiomyopathy

    Get PDF
    Objective. To evaluated possible clinical and instrumental, natural history and prognostic divergences in women and men with idiopathic dilated cardiomyopathy (IDCM). Patients and Methods. From 1988 to 2012, we evaluated 803 consecutive patients with IDCM recorded in the Heart Muscle Disease Registry of Trieste (Italy). All patients had serial follow-up evaluations at 6, 12, and 24 months, and subsequently every two years, or more frequently if clinically indicated. Results. Two hundred and twenty-seven patients (28%) were female. At first evaluation women were significantly older (48 vs. 45 years old, p = 0.008); presented more frequently left bundle branch block at ECG (38% vs. 28%, p = 0.01), smaller left ventricular end-diastolic indexed volume at echocardiography (85 vs. 93 ml/m2, p <0.002) and more frequently moderate to severe mitral regurgitation at Doppler (43% vs. 33%, p = 0.015). No differences in NYHA class, medical treatment and device implantation rates were found. During a median of 108 months follow-up, women showed a significantly lower ten-year total mortality/heart transplantation (20% vs. 32% respectively, p = 0.001) and cardiovascular mortality rates (9% vs. 15%, p = 0.024) despite a less marked clinical and echocardiographic improvement. Conclusions. In our population of patients with IDCM, women showed a better long-term prognosis notwithstanding a presentation with a more advanced disease and a lower clinical-instrumental improvement on optimal medical therapy compared to men.&nbsp

    Initial experience with the subcutaneous implantable cardioverter-defibrillator with the real costs of hospitalization analysis in a single Polish center

    Get PDF
    Background: The recent introduction of an entirely subcutaneous implantable cardioverter-defibril­lator (S-ICD) represents an important progress in the defibrillation technology towards a less invasive approach. This is a single-center observational study of S-ICD implantations in Poland. Methods: The S-ICD was implanted in 11 patients with standard indications for an ICD. Patients in whom the device was implanted were evaluated for adverse events and device function at hospital discharge. All hospitalization costs were calculated and summed up for all patients. Costs were divided into following categories: medical materials, pharmaceuticals, operating theatre staff, cardiology depart­ment staff, laboratory tests, non-laboratory tests and additional non-medical costs. Results: The mean age of patients was 51.6 ± 16.4 years, 9 were men and 2 were women. Four pa­tients had atrial fibrillation as the basal rhythm, 1 patient had atrial flutter and 6 patients had sinus rhythm. All patients had at least one condition that precluded the use of a traditional ICD system or the S-ICD was preferred due to other conditions, i.e. a history complicated transvenous ICD therapy (18%), anticipated higher risk of infection (27%), lack or difficult vascular access (18%), young age and anticipated high cumulated risk of lifetime device therapy (36%). The mean duration of the im­plantation procedure was 2 h. One patient developed a postoperative pocket hematoma. Mean total time of hospitalization was 28 (6–92) days. Average cost of hospitalization per patient was 21,014.29 EUR (minimal = 19,332.71 EUR and maximal = 24,824.14 EUR). Conclusions: S-ICD implantation appears to provide a viable alternative to transvenous ICD, espe­cially for patients without pacing requirements

    Conflicting gender-related differences in the natural history of patients with idiopathic dilated cardiomyopathy

    Get PDF
    Objective: To evaluated possible clinical and instrumental, natural history and prognostic divergences in women and men with idiopathic dilated cardiomyopathy (IDCM). Patients and Methods: From 1988 to 2012, we evaluated 803 consecutive patients with IDCM recorded in the Heart Muscle Disease Registry of Trieste (Italy). All patients had serial follow-up evaluations at 6, 12, and 24 months, and subsequently every two years, or more frequently if clinically indicated. Results: Two hundred and twenty-seven patients (28%) were female. At first evaluation women were significantly older (48 vs. 45 years old, p = 0.008); presented more frequently left bundle branch block at ECG (38% vs. 28%, p = 0.01), smaller left ventricular end-diastolic indexed volume at echocardiography (85 vs. 93 ml/m2, p <0.002) and more frequently moderate to severe mitral regurgitation at Doppler (43% vs. 33%, p = 0.015). No differences in NYHA class, medical treatment and device implantation rates were found. During a median of 108 months follow-up, women showed a significantly lower ten-year total mortality/heart transplantation (20% vs. 32% respectively, p = 0.001) and cardiovascular mortality rates (9% vs. 15%, p = 0.024) despite a less marked clinical and echocardiographic improvement. Conclusion: In our population of patients with IDCM, women showed a better long-term prognosis notwithstanding a presentation with a more advanced disease and a lower clinical-instrumental improvement on optimal medical therapy compared to men

    Clinical efficacy of ivabradine in patients with inappropriate sinus tachycardia: a prospective, randomized, placebo-controlled, double-blind, crossover evaluation

    Get PDF
    Objectives The purpose of this study was to investigate the role of ivabradine in the treatment of symptomatic inappropriate sinus tachycardia using a double-blind, placebo-controlled, crossover design. Background Due to its If blocking properties, ivabradine can selectively attenuate the high discharge rate from sinus node cells, causing inappropriate sinus tachycardia. Methods Twenty-one patients were randomized to receive placebo (n = 10) or ivabradine 5 mg twice daily (n = 11) for 6 weeks. After a washout period, patients crossed over for an additional 6 weeks. Each patient underwent symptom evaluation and heart rate assessment at the start and finish of each phase. Results After taking ivabradine, patients reported elimination of >70% of symptoms (relative risk: 0.25; 95% CI: 0.18 to 0.34; p < 0.001), with 47% of them experiencing complete elimination. These effects were associated with a significant reduction of heart rate at rest (from 88 ± 11 beats/min to 76 ± 11 beats/min, p = 0.011), on standing (from 108 ± 12 beats/min to 92 ± 11 beats/min, p < 0.0001), during 24 h (from 88 ± 5 beats/min to 77 ± 9 beats/min, p = 0.001), and during effort (from 176 ± 17 beats/min to 158 ± 16 beats/min, p = 0.001). Ivabradine administration was also associated with a significant increase in exercise performance. No cardiovascular side effects were observed in any patients while taking ivabradine. Conclusions In this cohort, ivabradine significantly improved symptoms associated with inappropriate sinus tachycardia and completely eliminated them in approximately half of the patients. These findings suggest that ivabradine may be an important agent for improving symptoms in patients with inappropriate sinus tachycardia

    Perioperative Sensor and Algorithm Programming in Patients with Implanted ICDs and Pacemakers for Cardiac Resynchronization Therapy

    No full text
    Background: ICDs and pacemakers for cardiac resynchronization therapy (CRT) are complex devices with different sensors and automatic algorithms implanted in patients with advanced cardiac diseases. Data on the perioperative management and outcome of CRT carriers undergoing surgery unrelated to the device are scarce. Methods: Data from 198 CRT device carriers (100 with active rate responsive sensor) were evaluated regarding perioperative adverse (device-related) events (A(D)E) and lead parameter changes. Results: Thirty-nine adverse observations were documented in 180 patients during preoperative interrogation, which were most often related to the left-ventricular lead and requiring intervention/reprogramming in 22 cases (12%). Anesthesia-related events occurred in 69 patients. There was no ADE for non-cardiac surgery and in pacemaker-dependent patients not programmed to an asynchronous pacing mode. Post-operative device interrogation showed significant lead parameter changes in 64/179 patients (36%) requiring reprogramming in 29 cases (16%). Conclusion: The left-ventricular pacing lead represents the most vulnerable system component. Comprehensive pre and post-interventional device interrogation is mandatory to ensure proper system function. The type of ICD function suspension has no impact on each patient&rsquo;s outcome. Precautionary activity sensor deactivation is not required for non-cardiac interventions. Routine prophylactic device reprogramming to asynchronous pacing appears inessential. Most of the CRT pacemakers do not require surgery-related reprogramming
    corecore