41 research outputs found

    Surgical Treatment of Neer Group VI Proximal Humeral Fractures: Retrospective Comparison of PHILOS® and Hemiarthroplasty

    Get PDF
    Background: Neer Group VI proximal humeral fractures often are related to persistent disability despite surgical treatment. We retrospectively compared the outcome after open reduction and internal fixation with the PHILOS® plate or primary hemiarthroplasty in patients with Neer Group VI fractures focusing on complications, shoulder function, health-related quality of life (SF-36), and potential risk factors for complications. Questions/purposes: The aim of this study was to compare the PHILOS® plate with primary hemiarthroplasty for treatment of specific Neer Group VI fractures. We asked whether (1) both procedures have comparable clinical and radiologic complication rates; (2) one procedure is superior in terms of revision rate; (3) objective and subjective shoulder function (Constant-Murley score) and health-related quality of life (SF-36) were comparable in both groups at final followup; and (4) there are clinical or radiologic predictors for complications in any group? Methods: Between 2002 and 2007, 44 consecutive patients (mean, 75.2years) with a Neer Group VI proximal humeral fracture were included. Twenty-two patients treated with a PHILOS® plate were compared with 22 patients treated by primary hemiarthroplasty. Both groups were similar in all criteria. At minimum followup of 12months (mean, 30months; range, 12-83months), radiographic control, Constant-Murley score, and SF-36 were performed. Results : Fourteen patients with complications (63.6%) were counted in the PHILOS® plate group, of which 10 (45.4%) needed revision surgery, mostly as a result of avascular necrosis and screw cut-outs. In the primary hemiarthroplasty group, only one patient needed revision surgery (4.5%). Smoking and steroid therapy were substantially associated with complications in the PHILOS® plate group. There were no differences between the two groups regarding Constant-Murley or SF-36 scores. Conclusions : Angular stable open reduction and internal fixation was associated with high complication and revision rates, especially in patients who smoked and those receiving steroid therapy. Primary hemiarthroplasty provides limited function, which had little influence on the quality of life in this elderly collective. There are predictive factors for complications after the treatment of Neer Group VI proximal humeral fractures with the PHILOS® plate. Primary hemiarthroplasty remains a good option, especially when treating elderly patients. Level of Evidence: Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidenc

    Peri-operative Mortality and Morbidity of Complex Abdominal Aortic Aneurysms Repair in Switzerland: A Swissvasc Report.

    Get PDF
    OBJECTIVE Complex abdominal aortic aneurysms (cAAA) pose a clinical challenge. The aim of this study was to assess the 30 day mortality and morbidity for open aneurysm repair (OAR) and fenestrated/branched endovascular aortic repair (F/BEVAR), and the effect of hospital volume in patients with asymptomatic cAAA in Switzerland. METHODS Retrospective, cohort study using data from Switzerland's national registry for vascular surgery, Swissvasc, including patients treated from 1 January 2019 to 31 December 2022. All patients with asymptomatic, true, non-infected cAAA were identified. Primary outcome was 30 day mortality and morbidity reported using the Clavien-Dindo classification. Outcomes were compared between OAR and F/BEVAR after propensity score weighting. RESULTS Of the 461 patients identified, 333 underwent OAR and 128 underwent F/BEVAR for cAAA. At 30 days, overall mortality rate was 3.3% after OAR and 3.1% after F/BEVAR (p = .76). Propensity scores weighted analysis indicated similar morbidity rates for both approaches: F/BEVAR (OR 0.69, 95% CI 0.45 - 1.05, p = .055); intestinal ischaemia (1.8% after OAR, 3.1% after F/BEVAR, p = .47) and renal failure requiring dialysis (1.5% after OAR, 5.5% after F/BEVAR, p = .024) were associated with highest morbidity and mortality. Treatment specific complications with high morbidity were abdominal compartment syndrome and lower limb compartment syndrome following F/BEVAR. Overall treatment volume was low for most of the hospitals treating cAAA in Switzerland; outliers with increased mortality were identified among low volume hospitals. CONCLUSION Comparable 30 day mortality and morbidity rates were found between OAR and F/BEVAR for cAAA in Switzerland; lack of centralisation was also highlighted. Organ specific complications driving mortality were renal failure, intestinal ischaemia, and limb ischaemia, specifically after F/BEVAR. Treatment in specialised high volume centres, alongside efforts to reduce peri procedural kidney injury and mesenteric ischaemia, offers potential to lower morbidity and mortality in elective cAAA treatment

    Monopyrrolische VorHiufer fur die Synthese des Uroporp hyrinogen -octani trils

    Get PDF
    Syntheses of the pre-uroporphinoid monopyrrolic derivatives porphobilinogen dinitrile, deaminomethyl-porphobilinogen dinitrile and 5-deaminomethyl-2-hydroxymethyl-porphobilinogen dinitrile make multiple use of the crystalline Mannich salt dimethyl- -methylidene-iminiumjodide as areagent for the introduction of cyanomethyl and ,B-cyanoethylside chains at the ,B-positionof the pyrrol nucleus. The paper is the first in a series of reports on the chemistry of uroporphyrinogen octanitrile

    Editor's Choice - Sex Related Differences in Indication and Procedural Outcomes of Carotid interventions in VASCUNET

    Get PDF
    Objective: It has been suggested that peri-operative complications after carotid surgery may be higher in women than in men. This assumption may affect the treatment patterns, and it is thus possible that carotid endarterectomy (CEA) is provided to women less often. The aim of the current VASCUNET study was to determine sex related differences in operative risk in routine clinical practice among non-selected patients undergoing carotid revascularisation. Methods: Data on CEA and carotid artery stenting (CAS) from 14 vascular registries were collected and amalgamated. Comprehensive data were available for 223 626 carotid artery procedures; these were analysed overall and by country. The primary outcome was any stroke and or death within 30 days of carotid revascularisation. Secondary outcomes were stroke, death, or any major cardiac event or haemorrhage leading to re-operation. Results: Of the procedures, 34.8% were done in women. The proportion of CEA for asymptomatic stenosis compared with symptomatic stenosis was significantly higher among women than men (38.4% vs. 36.9%, p < .001). The proportion of octogenarians was higher among women than men who underwent CEA in both asymptomatic (21.2% vs. 19.9%) and symptomatic patients (24.3% vs. 21.4%). In the unadjusted analysis of symptomatic and asymptomatic patients, there were no significant differences between men and women in the rate of post-operative combined stroke and or death, any major cardiac event, or combined death, stroke, and any major cardiac event after CEA. Also, after stenting for asymptomatic or symptomatic carotid stenosis, there were no significant differences between men and women in the rate of post-operative complications. In adjusted analyses, sex was not significantly associated with any of the end points. Higher age and CAS vs. CEA were independently associated with all four end points. Conclusion: This study confirmed that, in a large registry among non-selected patients, no significant sex related differences were found in peri-operative complication rates after interventions for carotid stenosis

    Chipimplementation einer zweidimensionalen Fouriertransformation für dieAuswertung eines Sensor-Arrays

    No full text
    In der Bachelorarbeit wird eine 8x8 zweidimensionale Fourier Transformation in VHDL für den Einsatz als Teilmodul auf einem ASIC entwickelt. Dabei wird das Chipdesign-Tool Cadence verwendet. Die Transformation wird durch eine Matrixmultiplikation realisiert und hinsichtlich Taktzyklen und Flächenbedarf optimiert, sodass ein minimaler Aufwand erforderlich ist. Ferner werden Tests zur Funktionalität durchgeführt und der Floorplan erstellt.In this bachelor thesis a 8x8 twodimensional Fourier transform is developed in VHDL as a partial modul for the usage on an ASIC. For the implementation the chipdesign tool Cadence is used. The transform is realized as a matrix multiplication and optimized in terms of clock cycles and required area. Functionality test are executed and the floorplan is created

    Surgical Treatment of Neer Group VI Proximal Humeral Fractures: Retrospective Comparison of PHILOS® and Hemiarthroplasty

    No full text
    BACKGROUND: Neer Group VI proximal humeral fractures often are related to persistent disability despite surgical treatment. We retrospectively compared the outcome after open reduction and internal fixation with the PHILOS(®) plate or primary hemiarthroplasty in patients with Neer Group VI fractures focusing on complications, shoulder function, health-related quality of life (SF-36), and potential risk factors for complications. QUESTIONS/PURPOSES: The aim of this study was to compare the PHILOS(®) plate with primary hemiarthroplasty for treatment of specific Neer Group VI fractures. We asked whether (1) both procedures have comparable clinical and radiologic complication rates; (2) one procedure is superior in terms of revision rate; (3) objective and subjective shoulder function (Constant-Murley score) and health-related quality of life (SF-36) were comparable in both groups at final followup; and (4) there are clinical or radiologic predictors for complications in any group? METHODS: Between 2002 and 2007, 44 consecutive patients (mean, 75.2 years) with a Neer Group VI proximal humeral fracture were included. Twenty-two patients treated with a PHILOS(®) plate were compared with 22 patients treated by primary hemiarthroplasty. Both groups were similar in all criteria. At minimum followup of 12 months (mean, 30 months; range, 12-83 months), radiographic control, Constant-Murley score, and SF-36 were performed. RESULTS: Fourteen patients with complications (63.6%) were counted in the PHILOS(®) plate group, of which 10 (45.4%) needed revision surgery, mostly as a result of avascular necrosis and screw cut-outs. In the primary hemiarthroplasty group, only one patient needed revision surgery (4.5%). Smoking and steroid therapy were substantially associated with complications in the PHILOS(®) plate group. There were no differences between the two groups regarding Constant-Murley or SF-36 scores. CONCLUSIONS: Angular stable open reduction and internal fixation was associated with high complication and revision rates, especially in patients who smoked and those receiving steroid therapy. Primary hemiarthroplasty provides limited function, which had little influence on the quality of life in this elderly collective. There are predictive factors for complications after the treatment of Neer Group VI proximal humeral fractures with the PHILOS(®) plate. Primary hemiarthroplasty remains a good option, especially when treating elderly patients

    Surgical treatment of Neer Group VI proximal humeral fractures: retrospective comparison of PHILOS® and hemiarthroplasty

    Full text link
    BACKGROUND: Neer Group VI proximal humeral fractures often are related to persistent disability despite surgical treatment. We retrospectively compared the outcome after open reduction and internal fixation with the PHILOS(®) plate or primary hemiarthroplasty in patients with Neer Group VI fractures focusing on complications, shoulder function, health-related quality of life (SF-36), and potential risk factors for complications. QUESTIONS/PURPOSES: The aim of this study was to compare the PHILOS(®) plate with primary hemiarthroplasty for treatment of specific Neer Group VI fractures. We asked whether (1) both procedures have comparable clinical and radiologic complication rates; (2) one procedure is superior in terms of revision rate; (3) objective and subjective shoulder function (Constant-Murley score) and health-related quality of life (SF-36) were comparable in both groups at final followup; and (4) there are clinical or radiologic predictors for complications in any group? METHODS: Between 2002 and 2007, 44 consecutive patients (mean, 75.2 years) with a Neer Group VI proximal humeral fracture were included. Twenty-two patients treated with a PHILOS(®) plate were compared with 22 patients treated by primary hemiarthroplasty. Both groups were similar in all criteria. At minimum followup of 12 months (mean, 30 months; range, 12-83 months), radiographic control, Constant-Murley score, and SF-36 were performed. RESULTS: Fourteen patients with complications (63.6%) were counted in the PHILOS(®) plate group, of which 10 (45.4%) needed revision surgery, mostly as a result of avascular necrosis and screw cut-outs. In the primary hemiarthroplasty group, only one patient needed revision surgery (4.5%). Smoking and steroid therapy were substantially associated with complications in the PHILOS(®) plate group. There were no differences between the two groups regarding Constant-Murley or SF-36 scores. CONCLUSIONS: Angular stable open reduction and internal fixation was associated with high complication and revision rates, especially in patients who smoked and those receiving steroid therapy. Primary hemiarthroplasty provides limited function, which had little influence on the quality of life in this elderly collective. There are predictive factors for complications after the treatment of Neer Group VI proximal humeral fractures with the PHILOS(®) plate. Primary hemiarthroplasty remains a good option, especially when treating elderly patients

    The PHILOS plate for proximal humeral fractures--risk factors for complications at one year

    Full text link
    BACKGROUND: Since 2003, we have used the Proximal Humerus Interlocking System plate for treatment of proximal humeral fractures. Although many patients have good and excellent results, the reported rate of complications varies. We have focused on the complication rate and risk factors for complications 1 year after surgery. METHODS: From 2003 until 2008, a total of 294 (223 women; 71 men; median age, 72.9) patients were included. General data were collected at the time of injury (Charlson Index, smoking, and steroid therapy). Fractures were classified (AO/OTA) retrospectively. The follow-up of 1 year included radiographs and Constant-Murley score for functionality. Complications and revision surgeries were analyzed specifically. RESULTS: We found 83 (28.2%) patients with a total of 105 complications, requiring a total of 72 (24.5%) revision surgeries. The most frequent complication was screw cutout (33 of 294, 11.2%), because of secondary fracture displacement or avascular necrosis (AVN). AVN (20 of 294, 6.8%) was the main reason for secondary arthroplasty. Smoking more than 20 pack years had a significant impact on the complication rate. Fractures classified 11-A3 showed more implant failures. Fracture dislocations predisposed to secondary screw cutout and AVN. Patients without complications (211, 71.8%) achieved a median Constant-Murley score of 89 (40-100) points. CONCLUSION: This study points out several predisposing factors for negative outcome after open reduction and internal fixation with the Proximal Humerus Interlocking System plate (fracture type: 11-A3, fracture dislocations, and smoking). Accounting for these, patient's risk for complications can be evaluated more individually and taken into consideration for the concept of treatment. Altering the surgical technique was associated with a significant reduction in the incidence of secondary screw cutout
    corecore