87 research outputs found

    Optical and chemical control of the wettability of nanoporous photoswitchable films

    Get PDF
    Wettability is a central surface property of functional thin films. Here, we present a nanoporous film made of an azobenzene-containing metal-organic framework material where the wettability is controlled by photoswitching of the fluorinated azobenzene moieties and by reversible incorporation of guest molecules with different polarities in the pores. Using both, the optical and the chemical stimuli, the water contact angle was modified over a wide range, from 23° to 97°

    Spinal alignment shift between supine and prone CT imaging occurs frequently and regardless of the anatomic region, risk factors, or pathology

    Get PDF
    Computer-assisted spine surgery based on preoperative CT imaging may be hampered by sagittal alignment shifts due to an intraoperative switch from supine to prone. In the present study, we systematically analyzed the occurrence and pattern of sagittal spinal alignment shift between corresponding preoperative (supine) and intraoperative (prone) CT imaging in patients that underwent navigated posterior instrumentation between 2014 and 2017. Sagittal alignment across the levels of instrumentation was determined according to the C2 fracture gap (C2-F) and C2 translation (C2-T) in odontoid type 2 fractures, next to the modified Cobb angle (CA), plumbline (PL), and translation (T) in subaxial pathologies. One-hundred and twenty-one patients (C1/C2: n = 17; C3-S1: n = 104) with degenerative (39/121; 32%), oncologic (35/121; 29%), traumatic (34/121; 28%), or infectious (13/121; 11%) pathologies were identified. In the subaxial spine, significant shift occurred in 104/104 (100%) cases (CA: *p = .044; T: *p = .021) compared to only 10/17 (59%) cases that exhibited shift at the C1/C2 level (C2-F: **p = .002; C2-T: *p 5 segments (" increment PL > 5 segments": 4.5 +/- 1.8 mm; " increment PL <= 5 segments": 2 +/- 0.6 mm; *p = .013) or in revision surgery with pre-existing instrumentation (" increment PL presence": 5 +/- 2.6 mm; " increment PL absence": 2.4 +/- 0.7 mm; **p = .007). Interestingly, typical morphological instability risk factors did not influence the degree of shift. In conclusion, intraoperative spinal alignment shift due to a change in patient position should be considered as a cause for inaccuracy during computer-assisted spine surgery and when correcting spinal alignment according to parameters that were planned in other patient positions

    Scope and limitations of ad hoc neural network reconstructions of solar wind parameters

    Full text link
    Solar wind properties are determined by the conditions of their solar source region and transport history. Solar wind parameters, such as proton speed, proton density, proton temperature, magnetic field strength, and the charge state composition of oxygen, are used as proxies to investigate the solar source region of the solar wind. The transport and conditions in the solar source region affect several solar wind parameters simultaneously. The observed redundancy could be caused by a set of hidden variables. We test this assumption by determining how well a function of four of the selected solar wind parameters can model the fifth solar wind parameter. If such a function provided a perfect model, then this solar wind parameter would be uniquely determined from hidden variables of the other four parameters. We used a neural network as a function approximator to model unknown relations between the considered solar wind parameters. This approach is applied to solar wind data from the Advanced Composition Explorer (ACE). The neural network reconstructions are evaluated in comparison to observations. Within the limits defined by the measurement uncertainties, the proton density and proton temperature can be reconstructed well. We also found that the reconstruction is most difficult for solar wind streams preceding and following stream interfaces. For all considered solar wind parameters, but in particular the proton density, temperature, and the oxygen charge-state ratio, parameter reconstruction is hindered by measurement uncertainties. The reconstruction accuracy of sector reversal plasma is noticeably lower than that of streamer belt or coronal hole plasma. The fact that the oxygen charge-state ratio, a non-transport-affected property, is difficult to reconstruct may imply that recovering source-specific information from the transport-affected proton plasma properties is challenging

    Seasonal variability of the warm Atlantic Water layer in the vicinity of the Greenland shelf break

    Get PDF
    The warmest water reaching the east and west coast of Greenland is found between 200?m and 600?m. Whilst important for melting Greenland's outlet glaciers, limited winter observations of this layer prohibit determination of its seasonality. To address this, temperature data from Argo profiling floats, a range of sources within the World Ocean Database and unprecedented coverage from marine-mammal borne sensors have been analysed for the period 2002-2011. A significant seasonal range in temperature (~1-2?°C) is found in the warm layer, in contrast to most of the surrounding ocean. The phase of the seasonal cycle exhibits considerable spatial variability, with the warmest water found near the eastern and southwestern shelf-break towards the end of the calendar year. High-resolution ocean model trajectory analysis suggest the timing of the arrival of the year's warmest water is a function of advection time from the subduction site in the Irminger Basin

    Spiral Microchannels with Trapezoidal Cross Section Fabricated by Femtosecond Laser Ablation in Glass for the Inertial Separation of Microparticles

    Get PDF
    The fabrication and testing of spiral microchannels with a trapezoidal cross section for the passive separation of microparticles is reported in this article. In contrast to previously reported fabrication methods, the fabrication of trapezoidal spiral channels in glass substrates using a femtosecond laser is reported for the first time in this paper. Femtosecond laser ablation has been proposed as an accurate and fast prototyping method with the ability to create 3D features such as slanted-base channels. Moreover, the fabrication in borosilicate glass substrates can provide high optical transparency, thermal resistance, dimensional stability, and chemical inertness. Post-processing steps of the laser engraved glass substrate are also detailed in this paper including hydrogen fluoride (HF) dipping, chemical cleaning, surface activation, and thermal bonding. Optical 3D images of the fabricated chips confirmed a good fabrication accuracy and acceptable surface roughness. To evaluate the particle separation function of the microfluidic chip, 5 ÎŒm, 10 ÎŒm, and 15 ÎŒm particles were focused and recovered from the two outlets of the spiral channel. In conclusion, the new chemically inert separation chip can be utilized in biological or chemical processes where different sizes of cells or particles must be separated, i.e., red blood cells, circulating tumor cells, and technical particle suspensions

    Three-Dimensional Iron Oxide Nanoparticle-Based Contrast-Enhanced Magnetic Resonance Imaging for Characterization of Cerebral Arteriogenesis in the Mouse Neocortex

    Get PDF
    Purpose: Subsurface blood vessels in the cerebral cortex have been identified as a bottleneck in cerebral perfusion with the potential for collateral remodeling. However, valid techniques for non-invasive, longitudinal characterization of neocortical microvessels are still lacking. In this study, we validated contrast-enhanced magnetic resonance imaging (CE-MRI) for in vivo characterization of vascular changes in a model of spontaneous collateral outgrowth following chronic cerebral hypoperfusion. Methods: C57BL/6J mice were randomly assigned to unilateral internal carotid artery occlusion or sham surgery and after 21 days, CE-MRI based on T2*-weighted imaging was performed using ultra-small superparamagnetic iron oxide nanoparticles to obtain subtraction angiographies and steady-state cerebral blood volume (ss-CBV) maps. First pass dynamic susceptibility contrast MRI (DSC-MRI) was performed for internal validation of ss-CBV. Further validation at the histological level was provided by ex vivo serial two-photon tomography (STP). Results: Qualitatively, an increase in vessel density was observed on CE-MRI subtraction angiographies following occlusion; however, a quantitative vessel tracing analysis was prone to errors in our model. Measurements of ss-CBV reliably identified an increase in cortical vasculature, validated by DSC-MRI and STP. Conclusion: Iron oxide nanoparticle-based ss-CBV serves as a robust, non-invasive imaging surrogate marker for neocortical vessels, with the potential to reduce and refine preclinical models targeting the development and outgrowth of cerebral collateralization
    • 

    corecore