19 research outputs found

    Hypothesis: hair cover can protect against invasive melanoma on the head and neck (Australia)

    Get PDF
    The anatomic distribution of cutaneous melanoma reflects people’s levels and patterns of sun exposure. While examining trends of incident invasive melanomas by site in recent decades in Australia we noted significant increases in incidence on the ears but not the face or any other site in women younger than 40 years, by 6% (95% confidence interval [CI] 2–10%) per year, and 40–59 years by 7% (95% CI 4–10%) per year. Men of the same age showed no corresponding changes in ear melanoma. However incidence rates of ear melanoma in general were fourfold higher in males than females in Australia. Further, using data from the National Cancer Institute’s Surveillance, Epidemiology and End Results (SEER) Program, rates of invasive melanoma on the ear were found to be sevenfold higher in males than females in the US population in the same period. Higher rates of scalp and neck melanomas were also seen in men and women in both populations. We therefore speculated that the isolated rises of ear melanoma in younger women in Australia, and the higher overall rates of ear, scalp and neck melanoma in men compared with women, reflect differences in hair coverage. We tested the specific hypothesis that hair cover reduces sun exposure of the ears using experimental manikins and found that hair cover of the ear reduced solar ultraviolet-B exposure by 81% [SE ±8] compared with uncovered ears. We conclude that hair cover can protect against invasive melanoma on the ear and may similarly protect on the scalp and neck. When discretionary, hair may be an important additional factor to be considered for melanoma prevention

    Protection against ultraviolet radiation by commercial summer clothing: need for standardised testing and labelling

    Get PDF
    BACKGROUND: The use of clothing as a means of sun protection has been recommended in recent education campaigns. Contrary to popular opinion, however, some fabrics provide insufficient ultraviolet (UV) protection. MATERIAL AND METHODS: We investigated 236 apparel textiles of the spring/summer collections 2000 and 2001. In accordance with the forthcoming European standard the UV protection factor (UPF) of the fabrics was determined spectrophotometrically. RESULTS: Seventy-eight (33%) fabrics had UPF < 15, 45 (19%) had UPF = or > 15 and < 30, and 113 (48%) had UPF = or > 30 (30+). More than 70% of the wool, polyester, and fabric blends, and only less than 30% of the cotton, linen, and viscose fabrics had UPF values of 30+. Fabrics with black, navy-blue, white, green, or beige colours provided most frequently UPF values of 30+. CONCLUSIONS: It is difficult for the sun-aware consumer to choose the 'right' garment, with a third of summer clothing providing insufficient UV protection and only half of the fabrics having UPF 30+, the UPF recommended by the European standard. Therefore, apparel summer fabrics should be measured and labelled in accordance with a standard document

    Low-Dose Imaging in a New Preclinical Total-Body PET/CT Scanner.

    Get PDF
    Ionizing radiation constitutes a health risk to imaging scientists and study animals. Both PET and CT produce ionizing radiation. CT doses in pre-clinical in vivo imaging typically range from 50 to 1,000 mGy and biological effects in mice at this dose range have been previously described. [ &lt;sup&gt;18&lt;/sup&gt; F]FDG body doses in mice have been estimated to be in the range of 100 mGy for [ &lt;sup&gt;18&lt;/sup&gt; F]FDG. Yearly, the average whole body doses due to handling of activity by PET technologists are reported to be 3-8 mSv. A preclinical PET/CT system is presented with design features which make it suitable for small animal low-dose imaging. The CT subsystem uses a X-source power that is optimized for small animal imaging. The system design incorporates a spatial beam shaper coupled with a highly sensitive flat-panel detector and very fast acquisition (&lt;10 s) which allows for whole body scans with doses as low as 3 mGy. The mouse total-body PET subsystem uses a detector architecture based on continuous crystals, coupled to SiPM arrays and a readout based in rows and columns. The PET field of view is 150 mm axial and 80 mm transaxial. The high solid-angle coverage of the sample and the use of continuous crystals achieve a sensitivity of 9% (NEMA) that can be leveraged for use of low tracer doses and/or performing rapid scans. The low-dose imaging capabilities of the total-body PET subsystem were tested with NEMA phantoms, in tumor models, a mouse bone metabolism scan and a rat heart dynamic scan. The CT imaging capabilities were tested in mice and in a low contrast phantom. The PET low-dose phantom and animal experiments provide evidence that image quality suitable for preclinical PET studies is achieved. Furthermore, CT image contrast using low dose scan settings was suitable as a reference for PET scans. Total-body mouse PET/CT studies could be completed with total doses of &lt;10 mGy

    Effect of repeated in vivo microCT imaging on the properties of the mouse tibia

    Get PDF
    In longitudinal studies, in vivo micro-Computed Tomography (microCT) imaging is used to investigate bone changes over time due to interventions in mice. However, ionising radiation can provoke significant variations in bone morphometric parameters. In a previous study, we evaluated the effect of reducing the integration time on the properties of the mouse tibia measured from microCT images. A scanning procedure (100 ms integration time, 256 mGy nominal radiation dose) was selected as the best compromise between image quality and radiation dose induced on the animal. In this work, the effect of repeated in vivo scans has been evaluated using the selected procedure. The right tibia of twelve female C57BL/6 (six wild type, WT, six ovariectomised, OVX) and twelve BALB/c (six WT, six OVX) mice was scanned every two weeks, starting at week 14 of age. At week 24, mice were sacrificed and both tibiae were scanned. Standard trabecular and cortical morphometric parameters were calculated. The spatial distribution of densitometric parameters (e.g. bone mineral content) was obtained by dividing each tibia in 40 partitions. Stiffness and strength in compression were estimated using homogeneous linear elastic microCT-based micro-Finite Element models. Differences between right (irradiated) and left (non-irradiated control) tibiae were evaluated for each parameter. The irradiated tibiae had higher Tb.Th (+3.3%) and Tb.Sp (+11.6%), and lower Tb.N (-14.2%) compared to non-irradiated tibiae, consistently across both strains and intervention groups. A reduction in Tb.BV/TV (-14.9%) was also observed in the C57BL/6 strain. In the OVX group, a small reduction was also observed in Tt.Ar (-5.0%). In conclusion, repeated microCT scans (at 256 mGy, 5 scans, every two weeks) had limited effects on the mouse tibia, compared to the expected changes induced by bone treatments. Therefore, the selected scanning protocol is acceptable for measuring the effect of bone interventions in vivo

    Multimodal pore formation in calcium phosphate cements

    No full text
    Calcium phosphate cements (CPCs) are commonly used as bone substitute materials. However, their slow degradation rate and lack of macroporosity hinders new bone formation. Poly(dl-lactic-co-glycolic acid) (PLGA) incorporation is of great interest as, upon degradation, produces acidic by-products that enhance CPC degradation. Yet, new bone formation is delayed until PLGA degradation occurs a few weeks after implantation. Therefore, the aim of this study was to accelerate the early stage pore formation within CPCs in vitro. With that purpose, we incorporated the water-soluble porogen sucrose at different weight percentages (10 or 20 wt %) to CPC and CPC/PLGA composites. The results revealed that incorporation of sucrose porogens increased mass loss within the first week of in vitro degradation in groups containing sucrose compared to control groups. After week 1, a further mass loss was observed related to PLGA and CPC degradation. Macroporosity analysis confirmed that macroporosity formation is influenced by the dissolution of sucrose at an early stage and by the degradation of PLGA and CPC at a later stage. We concluded that the combination of sucrose and PLGA porogens in CPC is a promising approach to promote early stage bone tissue ingrowth and complete replacement of CPC through multimodal pore formation.</p

    Multimodal pore formation in calcium phosphate cements

    No full text
    Calcium phosphate cements (CPCs) are commonly used as bone substitute materials. However, their slow degradation rate and lack of macroporosity hinders new bone formation. Poly(dl-lactic-co-glycolic acid) (PLGA) incorporation is of great interest as, upon degradation, produces acidic by-products that enhance CPC degradation. Yet, new bone formation is delayed until PLGA degradation occurs a few weeks after implantation. Therefore, the aim of this study was to accelerate the early stage pore formation within CPCs in vitro. With that purpose, we incorporated the water-soluble porogen sucrose at different weight percentages (10 or 20 wt %) to CPC and CPC/PLGA composites. The results revealed that incorporation of sucrose porogens increased mass loss within the first week of in vitro degradation in groups containing sucrose compared to control groups. After week 1, a further mass loss was observed related to PLGA and CPC degradation. Macroporosity analysis confirmed that macroporosity formation is influenced by the dissolution of sucrose at an early stage and by the degradation of PLGA and CPC at a later stage. We concluded that the combination of sucrose and PLGA porogens in CPC is a promising approach to promote early stage bone tissue ingrowth and complete replacement of CPC through multimodal pore formation
    corecore