35 research outputs found

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    Get PDF
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    Passive Q-switching and mode-locking for the generation of nanosecond to femtosecond pulses

    Full text link

    Shared Decision Making in Cardiac Electrophysiology Procedures and Arrhythmia Management

    Get PDF
    Shared decision making (SDM) has been advocated to improve patient care, patient decision acceptance, patient-provider communication, patient motivation, adherence, and patient reported outcomes. Documentation of SDM is endorsed in several society guidelines and is a condition of reimbursement for selected cardiovascular and cardiac arrhythmia procedures. However, many clinicians argue that SDM already occurs with clinical encounter discussions or the process of obtaining informed consent and note the additional imposed workload of using and documenting decision aids without validated tools or evidence that they improve clinical outcomes. In reality, SDM is a process and can be done without decision tools, although the process may be variable. Also, SDM advocates counter that the low-risk process of SDM need not be held to the high bar of demonstrating clinical benefit and that increasing the quality of decision making should be sufficient. Our review leverages a multidisciplinary group of experts in cardiology, cardiac electrophysiology, epidemiology, and SDM, as well as a patient advocate. Our goal is to examine and assess SDM methodology, tools, and available evidence on outcomes in patients with heart rhythm disorders to help determine the value of SDM, assess its possible impact on electrophysiological procedures and cardiac arrhythmia management, better inform regulatory requirements, and identify gaps in knowledge and future needs

    Optimization of the first CUPID detector module

    Get PDF
    CUPID will be a next generation experiment searching for the neutrinoless double ÎČ\beta decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li2_{2} 100^{100}MoO4_4 crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of α\alpha particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 ±\pm 0.2) keV FWHM at the QQ-value of 100^{100}Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an α\alpha particle rejection higher than 99.9%, fully satisfying the requirements for CUPID

    Many Labs 5: Testing Pre-Data-Collection Peer Review as an Intervention to Increase Replicability

    No full text
    Replication studies in psychological science sometimes fail to reproduce prior findings. If these studies use methods that are unfaithful to the original study or ineffective in eliciting the phenomenon of interest, then a failure to replicate may be a failure of the protocol rather than a challenge to the original finding. Formal pre-data-collection peer review by experts may address shortcomings and increase replicability rates. We selected 10 replication studies from the Reproducibility Project: Psychology (RP:P; Open Science Collaboration, 2015) for which the original authors had expressed concerns about the replication designs before data collection; only one of these studies had yielded a statistically significant effect (p lt .05). Commenters suggested that lack of adherence to expert review and low-powered tests were the reasons that most of these RP:P studies failed to replicate the original effects. We revised the replication protocols and received formal peer review prior to conducting new replication studies. We administered the RP:P and revised protocols in multiple laboratories (median number of laboratories per original study = 6.5, range = 3–9; median total sample = 1,279.5, range = 276–3,512) for high-powered tests of each original finding with both protocols. Overall, following the preregistered analysis plan, we found that the revised protocols produced effect sizes similar to those of the RP:P protocols (Δr =.002 or.014, depending on analytic approach). The median effect size for the revised protocols (r =.05) was similar to that of the RP:P protocols (r =.04) and the original RP:P replications (r =.11), and smaller than that of the original studies (r =.37). Analysis of the cumulative evidence across the original studies and the corresponding three replication attempts provided very precise estimates of the 10 tested effects and indicated that their effect sizes (median r =.07, range =.00–.15) were 78% smaller, on average, than the original effect sizes (median r =.37, range =.19–.50)

    Twelve-crystal prototype of Li2_2MoO4_4 scintillating bolometers for CUPID and CROSS experiments

    No full text
    International audienceAn array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied depending on the size of phonon NTD-Ge sensors glued to both LMO and Ge absorbers, shape of the Ge light detectors (circular vs. square, from two suppliers), in different light collection conditions (with and without reflector, with aluminum coated LMO crystal surface). The scintillating bolometer array was operated over 8 months in the low-background conditions that allowed to probe a very low, Ό\muBq/kg, level of the LMO crystals radioactive contamination by 228^{228}Th and 226^{226}Ra

    Toward CUPID-1T

    No full text
    Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay (0ÎœÎČÎČ0\mathrm{\nu\beta\beta}) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass (mÎČÎČm_{\beta\beta}). The next-generation experiments will focus on the sensitivity to the 0ÎœÎČÎČ0\mathrm{\nu\beta\beta} half-life of O(1027\mathcal{O}(10^{27}--102810^{28}~years)) and mÎČÎČâ‰Č15m_{\beta\beta}\lesssim15~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of 0ÎœÎČÎČ0\mathrm{\nu\beta\beta}. We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond 0ÎœÎČÎČ0\mathrm{\nu\beta\beta}, all moving toward the next-to-next generation CUPID-1T detector
    corecore