28,715 research outputs found
Planck pre-launch status: High Frequency Instrument polarization calibration
The High Frequency Instrument of Planck will map the entire sky in the millimeter and sub-millimeter domain from 100 to 857 GHz with unprecedented sensitivity to polarization (ΔP/T_(cmb) ~ 4 × 10^(-6) for P either Q or U and T_(cmb) ≃ 2.7 K) at 100, 143, 217 and 353 GHz. It will lead to major improvements in our understanding of the cosmic microwave background anisotropies and polarized foreground signals. Planck will make high resolution measurements of the E-mode spectrum (up to l ~ 1500) and will also play a prominent role in the search for the faint imprint of primordial gravitational waves on the CMB polarization. This paper addresses the effects of calibration of both temperature (gain) and polarization (polarization efficiency and detector orientation) on polarization measurements. The specific requirements on the polarization parameters of the instrument are set and we report on their pre-flight measurement on HFI bolometers. We present a semi-analytical method that exactly accounts for the scanning strategy of the instrument as well as the combination of different detectors. We use this method to propagate errors through to the CMB angular power spectra in the particular case of Planck-HFI, and to derive constraints on polarization parameters. We show that in order to limit the systematic error to 10% of the cosmic variance of the E-mode power spectrum, uncertainties in gain, polarization efficiency and detector orientation must be below 0.15%, 0.3% and 1° respectively. Pre-launch ground measurements reported in this paper already fulfill these requirements
The conduction pathway of potassium channels is water free under physiological conditions.
Ion conduction through potassium channels is a fundamental process of life. On the basis of crystallographic data, it was originally proposed that potassium ions and water molecules are transported through the selectivity filter in an alternating arrangement, suggesting a "water-mediated" knock-on mechanism. Later on, this view was challenged by results from molecular dynamics simulations that revealed a "direct" knock-on mechanism where ions are in direct contact. Using solid-state nuclear magnetic resonance techniques tailored to characterize the interaction between water molecules and the ion channel, we show here that the selectivity filter of a potassium channel is free of water under physiological conditions. Our results are fully consistent with the direct knock-on mechanism of ion conduction but contradict the previously proposed water-mediated knock-on mechanism
Microplankton species assemblages at the Scripps Pier from March to November 1983 during the 1982-1984 El Nino event
A semiweekly sampling program at the Scripps Institution of Oceanography pier was begun in 1983 during an El Nino event. Microplankton data for March to November 1983 show a temporal sequence of species assemblages of the 24 important taxa, with a residence time of 1 to 4 weeks. From March to early September, the assemblages consisted of typical neritic taxa. From mid-September to mid-November, the presence of oceanic warm-wave species was associated with positive temperature anomalies characteristic of the El Nino condition. During the period studied numerical abundances were low
Measuring Planck beams with planets
Aims. Accurate measurement of the cosmic microwave background (CMB) anisotropy requires precise knowledge of the instrument beam. We explore how well the Planck beams will be determined from observations of planets, developing techniques that are also appropriate for other experiments.
Methods. We simulate planet observations with a Planck-like scanning strategy, telescope beams, noise, and detector properties. Then we employ both parametric and non-parametric techniques, reconstructing beams directly from the time-ordered data. With a faithful parameterization of the beam shape, we can constrain certain detector properties, such as the time constants of the detectors, to high precision. Alternatively, we decompose the beam using an orthogonal basis. For both techniques, we characterize the errors in the beam reconstruction with Monte Carlo realizations. For a simplified scanning strategy, we study the impact on estimation of the CMB power spectrum. Finally, we explore the consequences for measuring cosmological parameters, focusing on the spectral index of primordial scalar perturbations, n_s.
Results. The quality of the power spectrum measurement will be significantly influenced by the optical modeling of the telescope. In our most conservative case, using no information about the optics except the measurement of planets, we find that a single transit of Jupiter across the focal plane will measure the beam window functions to better than 0.3% for the channels at 100–217 GHz that are the most sensitive to the CMB. Constraining the beam with optical modeling can lead to much higher quality reconstruction.
Conclusions. Depending on the optical modeling, the beam errors may be a significant contribution to the measurement systematics for n_s
The adjoint problem in the presence of a deformed surface: the example of the Rosensweig instability on magnetic fluids
The Rosensweig instability is the phenomenon that above a certain threshold
of a vertical magnetic field peaks appear on the free surface of a horizontal
layer of magnetic fluid. In contrast to almost all classical hydrodynamical
systems, the nonlinearities of the Rosensweig instability are entirely
triggered by the properties of a deformed and a priori unknown surface. The
resulting problems in defining an adjoint operator for such nonlinearities are
illustrated. The implications concerning amplitude equations for pattern
forming systems with a deformed surface are discussed.Comment: 11 pages, 1 figur
Bootstrap tomography of high-precision pulses for quantum control
Long-time dynamical decoupling and quantum control of qubits require
high-precision control pulses. Full characterization (quantum tomography) of
imperfect pulses presents a bootstrap problem: tomography requires initial
states of a qubit which can not be prepared without imperfect pulses. We
present a protocol for pulse error analysis, specifically tailored for a wide
range of the single solid-state electron spins. Using a single electron spin of
a nitrogen-vacancy (NV) center in diamond, we experimentally verify the
correctness of the protocol, and demonstrate its usefulness for quantum control
tasks
0.75 atoms improve the clock signal of 10,000 atoms
Since the pioneering work of Ramsey, atom interferometers are employed for
precision metrology, in particular to measure time and to realize the second.
In a classical interferometer, an ensemble of atoms is prepared in one of the
two input states, whereas the second one is left empty. In this case, the
vacuum noise restricts the precision of the interferometer to the standard
quantum limit (SQL). Here, we propose and experimentally demonstrate a novel
clock configuration that surpasses the SQL by squeezing the vacuum in the empty
input state. We create a squeezed vacuum state containing an average of 0.75
atoms to improve the clock sensitivity of 10,000 atoms by 2.05 dB. The SQL
poses a significant limitation for today's microwave fountain clocks, which
serve as the main time reference. We evaluate the major technical limitations
and challenges for devising a next generation of fountain clocks based on
atomic squeezed vacuum.Comment: 9 pages, 6 figure
A calcium ion in a cavity as a controlled single-photon source
We present a single calcium ion, coupled to a high-finesse cavity, as an almost ideal system for the controlled generation of single photons. Photons from a pump beam are Raman-scattered by the ion into the cavity mode, which subsequently emits the photon into a well-defined output channel. In contrast with comparable atomic systems, the ion is localized at a fixed position in the cavity mode for indefinite times, enabling truly continuous operation of the device. We have performed numeric calculations to assess the performance of the system and present the first experimental indication of single-photon emission in our set-up
Experimental Evidence for Efimov Quantum States
Three interacting particles form a system which is well known for its complex
physical behavior. A landmark theoretical result in few-body quantum physics is
Efimov's prediction of a universal set of weakly bound trimer states appearing
for three identical bosons with a resonant two-body interaction. Surprisingly,
these states even exist in the absence of a corresponding two-body bound state
and their precise nature is largely independent of the particular type of the
two-body interaction potential. Efimov's scenario has attracted great interest
in many areas of physics; an experimental test however has not been achieved.
We report the observation of an Efimov resonance in an ultracold thermal gas of
cesium atoms. The resonance occurs in the range of large negative two-body
scattering lengths and arises from the coupling of three free atoms to an
Efimov trimer. We observe its signature as a giant three-body recombination
loss when the strength of the two-body interaction is varied near a Feshbach
resonance. This resonance develops into a continuum resonance at non-zero
collision energies, and we observe a shift of the resonance position as a
function of temperature. We also report on a minimum in the recombination loss
for positive scattering lengths, indicating destructive interference of decay
pathways. Our results confirm central theoretical predictions of Efimov physics
and represent a starting point from which to explore the universal properties
of resonantly interacting few-body systems.Comment: 8 pages, 4 figures, Proceedings of ICAP-2006 (Innsbruck
Sequence learning under uncertainty in children: self-reflection vs. self-assertion
We know that stochastic feedback impairs children's associative stimulus-response (S-R) learning (Crone et al., 2004a; Eppinger et al., 2009), but the impact of stochastic feedback on sequence learning that involves deductive reasoning has not been not tested so far. In the current study, 8- to 11-year-old children (N = 171) learned a sequence of four left and right button presses, LLRR, RRLL, LRLR, RLRL, LRRL, and RLLR, which needed to be deduced from feedback because no directional cues were given. One group of children experienced consistent feedback only (deterministic feedback, 100% correct). In this condition, green feedback on the screen indicated that the children had been right when they were right, and red feedback indicated that the children had been wrong when they were wrong. Another group of children experienced inconsistent feedback (stochastic feedback, 85% correct, 15% false), where in some trials, green feedback on the screen could signal that children were right when in fact they were wrong, and red feedback could indicate that they were wrong when in fact they had been right. Independently of age, children's sequence learning in the stochastic condition was initially much lower than in the deterministic condition, but increased gradually and improved with practice. Responses toward positive vs. negative feedback varied with age. Children were increasingly able to understand that they could have been wrong when feedback indicated they were right (self-reflection), but they remained unable to understand that they could have been right when feedback indicated they were wrong (self-assertion)
- …