87 research outputs found

    Design and commissioning of a thermal stability test-rig for mixtures as working fluids for ORC applications

    Get PDF
    Abstract A novel test-rig for studying the thermal stability of mixtures as working fluids for ORC applications was designed and commissioned at the Laboratory of Compressible-fluid dynamics for Renewable Energy Applications (CREA) of Politecnico di Milano, in collaboration with the University of Brescia. The set-up is a standard one, in which a vessel containing the fluid under scrutiny is placed in a vertical oven for ~ 100 hours at a constant temperature T = Tstress. During the test, the pressure P is monitored to detect thermal decomposition of the fluid. After the test, the vessel is placed in a controlled thermal bath, where the pressure is measured at different value of the temperature T, with

    Design and commissioning of a thermal stability test-rig for mixtures as working fluids for ORC applications

    Get PDF
    A novel test-rig for studying the thermal stability of mixtures as working fluids for ORC applications was designed and commissioned at the Laboratory of Compressible-fluid dynamics for Renewable Energy Applications (CREA) of Politecnico di Milano, in collaboration with the University of Brescia. The set-up is a standard one, in which a vessel containing the fluid under scrutiny is placed in a vertical oven for ~ 100 hours at a constant temperature T = Tstress. During the test, the pressure P is monitored to detect thermal decomposition of the fluid. After the test, the vessel is placed in a controlled thermal bath, where the pressure is measured at different value of the temperature T, with T < Tstress and T < Tc (Tc critical temperature). The resulting isochoric pressure-temperature dependence is compared to that obtained before the fluid underwent thermal stress. If departure from the initial fluid behavior is observed, significant thermal decomposition occurred and a chemical analysis of the decomposition products is carried out using gas chromatography and mass spectroscopy. The novelty of the set-up is the possibility of taking samples of both liquid and vapor phases of the fluid, a capability that was introduced to study thermal decomposition of mixtures, whose composition depends on the pressure and temperature, as well as to capture the more volatile products of thermal decomposition of pure fluids and mixtures. Preliminary experimental results are reported for the pure siloxane fluid MDM (Octamethyltrisiloxane, C8H24O2Si3)

    Favorable Trend of Implantable Cardioverter-Defibrillator Service Life in a Large Single-Nation Population: Insights From 10-Year Analysis of the Italian Implantable Cardioverter-Defibrillator Registry

    Get PDF
    Background: Implantable cardioverter-defibrillators (ICDs) are widely employed for the prevention of sudden cardiac death. Despite technological improvements, patients often need to undergo generator replacement, which entails the risk of periprocedural complications. Our aim was to estimate the service life of ICDs over a 10-year interval and to assess the main causes of replacement on the basis of data from the National ICD Registry of the Italian Society of Arrhythmology and Cardiac Pacing (AIAC). Methods and Results: The registry includes data from over 400 hospitals in Italy. We included all patients who underwent device replacement from calendar years 2007 to 2016. The median service life of the ICDs and its trend over the years was estimated across the 3 types of devices (single-chamber, dual-chamber, cardiac resynchronization therapy defibrillator) and the indication to implantation. The causes of replacement were also analyzed. We included 29&nbsp;158 records from 27&nbsp;676 patients (80.9% men; mean age at device replacement 65.8±12.0&nbsp;years). The median service life was 57.3 months (interquartile range 27.8&nbsp;months). Over the years, service life showed an increasing trend. The majority of patients underwent elective replacement because of battery end of life, and over the years there was a significant reduction of replacement for recalls, erosion/infections, and cardiac resynchronization therapy upgrading. Conclusions: Our data from a large single-nation population showed that the trend of ICD service life, independently from ICD type, indication, and settings, significantly improved over time. Moreover, there was a striking reduction of interventions for upgrading and infection/erosion. This favorable trend has important clinical, organizational, and financial implications

    Treatment of atrial fibrillation with a dual defibrillator in heart failure patients (TRADE HF): protocol for a randomized clinical trial.

    Get PDF
    Background: Heart failure(HF) and atrial fibrillation(AF) frequently coexist in the same patient and are associated with increased mortality and frequent hospitalizations. As the concomitance of AF and HF is often associated with a poor prognosis, the prompt treatment of AF in HF patients may significantly improve outcome.Methods/design: Recent implantable cardiac resynchronization (CRT) devices allow electrical therapies to treat AF automatically. TRADE-HF (trial registration: NCT00345592; http://www.clinicaltrials.gov) is a prospective, randomized, double arm study aimed at demonstrating the efficacy of an automatic, device-based therapy for treatment of atrial tachycardia and fibrillation(AT/AF) in patients indicated for CRT. The study compares automatic electrical therapy to a traditional more usual treatment of AT/AF: the goal is to demonstrate a reduction in a combined endpoint of unplanned hospitalizations for cardiac reasons, death from cardiovascular causes or permanent AF when using automatic atrial therapy as compared to the traditional approach involving hospitalization for symptoms and in-hospital treatment of AT/AF.Discussion: CRT pacemaker with the additional ability to convert AF as well as ventricular arrhythmias may play a simultaneous role in rhythm control and HF treatment. The value of the systematic implantation of CRT ICDs with the capacity to deliver atrial therapy in HF patients at risk of AF has not yet been explored. The TRADE-HF study will assess in CRT patients whether a strategy based on automatic management of atrial arrhythmias might be a valuable option to reduce the number of hospital admission and to reduce the progression the arrhythmia to a permanent for

    The practice of deep sedation in electrophysiology and cardiac pacing laboratories: Results of an italian survey promoted by the aiac (italian association of arrhythmology and cardiac pacing)

    Get PDF
    The aim of this survey, which was open to all Italian cardiologists involved in arrhythmia, was to assess common practice regarding sedation and analgesia in interventional electrophysiology procedures in Italy. The survey consisted of 28 questions regarding the approach to sedation used for elective direct-current cardioversion (DCC), subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation, atrial fibrillation (AF) ablation, ventricular tachycardia (VT) ablation, and transvenous lead extraction procedures. A total of 105 cardiologists from 92 Italian centres took part in the survey. The rate of centres where DCC, S-ICD implantation, AF ablation, VT ablation and lead extraction procedures were performed without anaesthesiologic assistance was 60.9%, 23.6%, 51.2%, 37.3%, and 66.7%, respectively. When these procedures were performed without anaesthesiologic assistance, the drugs (in addition to local anaesthetics) commonly administered were benzodiazepines (from 64.3% to 79.6%), opioids (from 74.4% to 88.1%), and general anaesthetics (from 7.1% to 30.4%). Twenty-three (21.9%) of the 105 cardiologists declared that they routinely administered propofol, without the supervision of an anaesthesiologist, in at least one of the above-mentioned procedures. In current Italian clinical practice, there is a lack of uniformity in the sedation/analgesia approach used in interventional electrophysiology procedures

    Effectiveness of cardiac resynchronization therapy in heart failure patients with valvular heart disease: comparison with patients affected by ischaemic heart disease or dilated cardiomyopathy. The InSync/InSync ICD Italian Registry

    Get PDF
    AimsTo analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients.Methods and resultsPatients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy.ConclusionIn 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available
    corecore