670 research outputs found

    An adaptive space-time phase field formulation for dynamic fracture of brittle shells based on LR NURBS

    Get PDF
    We present an adaptive space-time phase field formulation for dynamic fracture of brittle shells. Their deformation is characterized by the Kirchhoff–Love thin shell theory using a curvilinear surface description. All kinematical objects are defined on the shell’s mid-plane. The evolution equation for the phase field is determined by the minimization of an energy functional based on Griffith’s theory of brittle fracture. Membrane and bending contributions to the fracture process are modeled separately and a thickness integration is established for the latter. The coupled system consists of two nonlinear fourth-order PDEs and all quantities are defined on an evolving two-dimensional manifold. Since the weak form requires C1-continuity, isogeometric shape functions are used. The mesh is adaptively refined based on the phase field using Locally Refinable (LR) NURBS. Time is discretized based on a generalized-α method using adaptive time-stepping, and the discretized coupled system is solved with a monolithic Newton–Raphson scheme. The interaction between surface deformation and crack evolution is demonstrated by several numerical examples showing dynamic crack propagation and branching

    Donnan effect on chloride ion distribution as a determinant of body fluid composition that allows action potentials to spread via fast sodium channels

    Get PDF
    Proteins in any solution with a pH value that differs from their isoelectric point exert both an electric Donnan effect (DE) and colloid osmotic pressure. While the former alters the distribution of ions, the latter forces water diffusion. In cells with highly Cl--permeable membranes, the resting potential is more dependent on the cytoplasmic pH value, which alters the Donnan effect of cell proteins, than on the current action of Na/K pumps. Any weak (positive or negative) electric disturbances of their resting potential are quickly corrected by chloride shifts

    An Intact Kidney Slice Model to Investigate Vasa Recta Properties and Function in situ

    Get PDF
    Background: Medullary blood flow is via vasa recta capillaries, which possess contractile pericytes. In vitro studies using isolated descending vasa recta show that pericytes can constrict/dilate descending vasa recta when vasoactive substances are present. We describe a live kidney slice model in which pericyte-mediated vasa recta constriction/dilation can be visualized in situ. Methods: Confocal microscopy was used to image calcein, propidium iodide and Hoechst labelling in ‘live’ kidney slices, to determine tubular and vascular cell viability and morphology. DIC video-imaging of live kidney slices was employed to investigate pericyte-mediated real-time changes in vasa recta diameter. Results: Pericytes were identified on vasa recta and their morphology and density were characterized in the medulla. Pericyte-mediated changes in vasa recta diameter (10–30%) were evoked in response to bath application of vasoactive agents (norepinephrine, endothelin-1, angiotensin-II and prostaglandin E2) or by manipulating endogenous vasoactive signalling pathways (using tyramine, L-NAME, a cyclo-oxygenase (COX-1) inhibitor indomethacin, and ATP release). Conclusions: The live kidney slice model is a valid complementary technique for investigating vasa recta function in situ and the role of pericytes as regulators of vasa recta diameter. This technique may also be useful in exploring the role of tubulovascular crosstalk in regulation of medullary blood flow

    Sensitivity and Specificity of Multiple Kato-Katz Thick Smears and a Circulating Cathodic Antigen Test for Schistosoma mansoni Diagnosis Pre- and Post-repeated-Praziquantel Treatment

    Get PDF
    Two Kato-Katz thick smears (Kato-Katzs) from a single stool are currently recommended for diagnosing Schistosoma mansoni infections to map areas for intervention. This ‘gold standard’ has low sensitivity at low infection intensities. The urine point-of-care circulating cathodic antigen test (POC-CCA) is potentially more sensitive but how accurately they detect S. mansoni after repeated praziquantel treatments, their suitability for measuring drug efficacy and their correlation with egg counts remain to be fully understood. We compared the accuracies of one to six Kato-Katzs and one POC-CCA for the diagnosis of S. mansoni in primary-school children who have received zero to ten praziquantel treatments. We determined the impact each diagnostic approach may have on monitoring and evaluation (M&E) and drug-efficacy findings

    Examining intra-rater and inter-rater response agreement: A medical chart abstraction study of a community-based asthma care program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To assess the intra- and inter-rater agreement of chart abstractors from multiple sites involved in the evaluation of an Asthma Care Program (ACP).</p> <p>Methods</p> <p>For intra-rater agreement, 110 charts randomly selected from 1,433 patients enrolled in the ACP across eight Ontario communities were re-abstracted by 10 abstractors. For inter-rater agreement, data abstractors reviewed a set of eight fictitious charts. Data abstraction involved information pertaining to six categories: physical assessment, asthma control, spirometry, asthma education, referral visits, and medication side effects. Percentage agreement and the kappa statistic (κ) were used to measure agreement. Sensitivity and specificity estimates were calculated comparing results from all raters against the gold standard.</p> <p>Results</p> <p>Intra-rater re-abstraction yielded an overall kappa of 0.81. Kappa values for the chart abstraction categories were: physical assessment (κ 0.84), asthma control (κ 0.83), spirometry (κ 0.84), asthma education (κ 0.72), referral visits (κ 0.59) and medication side effects (κ 0.51). Inter-rater abstraction of the fictitious charts produced an overall kappa of 0.75, sensitivity of 0.91 and specificity of 0.89. Abstractors demonstrated agreement for physical assessment (κ 0.88, sensitivity and specificity 0.95), asthma control (κ 0.68, sensitivity 0.89, specificity 0.85), referral visits (κ 0.77, sensitivity 0.88, specificity 0.95), and asthma education (κ 0.49, sensitivity 0.87, specificity 0.77).</p> <p>Conclusion</p> <p>Though collected by multiple abstractors, the results show high sensitivity and specificity and substantial to excellent inter- and intra-rater agreement, assuring confidence in the use of chart abstraction for evaluating the ACP.</p

    Childbirth experience questionnaire: validating its use in the United Kingdom

    Get PDF
    BACKGROUND: The Childbirth Experience Questionnaire (CEQ) was developed in Sweden in 2010 and validated in 920 primiparous women. It has not been validated in the United Kingdom (UK). Measuring the impact of an intervention on a woman's childbirth experience is arguably as important as measuring its impact on outcomes such as caesarean delivery and perinatal morbidity or mortality and yet surprisingly it is rarely done. The lack of a robust validated tool for evaluating labour experience in the UK is a topical issue in the UK at present. Indeed NICE say 'A standardised method to measure and quantify women's psychological and emotional wellbeing and their birth experiences is urgently required to support any study investigating the effectiveness of interventions, techniques or strategies during birth.' METHODS: The Childbirth Experience Questionnaire and part of the Care Quality Commission Maternity Survey (2010) was sent to 350 women at one month postnatal. The CEQ was sent again two weeks later. The CEQ was tested for face validity among 25 postnatal mothers. Demographic data and delivery data was used to establish construct validity of the CEQ using the method of known-groups validation. The results of the scored CEQ sent out twice were used to measure test-retest reliability of the CEQ by calculating the quadratic weighted index of agreement between the two scores. Criterion validity was measured by calculating the Pearson correlation coefficient for the CEQ and Maternity Survey scores. RESULTS: Face validity of the CEQ in a UK population was demonstrated with all respondents stating it was easy to understand and complete. A statistically significantly higher CEQ score for subgroups of women known to report a better birth outcome demonstrated construct validity of the CEQ. A weighted kappa of 0.68 demonstrated test-retest reliability of the CEQ. A Pearson correlation co-efficient of 0.73 demonstrated a strong correlation between the results of the CEQ and the results of the 'gold standard' assessment of childbirth experience in the UK: the Maternity Survey and hence criterion validity of the CEQ. CONCLUSIONS: The Childbirth Experience Questionnaire is a valid and reliable measure of childbirth experience in the UK population

    A renewable tissue resource of phenotypically stable, biologically and ethnically diverse, patient-derived human breast cancer xenograft models.

    Get PDF
    Breast cancer research is hampered by difficulties in obtaining and studying primary human breast tissue, and by the lack of in vivo preclinical models that reflect patient tumor biology accurately. To overcome these limitations, we propagated a cohort of human breast tumors grown in the epithelium-free mammary fat pad of severe combined immunodeficient (SCID)/Beige and nonobese diabetic (NOD)/SCID/IL-2γ-receptor null (NSG) mice under a series of transplant conditions. Both models yielded stably transplantable xenografts at comparably high rates (∼21% and ∼19%, respectively). Of the conditions tested, xenograft take rate was highest in the presence of a low-dose estradiol pellet. Overall, 32 stably transplantable xenograft lines were established, representing 25 unique patients. Most tumors yielding xenografts were "triple-negative" [estrogen receptor (ER)-progesterone receptor (PR)-HER2+; n = 19]. However, we established lines from 3 ER-PR-HER2+ tumors, one ER+PR-HER2-, one ER+PR+HER2-, and one "triple-positive" (ER+PR+HER2+) tumor. Serially passaged xenografts show biologic consistency with the tumor of origin, are phenotypically stable across multiple transplant generations at the histologic, transcriptomic, proteomic, and genomic levels, and show comparable treatment responses as those observed clinically. Xenografts representing 12 patients, including 2 ER+ lines, showed metastasis to the mouse lung. These models thus serve as a renewable, quality-controlled tissue resource for preclinical studies investigating treatment response and metastasis

    Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position.</p> <p>Aims</p> <p>To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods.</p> <p>Study design</p> <p>Retrospective study.</p> <p>Methods</p> <p>25 consecutive patients with adolescent idiopathic scoliosis scheduled for surgery (17 girls, 8 boys) aged 15 ± 2 years (mean ± SD) were included in the analysis of this study. The degree of the vertebral rotation was in all patients measured according to the method of Perdriolle on standing plain radiographs and on supine CT scanogram, and according to the method of Aaro and Dahlborn on axial CT images in prone position and on magnetic resonance imaging (MRI) in supine position. The measurements were done by one neuroradiologist at two different occasions. Bland and Altman statistical approach was used in the reliability assessment.</p> <p>Results</p> <p>The reliability of measuring vertebral rotation by axial CT images in prone position was almost perfect with an intraclass correlation coefficient of 0.95, a random error of the intraobserver differences of 2.3°, a repeatability coefficient of 3.2° and a coefficient of variation of 18.4%. Corresponding values for measurements on CT scanogram were 0.83, 5.1°, 7.2°, and 32.8%, respectively, indicating lower reliability of the latter modality and method. The degree of vertebral rotation measured on standing plain radiographs, prone CT scanogram, axial images on CT in prone position and on MRI in supine position were 25.7 ± 9.8°, 21.9 ± 8.3°, 17.4 ± 7.1°, and 16.1 ± 6.5°, respectively. The vertebral rotation measured on axial CT images in prone position was in average 7.5% larger than that measured on axial MRI in supine position.</p> <p>Conclusions</p> <p>This study has shown that measurements of vertebral rotation in prone position were more reliable on axial CT images than on CT scanogram. The measurement of vertebral rotation on CT (corrected to the pelvic tilt) in prone position imposes lower impact of the recumbent position on the vertebral rotation than did MRI in supine position. However, the magnitude of differences is of doubtful clinical significance.</p
    corecore