413 research outputs found
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.Comment: 19 pages, 14 figures. Minor corrections, matches published version in
JINS
Measurement of the electron drift velocity for directional dark matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : and . We also show that adding allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.Comment: Proceedings of the 4th international conference on Directional
Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa
Trigger and readout electronics for the STEREO experiment
The STEREO experiment will search for a sterile neutrino by measuring the
anti-neutrino energy spectrum as a function of the distance from the source,
the ILL nuclear reactor. A dedicated electronic system, hosted in a single
microTCA crate, was designed for this experiment. It performs triggering in two
stages with various selectable conditions, processing and readout via UDP/IPBUS
of 68 photomultiplier signals continuously digitized at 250 MSPS. Additionally,
for detector performance monitoring, the electronics allow on-line calibration
by driving LED synchronously with the data acquisition. This paper describes
the electronics requirements, architecture and the performances achieved.Comment: Topical Workshop on Electronics for Particle Physics (TWEPP) 2015,
Lisboa. 9 pages, 9 figure
Probing neutron-hidden neutron transitions with the MURMUR experiment
MURMUR is a new passing-through-walls neutron experiment designed to
constrain neutron/hidden neutron transitions allowed in the context of
braneworld scenarios or mirror matter models. A nuclear reactor can act as a
hidden neutron source, such that neutrons travel through a hidden world or
sector. Hidden neutrons can propagate out of the nuclear core and far beyond
the biological shielding. However, hidden neutrons can weakly interact with
usual matter, making possible for their detection in the context of low-noise
measurements. In the present work, the novelty rests on a better background
discrimination and the use of a mass of a material - here lead - able to
enhance regeneration of hidden neutrons into visible ones to improve detection.
The input of this new setup is studied using both modelizations and
experiments, thanks to tests currently performed with the experiment at the BR2
research nuclear reactor (SCKCEN, Mol, Belgium). A new limit on the
neutron swapping probability p has been derived thanks to the measurements
taken during the BR2 Cycle 02/2019A: at 95% CL.
This constraint is better than the bound from the previous passing-through-wall
neutron experiment made at ILL in 2015, despite BR2 is less efficient to
generate hidden neutrons by a factor 7.4, thus raising the interest of such
experiment using regenerating materials.Comment: 15 pages, 8 figures, final version, accepted for publication in
European Physical Journal
MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection
Directional detection of non-baryonic Dark Matter is a promising search
strategy for discriminating WIMP events from neutrons, the ultimate background
for dark matter direct detection. This strategy requires both a precise
measurement of the energy down to a few keV and 3D reconstruction of tracks
down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has
developed in the last years an original prototype detector based on the direct
coupling of large pixelized micromegas with a special developed fast
self-triggered electronics showing the feasibility of a new generation of
directional detectors. The first bi-chamber prototype has been installed at
Modane, underground laboratory in June 2012. The first undergournd background
events, the gain stability and calibration are shown. The first spectrum of
nuclear recoils showing 3D tracks coming from the radon progeny is presented.Comment: Proceedings of the 4th International Conference on Directional Dark
Matter Detection CYGNUS2013, held in Toyoma (Japan), June 201
Limits on the neutrino magnetic moment from the MUNU experiment
The MUNU experiment was carried out at the Bugey nuclear power reactor. The
aim was the study of electron antineutrino-electron elastic scattering at low
energy. The recoil electrons were recorded in a gas time projection chamber,
immersed in a tank filled with liquid scintillator serving as veto detector,
suppressing in particular Compton electrons. The measured electron recoil
spectrum is presented. Upper limits on the neutrino magnetic moment were
derived and are discussed.Comment: 9 pages, 7 figures Added reference: p.3, 1st col., TEXONO Added
sentence: p.4, 1st col., electron attachement Modified sentence: p.5, 1st
col., readout sequence Added sentence: p.5, 1st col., fast rise time cu
Sub MeV Particles Detection and Identification in the MUNU detector ((1)ISN, IN2P3/CNRS-UJF, Grenoble, France, (2)Institut de Physique, Neuch\^atel, Switzerland, (3) INFN, Padova Italy, (4) Physik-Institut, Z\"{u}rich, Switzerland)
We report on the performance of a 1 m TPC filled with CF at 3
bar, immersed in liquid scintillator and viewed by photomultipliers. Particle
detection, event identification and localization achieved by measuring both the
current signal and the scintillation light are presented. Particular features
of particle detection are also discussed. Finally, the Mn
photopeak, reconstructed from the Compton scattering and recoil angle is shown.Comment: Latex, 19 pages, 20 figure
Optimization of laser capture microdissection and RNA amplification for gene expression profiling of prostate cancer
BACKGROUND: To discover prostate cancer biomarkers, we profiled gene expression in benign and malignant cells laser capture microdissected (LCM) from prostate tissues and metastatic prostatic adenocarcinomas. Here we present methods developed, optimized, and validated to obtain high quality gene expression data. RESULTS: RNase inhibitor was included in solutions used to stain frozen tissue sections for LCM, which improved RNA quality significantly. Quantitative PCR assays, requiring minimal amounts of LCM RNA, were developed to determine RNA quality and concentration. SuperScript II™ reverse transcriptase was replaced with SuperScript III™, and SpeedVac concentration was eliminated to optimize linear amplification. The GeneChip(® )IVT labeling kit was used rather than the Enzo BioArray™ HighYield™ RNA transcript labeling kit since side-by-side comparisons indicated high-end signal saturation with the latter. We obtained 72 μg of labeled complementary RNA on average after linear amplification of about 2 ng of total RNA. CONCLUSION: Unsupervised clustering placed 5/5 normal and 2/2 benign prostatic hyperplasia cases in one group, 5/7 Gleason pattern 3 cases in another group, and the remaining 2/7 pattern 3 cases in a third group with 8/8 Gleason pattern 5 cases and 3/3 metastatic prostatic adenocarcinomas. Differential expression of alpha-methylacyl coenzyme A racemase (AMACR) and hepsin was confirmed using quantitative PCR
- …