41 research outputs found

    Experimental comparison of autodyne and heterodyne laser interferometry using a Nd:YVO4 microchip laser

    Full text link
    Using a Nd:YVO4 microchip laser with a relaxation frequency in the megahertz range, we have experimentally compared a heterodyne interferometer based on a Michelson configuration with an autodyne interferometer based on the laser optical feedback imaging (LOFI) method regarding their signal to noise ratios. In the heterodyne configuration, the beating between the reference beam and the signal beam is realized outside the laser cavity while in the autodyne configuration, the wave beating takes place inside the laser cavity and the relaxation oscillations of the laser intensity then play an important part. For a given laser output power, object under investigation and detection noise level, we have determined the amplification gain of the LOFI interferometer compared to the heterodyne interferometer. LOFI interferometry is demonstrated to show higher performances than heterodyne interferometry for a wide range of laser power and detection level of noise. The experimental results are in good agreement with the theoretical predictions

    Nonlinear modification of the laser noise power spectrum induced by a frequency-shifted optical feedback

    Full text link
    In this article, we study the non-linear coupling between the stationary (i.e. the beating modulation signal) and transient (i.e. the laser quantum noise) dynamics of a laser subjected to frequency shifted optical feedback. We show how the noise power spectrum and more specifically the relaxation oscillation frequency of the laser are modified under different optical feedback condition. Specifically we study the influence of (i) the amount of light returning to the laser cavity and (ii) the initial detuning between the frequency shift and intrinsic relaxation frequency. The present work shows how the relaxation frequency is related to the strength of the beating signal and the shape of the noise power spectrum gives an image of the Transfer Modulation Function (i.e. of the amplification gain) of the nonlinear-laser dynamics.The theoretical predictions, confirmed by numerical resolutions, are in good agreements with the experimental data.Comment: in Physical Review, American Physical Society (APS), 201

    Sensitivity of synthetic aperture laser optical feedback imaging

    Full text link
    In this paper we compare the sensitivity of two imaging configurations both based on Laser Optical Feedback Imaging (LOFI). The first one is direct imaging, which uses conventional optical focalisation on target and the second one is made by Synthetic Aperture (SA) Laser, which uses numerical focalisation. We show that SA configuration allows to obtain good resolutions with high working distance and that the drawback of SA imagery is that it has a worse photometric balance in comparison to conventional microscope. This drawback is partially compensated by the important sensitivity of LOFI. Another interest of SA relies on the capacity of getting a 3D information in a single x-y scan

    Deep and optically resolved imaging through scattering media by space-reversed propagation

    Full text link
    We propose a novel technique of microscopy to overcome the effects of both scattering and limitation of the accessible depth due to the objective working distance. By combining Laser Optical Feedback Imaging (LOFI) with Acoustic Photon Taging (APT) and Synthetic Aperture (SA) refocusing we demonstrate an ultimate shot noise sensitivity at low power (required to preserve the tissues) and a high resolution beyond the microscope working distance. More precisely, with a laser power of 10mW, we obtain images with a micrometric resolution over ~8 transport mean free paths, corresponding to 1.3 times the microscope working distance. Various applications such as biomedical diagnosis, research and development of new drugs and therapies can benefit from our imaging setup

    Coherent microscopy by laser optical feedback imaging (LOFI) technique

    Full text link
    The application of the non conventional imaging technique LOFI (Laser Optical Feedback Imaging) to coherent microscopy is presented. This simple and efficient technique using frequency-shifted optical feedback needs the sample to be scanned in order to obtain an image. The effects on magnitude and phase signals such as vignetting and field curvature occasioned by the scanning with galvanometric mirrors are discussed. A simple monitoring method based on phase images is proposed to find the optimal position of the scanner. Finally, some experimental results illustrating this technique are presented

    Self-aligned setup for laser optical feedback imaging insensitive to parasitic optical feedback

    No full text
    International audienceIn this paper we propose a new optical architecture for the laser optical feedback imaging (LOFI) technique which makes it possible to avoid the adverse effect of the optical parasitic backscattering introduced by all the optical interfaces located between the laser source and the studied object. This proposed setup need no specific or complex alignment, that why we can consider the proposed setup as self aligned. We describe the principle used to avoid the parasitic backscattering contributions which deteriorate dramatically amplitude and phase information contained in the LOFI images. Finally, we give successful demonstration of amplitude and phase images obtained with this self aligned setup in presence of a parasitic reflection

    Dynamical amplification of phase conjugation using a modulated optical feedback in a Nd:YVO_4 laser

    Get PDF
    International audienceWe demonstrate an efficient dynamical amplification of phase conjugation in the gain medium of a diode-pumped Nd3+:YVO4 solid state laser via excitation of its relaxation oscillations. Consequently, enhancement in the modulated amplitude of the phase conjugate wave is observed with up to +30 dB compared to classical homodyne approach

    Limitations of synthetic aperture laser optical feedback imaging

    Full text link
    In this paper we study the origin and the effect of amplitude and phase noise on Laser Optical Feedback Imaging (LOFI) associated with Synthetic Aperture (SA) imaging system. Amplitude noise corresponds to photon noise and acts as an additive noise, it can be reduced by increasing the global measurement time. Phase noise can be divided in three families: random, sinusoidal and drift phase noise; we show that it acts as a multiplicative noise. We explain how we can reduce phase noise by making oversampling or multiple measurements depending on its type. This work can easily be extended to all SA systems (Radar, Laser or Terahertz), especially when raw holograms are acquired point by point
    corecore