400 research outputs found

    Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

    Get PDF

    Search for invisible modes of nucleon decay in water with the SNO+ detector

    Get PDF
    This paper reports results from a search for nucleon decay through invisible modes, where no visible energy is directly deposited during the decay itself, during the initial water phase of SNO+. However, such decays within the oxygen nucleus would produce an excited daughter that would subsequently deexcite, often emitting detectable gamma rays. A search for such gamma rays yields limits of 2.5×1029  y at 90% Bayesian credibility level (with a prior uniform in rate) for the partial lifetime of the neutron, and 3.6×1029  y for the partial lifetime of the proton, the latter a 70% improvement on the previous limit from SNO. We also present partial lifetime limits for invisible dinucleon modes of 1.3×1028  y for nn, 2.6×1028  y for pn and 4.7×1028  y for pp, an improvement over existing limits by close to 3 orders of magnitude for the latter two

    Magnetic-field measurement and analysis for the Muon g − 2 Experiment at Fermilab

    Get PDF
    The Fermi National Accelerator Laboratory (FNAL) Muon g - 2 Experiment has measured the anomalous precession frequency a_{ÎŒ}(g_{ÎŒ} - 2)/2 of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7C. The measured field is weighted by the muon distribution resulting in \tilde{ω}'_{p}, the denominator in the ratio \tilde{ω}_{a}/\tilde{ω}'_{p} that together with known fundamental constants yields aÎŒ. The reported uncertainty on \tilde{ω}'_{p} for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb

    Measurement of the positive muon anomalous magnetic moment to 0.20 ppm

    Get PDF

    Search for a vector-like quark Tâ€Č → tH via the diphoton decay mode of the Higgs boson in proton-proton collisions at s \sqrt{s} = 13 TeV

    Get PDF
    A search for the electroweak production of a vector-like quark Tâ€Č, decaying to a top quark and a Higgs boson is presented. The search is based on a sample of proton-proton collision events recorded at the LHC at = 13 TeV, corresponding to an integrated luminosity of 138 fb−1. This is the first Tâ€Č search that exploits the Higgs boson decay to a pair of photons. For narrow isospin singlet Tâ€Č states with masses up to 1.1 TeV, the excellent diphoton invariant mass resolution of 1–2% results in an increased sensitivity compared to previous searches based on the same production mechanism. The electroweak production of a Tâ€Č quark with mass up to 960 GeV is excluded at 95% confidence level, assuming a coupling strength ÎșT = 0.25 and a relative decay width Γ/MTâ€Č < 5%

    Evidence for four-top quark production in proton-proton collisions at √s = 13 TeV

    Get PDF

    Measurement of the B0^{0}s_{s} → ÎŒ+^{+} Ό−^{-} decay properties and search for the B0^{0} → ÎŒ+^{+}Ό−^{-} decay in proton-proton collisions at √s = 13 TeV

    Get PDF

    Search for top squarks in the four-body decay mode with single lepton final states in proton-proton collisions at s \sqrt{s} = 13 TeV

    Get PDF
    A search for the pair production of the lightest supersymmetric partner of the top quark, the top squark (t∌1), is presented. The search targets the four-body decay of the t∌1, which is preferred when the mass difference between the top squark and the lightest supersymmetric particle is smaller than the mass of the W boson. This decay mode consists of a bottom quark, two other fermions, and the lightest neutralino (χ∌01), which is assumed to be the lightest supersymmetric particle. The data correspond to an integrated luminosity of 138 fb−1 of proton-proton collisions at a center-of-mass energy of 13 TeV collected by the CMS experiment at the CERN LHC. Events are selected using the presence of a high-momentum jet, an electron or muon with low transverse momentum, and a significant missing transverse momentum. The signal is selected based on a multivariate approach that is optimized for the difference between m(t∌1) and m(χ∌01). The contribution from leading background processes is estimated from data. No significant excess is observed above the expectation from standard model processes. The results of this search exclude top squarks at 95% confidence level for masses up to 480 and 700 GeV for m(t∌1) − m(χ∌01) = 10 and 80 GeV, respectively

    Measurement of the cross section of top quark-antiquark pair production in association with a W boson in proton-proton collisions at s \sqrt{s} = 13 TeV

    Get PDF
    The production of a top quark-antiquark pair in association with a W boson (ttˉW)(t\bar{t}W) is measured in proton-proton collisions at a center-of-mass energy of 13 TeV. The analyzed data was recorded by the CMS experiment at the CERN LHC and corresponds to an integrated luminosity of 138 fb−1^{−1}. Events with two or three leptons (electrons and muons) and additional jets are selected. In events with two leptons, a multiclass neural network is used to distinguish between the signal and background processes. Events with three leptons are categorized based on the number of jets and of jets originating from b quark hadronization, and the lepton charges. The inclusive (ttˉW)(t\bar{t}W) production cross section in the full phase space is measured to be 868 ± 40(stat) ± 51(syst) fb. The (ttˉW)+(t\bar{t}W)+ and (ttˉW)−(t\bar{t}W)− cross sections are also measured as 553 ± 30(stat) ± 30(syst) and 343 ± 26(stat) ± 25(syst) fb, respectively, and the corresponding ratio of the two cross sections is found to be 1.61±0.15(stat)−0.05+0.07^{+0.07}_{−0.05}(syst). The measured cross sections are larger than but consistent with the standard model predictions within two standard deviations, and represent the most precise measurement of these cross sections to date
    • 

    corecore