3,416 research outputs found

    Ensemble of Hankel Matrices for Face Emotion Recognition

    Full text link
    In this paper, a face emotion is considered as the result of the composition of multiple concurrent signals, each corresponding to the movements of a specific facial muscle. These concurrent signals are represented by means of a set of multi-scale appearance features that might be correlated with one or more concurrent signals. The extraction of these appearance features from a sequence of face images yields to a set of time series. This paper proposes to use the dynamics regulating each appearance feature time series to recognize among different face emotions. To this purpose, an ensemble of Hankel matrices corresponding to the extracted time series is used for emotion classification within a framework that combines nearest neighbor and a majority vote schema. Experimental results on a public available dataset shows that the adopted representation is promising and yields state-of-the-art accuracy in emotion classification.Comment: Paper to appear in Proc. of ICIAP 2015. arXiv admin note: text overlap with arXiv:1506.0500

    Evaluation of Magnetic Micro- and Nanoparticle Toxicity to Ocular Tissues

    Get PDF
    Purpose: Magnetic nanoparticles (MNPs) may be used for focal delivery of plasmids, drugs, cells, and other applications. Here we ask whether such particles are toxic to ocular structures. Methods: To evaluate the ocular toxicity of MNPs, we asked if either 50 nm or 4 mm magnetic particles affect intraocular pressure, corneal endothelial cell count, retinal morphology including both cell counts and glial activation, or photoreceptor function at different time points after injection. Sprague-Dawley rats (n = 44) were injected in the left eye with either 50 nm (3 ml, 1.65 mg) or 4 mm(3ml, 1.69 mg) magnetic particles, and an equal volume of PBS into the right eye. Electroretinograms (ERG) were used to determine if MNPs induce functional changes to the photoreceptor layers. Enucleated eyes were sectioned for histology and immunofluorescence. Results: Compared to control-injected eyes, MNPs did not alter IOP measurements. ERG amplitudes for a-waves were in the 100–250 mV range and b-waves were in the 500–600 mV range, with no significant differences between injected and noninjected eyes. Histological sectioning and immunofluorescence staining showed little difference in MNP-injected animals compared to control eyes. In contrast, at 1 week, corneal endothelial cell numbers were significantly lower in the 4 mm magnetic particle-injected eyes compared to either 50 nm MNP- or PBS-injected eyes. Furthermore, iron deposition was detected after 4 mm magnetic particle but not 50 nm MNP injection

    Study of the a_0(980) meson via the radiative decay phi->eta pi^0 gamma with the KLOE detector

    Full text link
    We have studied the phi->a_0(980) gamma process with the KLOE detector at the Frascati phi-factory DAPhNE by detecting the phi->eta pi^0 gamma decays in the final states with eta->gamma gamma and eta->pi^+ pi^- pi^0. We have measured the branching ratios for both final states: Br(phi->eta pi^0 gamma)=(7.01 +/- 0.10 +/- 0.20)x10^-5 and (7.12 +/- 0.13 +/- 0.22)x10^-5 respectively. We have also extracted the a_0(980) mass and its couplings to eta pi^0, K^+ K^-, and to the phi meson from the fit of the eta pi^0 invariant mass distributions using different phenomenological models.Comment: 17 pages, 6 figures, submitted to Physics Letters B. Corrected typos in eq.
    • …
    corecore