3,664 research outputs found

    Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector

    Get PDF
    The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2stat±0.4sys)×103(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}~events~keVee1_{ee}^{-1}~kg1^{-1}~day1^{-1} in a 118~kg fiducial volume. The observed background rate is (3.6±0.4stat)×103(3.6\pm0.4_{\textrm{stat}})\times10^{-3}~events~keVee1_{ee}^{-1}~kg1^{-1}~day1^{-1}, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.Comment: 18 pages, 12 figures / 17 images, submitted to Astropart. Phy

    Studies of correlations between D and Dˉ{\bar D} mesons in high energy photoproduction

    Get PDF
    Studies of DDˉD{\bar D} correlations for a large sample of events containing fully and partially reconstructed pairs of charmed DD mesons recorded by the Fermilab photoproduction experiment FOCUS (FNAL-E831) are presented. Correlations between DD and Dˉ{\bar D} mesons are used to study heavy quark production dynamics. We present results for fully and partially reconstructed charm pairs and comparisons to a recent version of \textsc{Pythia} with default parameter settings. We also comment on the production of ψ(3770)\psi(3770) in our data.Comment: 14 pages, 4 figure

    After LUX: The LZ Program

    Full text link
    The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.Comment: Conference proceedings from APS DPF 2011. 9 pages, 6 figure
    corecore