47 research outputs found

    Filters for X-ray detectors on Space missions

    Full text link
    Thin filters and gas tight windows are used in Space to protect sensitive X-ray detectors from out-of-band electromagnetic radiation, low-energy particles, and molecular contamination. Though very thin and made of light materials, filters are not fully transparent to X-rays. For this reason, they ultimately define the detector quantum efficiency at low energies. In this chapter, we initially provide a brief overview of filter materials and specific designs adopted on space experiments with main focus on detectors operating at the focal plane of grazing incidence X-ray telescopes. We then provide a series of inputs driving the design and development of filters for high-energy astrophysics space missions. We begin with the identification of the main functional goals and requirements driving the preliminary design, and identify modeling tools and experimental characterization techniques needed to prove the technology and consolidate the design. Finally, we describe the calibration activities required to derive the filter response with high accuracy.We conclude with some hints on materials and technologies presently under investigation for future X-ray missions.Comment: 45 pages, 11 figures Contribution to the Handbook of X-ray and Gamma-ray Astrophysics in the chapter "Detectors for X-ray Astrophysics", edited by Jan-Willem den Herder, Norbert Meidinger, Marco Feroc

    Elastic characterization of nanometer-thick polymeric film for astrophysics application with an experimental-numerical method

    Get PDF
    The x-ray detectors on board astrophysics space missions require optical blocking filters that are highly transparent to x-rays. The filter design typically consists of a polymeric film that is a few tens of nanometers thick coated with aluminium. Due to the large size of the filter membrane (from a few tens to a few hundred square centimeters) and the extreme aspect ratio, together with severe loading conditions during launch and different stoichiometries of the polymer that could change its mechanical properties, a characterization study of the employed material is needed. The plane strain bulge test is a well-accepted methodology for the mechanical testing of structures that are less than a micrometer thick, and especially for freestanding membranes. Unfortunately, testing such ultra-thin films is not a simple task due to residual stress and experimental uncertainty at very low pressure. In this work, the elastic properties of an extremely thin (between 45 and 415 nm) membrane made of bare polyimide and coated with aluminium were derived through adopting a combined experimental-numerical methodology based on the bulge test and numerical simulations

    Deformation analysis of ATHENA test filters made of plastic thin films supported by a mesh under differential static pressure

    Get PDF
    Within ESA Cosmic Vision 2015-2025 Science Program, ATHENA was selected to be a Large-class high energy astrophysics space mission. The observatory will be equipped with two interchangeable focal plane detectors named X-Ray Integral Field Unit (X-IFU) and Wide Field Imager (WFI). In order to optimally exploit the detector sensitivity, X-ray transparent filters are required. Such filters need to be extremely thin to maximize the X-ray transparency, that is, no more than a few tens of nm, still they must be able to sustain the severe stresses experienced during launch. Partially representative test filters were made with a thin polypropylene film, coated with Ti, and supported by a thin highly transparent mesh either in stainless steel or niobium. Differential static pressure experiments were carried out on two filter samples. In addition, the roles of the mesh on the mechanical deformation is studied, adopting a finite element model (FEM). The numerical analysis is compared with experimental results and found in good agreement. The FEM is a promising tool that allows to characterize materials and thicknesses in order to optimize the design

    A kite balloon system for the monitoring of gatherings in open areas

    Get PDF
    To fight the diffusion of COVID-19, INAF-OAPA proposes an innovative prototype of a static aerial platform for observations from a certain quote. The technology, developed in the field of surveillance for public safety, environmental monitoring, such as illegal landfills, traffic, smog, fires and for precision agriculture, can be fruitfully migrated to other fields such as open areas monitoring, to identify large gatherings of people outdoors

    The thin and medium filters of the EPIC camera on-board XMM-Newton: measured performance after more than 15 years of operation

    Get PDF
    After more than 15 years of operation of the EPIC camera on board the XMM-Newton X-ray observatory, we have reviewed the status of its Thin and Medium filters. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, Raman scattering, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. Furthermore, we have investigated the status of the EPIC flight filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission. We both investigated repeated observations of single optically bright targets and performed a statistical analysis of the extent of loading versus visual magnitude at different epochs. We report the results of the measurements conducted up to now. Most notably, we find no evidence for change in the UV/VIS transmission of the back-up filters in ground tests spanning a 2 year period and we find no evidence for change in the optical transmission of the thin filter of the EPIC-pn camera from 2002 to 2012. We point out some lessons learned for the development and calibration programs of filters for X-ray detectors in future Astronomy missions

    INAF Raggruppamento Scientifico Nazionale 5 - Forum delle Tecnologie 2022

    Get PDF
    Il CSN5, rispondendo alle esigenze di creare maggiori occasioni di dialogo e di networking e di mettere a fattor comune le esperienze maturate in settori strategici del nostro Ente, ha organizzato il primo “Forum della Ricerca Sperimentale e Tecnologica INAF” che si è svolto presso l’area di ricerca di Bologna nei giorni 22, 23 e 24 giugno 2022. L'evento aveva diversi obiettivi: - incrementare la reciproca conoscenza delle attività tecnologiche condotte nelle diverse strutture INAF; - favorire discussioni, scambi, sinergie; - promuovere il senso di appartenenza alla comunità INAF; - introdurre e coinvolgere il personale assunto negli ultimi anni, che non dispone di una visione di insieme di tutte le attività svolte dall’INAF; - stimolare le collaborazioni, anche al di fuori dei rapporti già esistenti; - far emergere eventuali problematiche, discuterne insieme ed individuare possibili soluzioni; - in generale, migliorare la capacità dell’Ente nel realizzare strumentazione sempre più sofisticata e complessa

    Manufacturing and testing a thin glass mirror shell with piezoelectric active control

    Get PDF
    Optics for future X-ray telescopes will be characterized by very large aperture and focal length, and will be made of lightweight materials like glass or silicon in order to keep the total mass within acceptable limits. Optical modules based on thin slumped glass foils are being developed at various institutes, aiming at improving the angular resolution to a few arcsec HEW. Thin mirrors are prone to deform, so they require a careful integration to avoid deformations and even correct forming errors. On the other hand, this offers the opportunity to actively correct the residual deformation: a viable possibility to improve the mirror figure is the application of piezoelectric actuators onto the non-optical side of the mirrors, and several groups are already at work on this approach. The concept we are developing consists of actively integrating thin glass foils with piezoelectric patches, fed by voltages driven by the feedback provided by X-rays. The actuators are commercial components, while the tension signals are carried by a printed circuit obtained by photolithography, and the driving electronic is a multi-channel low power consumption voltage supply developed inhouse. Finally, the shape detection and the consequent voltage signal to be provided to the piezoelectric array are determined in X-rays, in intra-focal setup at the XACT facility at INAF/OAPA. In this work, we describe the manufacturing steps to obtain a first active mirror prototype and the very first test performed in X-rays
    corecore