391 research outputs found

    A taxonomy of critical factors towards Sustainable Operations and Supply Chain Management 4.0 in developing countries– A systematic review and fuzzy group decision-making

    Get PDF
    Supply chain disruptions, intensified by black swan events such as the COVID-19 pandemic and the Russia-Ukraine war, have increased the interest in resilient supply chains, which can be achieved by adopting sustainable Industry 4.0 (I4.0) practices. However, the critical success factors (CSFs) for sustainable I4.0 in operations and supply chain management (S-OSCM4.0) are unclear, and there is a lack of a holistic and empirically validated taxonomy of CSFs from multiple stakeholders' perspectives to guide organizations in this transition. Moreover, developing countries face specific challenges that require prioritizing the proper set of CSFs for sustainable digitalization. Therefore, this paper aims to develop a CSFs-based taxonomy for S-OSCM4.0 to help organizations stay current in I4.0 adoption and integrate sustainability in OSCM. We first conducted a systematic literature review (SLR) of 131 papers using bibliometric and content analyses and synthesized the theoretical findings into an alpha taxonomy of CSFs following an inductive approach. Then, we employed a Delphi survey technique combining fuzzy logic to solicit experts' perceptions from a developing country to analyze and validate the taxonomy and determine the most pertinent CSFs, resulting in a beta taxonomy of CSFs for S-OSCM4.0. The developed taxonomy represents a pioneering managerial artefact that can guide sustainable development through an inclusive digital transformation with less environmental impact, contributing to decision-making in S-OSCM4.0, especially for operations in developing countries

    Dynamic heterogeneities in the out-of-equilibrium dynamics of simple spherical spin models

    Full text link
    The response of spherical two-spin interaction models, the spherical ferromagnet (s-FM) and the spherical Sherrington-Kirkpatrick (s-SK) model, is calculated for the protocol of the so-called nonresonant hole burning experiment (NHB) for temperatures below the respective critical temperatures. It is shown that it is possible to select dynamic features in the out-of-equilibrium dynamics of both models, one of the hallmarks of dynamic heterogeneities. The behavior of the s-SK model and the s-FM in three dimensions is very similar, showing dynamic heterogeneities in the long time behavior, i.e. in the aging regime. The appearence of dynamic heterogeneities in the s-SK model explicitly demonstrates that these are not necessarily related to {\it spatial} heterogeneities. For the s-FM it is shown that the nature of the dynamic heterogeneities changes as a function of dimensionality. With incresing dimension the frequency selectivity of the NHB diminishes and the dynamics in the mean-field limit of the s-FM model becomes homogeneous.Comment: 16 pages, 8 figure

    Entanglement, quantum phase transition and scaling in XXZ chain

    Full text link
    Motivated by recent development in quantum entanglement, we study relations among concurrence CC, SUq_q(2) algebra, quantum phase transition and correlation length at the zero temperature for the XXZ chain. We find that at the SU(2) point, the ground state possess the maximum concurrence. When the anisotropic parameter Δ\Delta is deformed, however, its value decreases. Its dependence on Δ\Delta scales as C=C0C1(Δ1)2C=C_0-C_1(\Delta-1)^2 in the XY metallic phase and near the critical point (i.e. 1<Δ<1.31<\Delta<1.3) of the Ising-like insulating phase. We also study the dependence of CC on the correlation length ξ\xi, and show that it satisfies C=C01/2ξC=C_0-1/2\xi near the critical point. For different size of the system, we show that there exists a universal scaling function of CC with respect to the correlation length ξ\xi.Comment: 4 pages, 3 figures. to appear in Phys. Rev.

    Identifying and managing patient–ventilator asynchrony: An international survey.

    Get PDF
    Objective: To describe the main factors associated with proper recognition and management of patient ventilator asynchronies (PVA). Design: Analytical cross-sectional study. Setting: International study conducted in 20 countries through an online survey. Participants: Physicians, respiratory therapists, nurses and physiotherapists that are currently working at the Intensive Care Unit (ICU). Main variables of interest: Univariate and multivariate logistic regression models were used to establish associations between all variables (profession, training in mechanical ventilation, type of training program, years of experience and ICU characteristics) with the ability of HCPs to correctly identify and manage 6 PVA. Results: A total of 431 HCPs answered a validated survey. The main factors associated with the proper recognition of PVA were: specific training program in mechanical ventilation (MV) (OR 2.27; 95% CI 1.14-4.52; p = 0.019), courses with more than 100 hours completed (OR 2.28; 95% CI 1.29-4.03; p = 0.005) and the number of intensive care unit (ICU) beds (OR 1.037; 95% CI 1.01-1.06; p = 0.005). The main factor that influenced PVA management was recognizing 6 PVA correctly (OR 118.98; 95%CI 35.25-401.58; p < 0.001). Conclusion: Identifying and managing PVA using ventilator waveform analysis is influenced by many factors including specific training programs in MV, number of ICU beds and the recognized number of PVA.pre-print169 K

    Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Full text link
    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114.Moliner Martínez, L.; Correcher, C.; González Martínez, AJ.; Conde Castellanos, PE.; Hernández Hernández, L.; Orero Palomares, A.; Rodríguez Álvarez, MJ.... (2013). Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:129-132. https://doi.org/10.1016/j.nima.2012.08.029S12913270

    NMR signal enhancement of > 50 000 times in fast dissolution dynamic nuclear polarization

    Get PDF
    Herein, we report the synthesis and the study of a novel mixed biradical with BDPA and TEMPO radical units that are covalently bound by an ester group (BDPAesterTEMPO) as a polarizing agent for fast dissolution DNP. The biradical exhibits an extremely high DNP NMR enhancement of >50 000 times, which constitutes one of the largest signal enhancements observed so far, to the best of our knowledg

    Monolithic crystals for PET devices: optical coupling optimization

    Full text link
    NOTICE: this is the author’s version of a work that was accepted for publication in Nuclear Instruments and Methods in Physics Research Section A. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A [Volume 731, 11 December 2013, Pages 288–294] DOI 10.1016/j.nima.2013.05.049[EN] In this work we present a method to efficiently collect scintillation light when using monolithic scintillator crystals. The acceptance angle of the scintillation light has been reduced by means of optical devices reducing the border effect which typically affects continuous crystals. We have applied this procedure on gamma detectors for PET systems using both position sensitive PMTs and arrays of SiPMs. In the case of using SiPMs, this approach also helps to reduce the photosensor active area. We evaluated the method using PMTs with a variety of different crystals with thicknesses ranging from 10 to 24 mm. We found that our design allows the use of crystal blocks with a thickness of up to 18 mm without degrading the spatial resolution caused by edge effects and without a significant detriment to the energy resolution. These results were compared with simulated data. The first results of monolithic LYSO crystals coupled to an array of 256 SiPMs by means of individual optical light guides are also presented.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D +I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.González Martínez, AJ.; Peiró, A.; Conde, P.; Hernández Hernández, L.; Moliner Martínez, L.; Orero Palomares, A.; Rodríguez-Álvarez, M.... (2013). Monolithic crystals for PET devices: optical coupling optimization. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 731:288-294. https://doi.org/10.1016/j.nima.2013.05.049S28829473

    Design of the PET–MR system for head imaging of the DREAM Project

    Full text link
    NOTICE: this is the author’s version of a work that was accepted for publication in Nuclear Instruments and Methods in Physics Research Section A. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Nuclear Instruments and Methods in Physics Research Section A, Volume 702, 21 February 2013, Pages 94–97 DOI 10.1016/j.nima.2012.08.028In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems.This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I + D + I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.González Martínez, AJ.; Conde, P.; Hernández Hernández, L.; Herrero Bosch, V.; Moliner Martínez, L.; Monzó Ferrer, JM.; Orero Palomares, A.... (2013). Design of the PET–MR system for head imaging of the DREAM Project. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 702:94-97. https://doi.org/10.1016/j.nima.2012.08.028S949770

    Expectation maximization (EM) algorithms using polar symmetriesfor computed tomography(CT) image reconstruction

    Full text link
    We suggest a symmetric-polar pixellation scheme which makes possible a reduction of the computational cost for expectation maximization (EM) iterative algorithms. The proposed symmetric-polar pixellation allows us to deal with 3D images as a whole problem without dividing the 3D problem into 2D slices approach. Performance evaluation of each approach in terms of stability and image quality is presented. Exhaustive comparisons between all approaches were conducted in a 2D based image reconstruction model. From these 2D approaches, that showing the best performances were finally implemented and evaluated in a 3D based image reconstruction model. Comparison to 3D images reconstructed with FBP is also presented. Although the algorithm is presented in the context of computed tomography (CT) image reconstruction, it can be applied to any other tomographic technique as well, due to the fact that the only requirement is a scanning geometry involving measurements of an object under different projection angles. Real data have been acquired with a small animal (CT) scanner to verify the proposed mathematical description of the CT system.This work was supported by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant, FIS2010-21216-CO2-01, Valencian Local Government under Grant Nos. PROMETEO 2008/114 and APOSTD/2010/012. The authors would like to thank Brennan Holt for checking and correcting the text.Rodríguez Álvarez, MJ.; Soriano Asensi, A.; Iborra Carreres, A.; Sánchez Martínez, F.; González Martínez, AJ.; Conde, P.; Hernández Hernández, L.... (2013). Expectation maximization (EM) algorithms using polar symmetriesfor computed tomography(CT) image reconstruction. Computers in Biology and Medicine. 43(8):1053-1061. https://doi.org/10.1016/j.compbiomed.2013.04.015S1053106143
    corecore