57 research outputs found

    Two cases of fungal keratitis caused by Metarhizium anisopliae

    Get PDF
    We present two cases of keratitis due to Metarhizium anisopliae in geographically separated areas of the United States. The isolates were microscopically similar but morphologically different and were identified by ribosomal DNA sequencing. Both isolates had low minimum inhibitory concentration (MIC) values to caspofungin and micafungin, but high MIC values to amphotericin B. The morphologic and antifungal susceptibility differences between the two isolates indicate possible polyphylogeny of the group. Keywords: Metarhizium, Fungal keratitis, Keratomycosis, Antifungal susceptibilit

    Changes in SARS-CoV-2 viral load and mortality during the initial wave of the pandemic in New York City

    Get PDF
    Funding: This work was partially supported by the National Center for Advancing Translational Sciences of the National Institutes of Health (UL1 TR0023484 to Julianne Imperato-McGinley) and the National Institute of Allergy and Infectious Diseases (UM1 AI069470 to M.E.S).Public health interventions such as social distancing and mask wearing decrease the incidence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, but it is unclear whether they decrease the viral load of infected patients and whether changes in viral load impact mortality from coronavirus disease 2019 (COVID-19). We evaluated 6923 patients with COVID-19 at six New York City hospitals from March 15-May 14, 2020, corresponding with the implementation of public health interventions in March. We assessed changes in cycle threshold (CT) values from reverse transcription-polymerase chain reaction tests and in-hospital mortality and modeled the impact of viral load on mortality. Mean CT values increased between March and May, with the proportion of patients with high viral load decreasing from 47.7% to 7.8%. In-hospital mortality increased from 14.9% in March to 28.4% in early April, and then decreased to 8.7% by May. Patients with high viral loads had increased mortality compared to those with low viral loads (adjusted odds ratio 2.34). If viral load had not declined, an estimated 69 additional deaths would have occurred (5.8% higher mortality). SARS-CoV-2 viral load steadily declined among hospitalized patients in the setting of public health interventions, and this correlated with decreases in mortality.Peer reviewe

    The conserved C-terminus of the PcrA/UvrD helicase interacts directly with RNA polymerase

    Get PDF
    Copyright: © 2013 Gwynn et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Funding: This work was supported by a Wellcome Trust project grant to MD (Reference: 077368), an ERC starting grant to MD (Acronym: SM-DNA-REPAIR) and a BBSRC project grant to PM, NS and MD (Reference: BB/I003142/1). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.Peer reviewedPublisher PD

    Evaluation of Oxacillin and Cefoxitin Disk and MIC Breakpoints for Prediction of Methicillin Resistance in Human and Veterinary Isolates of Staphylococcus intermedius Group

    Get PDF
    Staphylococcus pseudintermedius is a coagulase-positive species that colonizes the nares and anal mucosa of healthy dogs and cats. Human infections with S. pseudintermedius range in severity from bite wounds and rhinosinusitis to endocarditis; historically, these infections were thought to be uncommon, but new laboratory methods suggest that their true incidence is underreported. Oxacillin and cefoxitin disk and MIC tests were evaluated for the detection of mecA- or mecC-mediated methicillin resistance in 115 human and animal isolates of the Staphylococcus intermedius group (SIG), including 111 Staphylococcus pseudintermediusand 4 Staphylococcus delphini isolates, 37 of which were mecA positive. The disk and MIC breakpoints evaluated included the Clinical and Laboratory Standards Institute (CLSI) M100-S25 Staphylococcus aureus/Staphylococcus lugdunensis oxacillin MIC breakpoints and cefoxitin disk and MIC breakpoints, the CLSI M100-S25 coagulase-negative Staphylococcus (CoNS) oxacillin MIC breakpoint and cefoxitin disk breakpoint, the CLSI VET01-S2 S. pseudintermedius oxacillin MIC and disk breakpoints, and the European Committee on Antimicrobial Susceptibility Testing (EUCAST) S. pseudintermedius cefoxitin disk breakpoint. The oxacillin results interpreted by the VET01-S2 (disk and MIC) and M100-S25 CoNS (MIC) breakpoints agreed with the results of mecA/mecC PCR for all isolates, with the exception of one false-resistant result (1.3% of mecA/mecC PCR-negative isolates). In contrast, cefoxitin tests performed poorly, ranging from 3 to 89% false susceptibility (very major errors) and 0 to 48% false resistance (major errors). BD Phoenix, bioMérieux Vitek 2, and Beckman Coulter MicroScan commercial automated susceptibility test panel oxacillin MIC results were also evaluated and demonstrated >95% categorical agreement with mecA/mecC PCR results if interpreted by using the M100-S25 CoNS breakpoint. The Alere penicillin-binding protein 2a test accurately detected all mecA-positive isolates, although for four isolates, cefoxitin induction was required prior to testing. These data demonstrate that the cefoxitin surrogate test does not reliably detect the presence of mecA in S. pseudintermedius isolates and that laboratories should perform oxacillin disk or MIC tests of these isolates when they are encountered

    Multicenter evaluation of the vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of gram-positive aerobic bacteria

    Get PDF
    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 system (bioMérieux, Inc.) for the identification of aerobic Gram-positive bacteria. A total of 1,146 unique isolates, representing 13 genera and 42 species, were analyzed, and results were compared to those obtained by nucleic acid sequence-based identification as the reference method. For 1,063 of 1,146 isolates (92.8%), the Vitek MS provided a single identification that was accurate to the species level. For an additional 31 isolates (2.7%), multiple possible identifications were provided, all correct at the genus level. Mixed-genus or single-choice incorrect identifications were provided for 18 isolates (1.6%). Although no identification was obtained for 33 isolates (2.9%), there was no specific bacterial species for which the Vitek MS consistently failed to provide identification. In a subset of 463 isolates representing commonly encountered important pathogens, 95% were accurately identified to the species level and there were no misidentifications. Also, in all but one instance, the Vitek MS correctly differentiated Streptococcus pneumoniae from other viridans group streptococci. The findings demonstrate that the Vitek MS system is highly accurate for the identification of Gram-positive aerobic bacteria in the clinical laboratory setting

    Evaluation of an Immunochromatographic Assay for Rapid Detection of Penicillin-Binding Protein 2a in Human and Animal Staphylococcus intermedius Group, Staphylococcus lugdunensis, and Staphylococcus schleiferi Clinical Isolates

    Get PDF
    The performance of a rapid penicillin-binding protein 2a (PBP2a) detection assay, the Alere PBP2a culture colony test, was evaluated for identification of PBP2a-mediated beta-lactam resistance in human and animal clinical isolates of Staphylococcus intermedius group, Staphylococcus lugdunensis, and Staphylococcus schleiferi. The assay was sensitive and specific, with all PBP2a-negative and PBP2a-positive strains testing negative and positive, respectively
    corecore