870 research outputs found

    On the measurement uncertainty of microdosimetric quantities using diamond and silicon microdosimeters in carbon-ion beams

    Get PDF
    Purpose: The purpose of this paper is to compare the response of two different types of solid-state microdosimeters, that is, silicon and diamond, and their uncertainties. A study of the conversion of silicon microdosimetric spectra to the diamond equivalent for microdosimeters with different geometry of the sensitive volumes is performed, including the use of different stopping power databases. Method: Diamond and silicon microdosimeters were irradiated under the same conditions, aligned at the same depth in a carbon-ion beam at the MedAustron ion therapy center. In order to estimate the microdosimetric quantities, the readout electronic linearity was investigated with three different methods, that is, the first being a single linear regression, the second consisting of a double linear regression with a channel transition and last a multiple linear regression by splitting the data into odd and even groups. The uncertainty related to each of these methods was estimated as well. The edge calibration was performed using the intercept with the horizontal axis of the tangent through the inflection point of the Fermi function approximation multi-channel analyzer spectrum. It was assumed that this point corresponds to the maximum energy difference of particle traversing the sensitive volume (SV) for which the residual range difference in the continuous slowing down approximation is equal to the thickness of the SV of the microdosimeter. Four material conversion methods were explored, the edge method, the density method, the maximum-deposition energy method and the bin-by-bin transformation method. The uncertainties of the microdosimetric quantities resulting from the linearization, the edge calibration and the detectors thickness were also estimated. Results: It was found that the double linear regression had the lowest uncertainty for both microdosimeters. The propagated standard (k = 1) uncertainties on the frequency-mean lineal energy y¯FyˉF{\bar{y}}_{\rm{F}} and the dose-mean lineal energy y¯DyˉD{\bar{y}}_{\rm{D}} values from the marker point, in the spectra, in the plateau were 0.1% and 0.2%, respectively, for the diamond microdosimeter, whilst for the silicon microdosimeter data converted to diamond, the uncertainty was estimated to be 0.1%. In the range corresponding to the 90% of the amplitude of the Bragg Peak at the distal part of the Bragg curve (R90 ) the uncertainty was found to be 0.1%. The uncertainty propagation from the stopping power tables was estimated to be between 5% and 7% depending on the method. The uncertainty on the y¯FyˉF{\bar{y}}_{\rm{F}} and y¯DyˉD{\bar{y}}_{\rm{D}} coming from the thickness of the detectors varied between 0.3% and 0.5%. Conclusion: This article demonstrate that the linearity of the readout electronics affects the microdosimetric spectra with a difference in y¯FyˉF{\bar{y}}_{\rm{F}} values between the different linearization methods of up to 17.5%. The combined uncertainty was dominated by the uncertainty of stopping power on the edge

    Concentration- and time-dependent effectof aminooxyacetic acidon cortical epileptogenicity

    Get PDF
    In the present electrophysiological study the effect of aminooxyacetic acid (AOAA) on the cortical epileptogenicity, and on the basic electro-cortical activity was investigated in anesthetized rats.AOAA did not induce spontaneous epileptiform discharges but modified the somato-sensory evoked responses and the cortical epileptogenicity (induced by 4-aminopyridine) in the same manner depending on its concentration. AOAA at low concentrations increased the amplitude of evoked responses and the ipsilateral manifestation of epileptiform activity, however, at high concentrations significantly suppressed both the evoked responses and the induction and expression of seizures discharges. The anticonvulsive effect of AOAA was time-dependent (reached its maximum after 2h AOAA pre-treatment) and reversible. AOAA at low concentrations probably increases the efficacy of the NMDA excitatory system and decreases GABA-synthesis, resulting neuronal hyperexcitation. However, AOAA at high concentrations can lead to an effective cortical inhibition through intra- and extracellular accumulation of GABA. The gradual GABA accumulation - up to a certain level - at the synapses could also explain the time-dependency of the anticonvulsive effect of AOAA

    Resonant third harmonic generation of KrF laser in Ar gas

    Get PDF
    Investigations of emission of harmonics from argon gas jet irradiated by 700 fs, 5 mJ pulses from a KrF laser are presented. Harmonics conversion was optimized by varying the experimental geometry and the nozzle size. For the collection of the harmonic radiation silicon and solar-blind diamond semiconductor detectors equipped with charge preamplifiers were applied. The possibility of using a single-crystal CVD diamond detector for separate measurement of the 3rd harmonic in the presence of a strong pumping radiation was explored. Our experiments show that the earlier suggested 0.7% conversion efficiency can really be obtained, but only in the case when phase matching is optimized with an elongated gas target length corresponding to the length of coherence

    Analytic traveling-wave solutions of the Kardar-Parisi-Zhang interface growing equation with different kind of noise terms

    Full text link
    The one-dimensional Kardar-Parisi-Zhang dynamic interface growth equation with the traveling-wave Ansatz is analyzed. As a new feature additional analytic terms are added. From the mathematical point of view, these can be considered as various noise distribution functions. Six different cases were investigated among others Gaussian, Lorentzian, white or even pink noise. Analytic solutions are evaluated and analyzed for all cases. All results are expressible with various special functions Mathieu, Bessel, Airy or Whittaker functions showing a very rich mathematical structure with some common general characteristics. This study is the continuation of our former work, where the same physical phenomena was investigated with the self-similar Ansatz. The differences and similarities among the various solutions are enlightened.Comment: 14 pages,14 figures. arXiv admin note: text overlap with arXiv:1904.0183

    Energy dependence of kaon-to-proton ratio fluctuations in central Pb+Pb collisions from sNN\sqrt{s_{NN}} = 6.3 to 17.3 GeV

    Get PDF
    Kaons and protons carry large parts of two conserved quantities, strangeness and baryon number. It is argued that their correlation and thus also fluctuations are sensitive to conditions prevailing at the anticipated parton-hadron phase boundary. Fluctuations of the (K++K)/(p+pˉ)(\mathrm{K}^+ + \mathrm{K}^-)/(\mathrm{p}+\bar{\mathrm{p}}) and K+/p\mathrm{K}^+/\mathrm{p} ratios have been measured for the first time by NA49 in central Pb+Pb collisions at 5 SPS energies between sNN\sqrt{s_{NN}}= 6.3 GeV and 17.3 GeV. Both ratios exhibit a change of sign in σdyn\sigma_{\mathrm{dyn}}, a measure of non-statistical fluctuations, around sNN\sqrt{s_{NN}} = 8 GeV. Below this energy, σdyn\sigma_{\mathrm{dyn}} is positive, indicating higher fluctuation compared to a mixed event background sample, while for higher energies, σdyn\sigma_{\mathrm{dyn}} is negative, indicating correlated emission of kaons and protons. The results are compared to UrQMD calculations which which give a good description at the higher SPS energies, but fail to reproduce the transition to positive values.Comment: 5 pages, 4 figure

    System-size and centrality dependence of charged kaon and pion production in nucleus-nucleus collisions at 40A GeV and158A GeV beam energy

    Get PDF
    Measurements of charged pion and kaon production are presented in centrality selected Pb+Pb collisions at 40A GeV and 158A GeV beam energy as well as in semi-central C+C and Si+Si interactions at 40A GeV. Transverse mass spectra, rapidity spectra and total yields are determined as a function of centrality. The system-size and centrality dependence of relative strangeness production in nucleus-nucleus collisions at 40A GeV and 158A GeV beam energy are derived from the data presented here and published data for C+C and Si+Si collisions at 158A GeV beam energy. At both energies a steep increase with centrality is observed for small systems followed by a weak rise or even saturation for higher centralities. This behavior is compared to calculations using transport models (UrQMD and HSD), a percolation model and the core-corona approach.Comment: 32 pages, 14 figures, 4 tables, typo table II correcte
    corecore