    Piezoelectric composite materials

    Get PDF
    A laminated structural devices has the ability to change shape, position and resonant frequency without using discrete motive components. The laminate may be a combination of layers of a piezoelectrically active, nonconductive matrix material. A power source selectively places various levels of charge in electrically conductive filaments imbedded in the respective layers to produce various configurations in a predetermined manner. The layers may be electrically conductive having imbedded piezoelectrically active filaments. A combination of layers of electrically conductive material may be laminated to layers of piezoelectrically active material

    A high speed implementation of the random decrement algorithm

    Get PDF
    The algorithm is useful for measuring net system damping levels in stochastic processes and for the development of equivalent linearized system response models. The algorithm works by summing together all subrecords which occur after predefined threshold level is crossed. The random decrement signature is normally developed by scanning stored data and adding subrecords together. The high speed implementation of the random decrement algorithm exploits the digital character of sampled data and uses fixed record lengths of 2(n) samples to greatly speed up the process. The contributions to the random decrement signature of each data point was calculated only once and in the same sequence as the data were taken. A hardware implementation of the algorithm using random logic is diagrammed and the process is shown to be limited only by the record size and the threshold crossing frequency of the sampled data. With a hardware cycle time of 200 ns and 1024 point signature, a threshold crossing frequency of 5000 Hertz can be processed and a stably averaged signature presented in real time

    Digital system for dynamic turbine engine blade displacement measurements

    Get PDF
    An instrumentation concept for measuring blade tip displacements which employs optical probes and an array of micro-computers is presented. The system represents a hitherto unknown instrumentation capability for the acquisition and direct digitization of deflection data concurrently from all of the blade tips of an operational engine rotor undergoing flutter or forced vibration. System measurements are made using optical transducers which are fixed to the case. Measurements made in this way are the equivalent of those obtained by placing three surface-normal displacement transducers at three positions on each blade of an operational rotor

    Asymmetric fundamental band CO lines as a sign of an embedded giant planet

    Get PDF
    We investigate the formation of double-peaked asymmetric line profiles of CO in the fundamental band spectra emitted by young (1-5Myr) protoplanetary disks hosted by a 0.5-2 Solar mass star. Distortions of the line profiles can be caused by the gravitational perturbation of an embedded giant planet with q=4.7 10^-3 stellar-to-planet mass ratio. Locally isothermal, 2D hydrodynamic simulations show that the disk becomes globally eccentric inside the planetary orbit with stationary ~0.2-0.25 average eccentricity after ~2000 orbital periods. For orbital distances 1-10 AU, the disk eccentricity is peaked inside the region where the fundamental band of CO is thermal excitated. Hence, these lines become a sensitive indicators of the embedded planet via their asymmetries (both in flux and wavelength). We find that the line shape distortions (e.g. distance, central dip, asymmetry and positions of peaks) of a given transition depend on the excitation energy (i.e. on the rotational quantum number J). The magnitude of line asymmetry is increasing/decreasing with J if the planet orbits inside/outside the CO excitation zone (R_CO<=3, 5 and 7 AU for a 0.5,1 and 2 Solar mass star, respectively), thus one can constrain the orbital distance of a giant planet by determining the slope of peak asymmetry-J profile. We conclude that the presented spectroscopic phenomenon can be used to test the predictions of planet formation theories by pushing the age limits for detecting the youngest planetary systems.Comment: 7 pages, 5 figures, to appear in ApJ

    Rim-spoke composite flywheels: Stress and vibration analysis

    Get PDF
    Elementary relations are described to determine the material utilization efficiency of a thin wall rim composite flywheel over other configurations. An algorithm is generated for the automatic selection of the optimum composite material for a given thin rim flywheel environment. Subsequently, the computer program NASTRAN is used to perform a detailed stress and vibration analysis of thin wall cylindrical shell rim spoke, single rim and multirim composite flywheels for a specific application

    Ultrasonic scanning system for imaging flaw growth in composites

    Get PDF
    A system for measuring and visually representing damage in composite specimens while they are being loaded was demonstrated. It uses a hobbiest grade microcomputer system to control data taking and image processing. The system scans operator selected regions of the specimen while it is under load in a tensile test machine and measures internal damage by the attenuation of a 2.5 MHz ultrasonic beam passed through the specimen. The microcomputer dynamically controls the position of ultrasonic transducers mounted on a two axis motor driven carriage. As many as 65,536 samples can be taken and filed on a floppy disk system in less than four minutes

    Involvement of Nitric Oxide in Microcirculatory Reactions after Ischemia-Reperfusion of the Rat Urinary Bladder

    Get PDF
    Background: Nitric oxide ( NO) plays a role in inflammation. Our aim was to investigate the role of NO in the microcirculatory changes after ischemia-reperfusion (I/R) of the bladder using intravital videomicroscopy (IVM). Methods: In rats, 60 min of bladder ischemia followed by 30 min of reperfusion was performed in the presence of N(G)-nitro-L-arginine methyl ester (L-NAME), the NO precursor L-arginine, or saline pre-treatments. Venular red blood cell velocity (RBCV), functional capillary density (FCD), vessel diameters, and leukocyte-endothelial cell interactions in postcapillary venules were determined. Concentrations of nitrite/nitrate in the plasma and myeloperoxidase (MPO) levels in the lungs and the bladder were measured. Results: Elevations of the numbers of rolling and adherent leukocytes, and of plasma nitrite/nitrate levels were found, while FCD and RBCV decreased. L-NAME pretreatment ameliorated the enhanced leukocyte-endothelial cell interactions without influencing the microcirculatory perfusion. In contrast, the L - arginine pretreatment further increased plasma nitrite/nitrate levels and preserved the FCD and RBCV, but did not affect leukocyte-endothelial interactions. None of these treatments influenced MPO activities. Conclusion: Our results suggest that NO plays an enhancing role in the I/R-induced neutrophil-endothelial interactions of the bladder. Supplementation of NO ameliorates the microcirculatory perfusion deficit without influencing the postischemic microcirculatory inflammatory reactions. Copyright (c) 2008 S. Karger AG, Base

    Computational structural methods at NASA Lewis

    Get PDF
    Viewgraphs on computational structural methods at the Lewis Research Center are given. Program objectives, work elements, resources, parallel-processing, FY-87 accomplishments, FY-88 plans, and a summary of current and planned activities are illustrated

    Structural dynamic measurement practices for turbomachinery at the NASA Lewis Research Center

    Get PDF
    Methods developed for measuring blade and rotor-shaft system response include optical systems, transient instruments, and special digital data processing equipment. Optical methods offer some distinct benefits for blade vibration measurement. Transient and steady state measurements of the response of rotor-shaft systems strongly affect analytical methods development. Digital computing systems allow processing of large volumes of high speed data from rotating blade sets. Also, digital systems develop useful vibration response signatures from randomly excited systems. Research facilities include the spin rig facility and the transient rotor response lab

    Algebraic-Combinatorial Methods for Low-Rank Matrix Completion with Application to Athletic Performance Prediction

    Get PDF
    This paper presents novel algorithms which exploit the intrinsic algebraic and combinatorial structure of the matrix completion task for estimating missing en- tries in the general low rank setting. For positive data, we achieve results out- performing the state of the art nuclear norm, both in accuracy and computational efficiency, in simulations and in the task of predicting athletic performance from partially observed data
    • …