    Quantifying material loss from the bearing surfaces of retrieved hip replacements: Method validation

    Get PDF
    Computational methods used to quantify wear in failed hip arthroplasties are often limited by human and sampling errors. An automated software solution has been developed to overcome these shortcomings. The overarching aim of the current study was to validate this method through a comparison with gravimetric measurements. Seventy-two different wear volumes were quantified to within a mean error of 0.14 mm3 and 0.10 mm3 of gravimetric results for simulated cup and head components, respectively. This approach had an improved accuracy, repeatability and reproducibility over a commonly used, commercially available software solution, which bears many of the common sources of error

    Comparative analysis of current 3D printed acetabular titanium implants

    Get PDF
    BACKGROUND: The design freedom allowed by three-dimensional (3D) printing enables the production of acetabular off-the-shelf cups with complex porous structures. The only studies on these designs are limited to clinical outcomes. Our aim was to analyse and compare the designs of different 3D printed cups from multiple manufacturers (Delta TT, Trident II Tritanium and Mpact 3D Metal). METHODS: We analysed the outer surface of the cups using scanning electron microscopy (SEM) and assessed clinically relevant morphometric features of the lattice structures using micro-computed tomography (micro-CT). Dimensions related to the cup wall (solid, lattice and overall thickness) were also measured. Roundness and roughness of the internal cup surface were analysed with coordinate measuring machine (CMM) and optical profilometry. RESULTS: SEM showed partially molten titanium beads on all cups, significantly smaller on Trident II (27 μm vs ~ 70 μm, p < 0.0001). We found a spread of pore sizes, with median values of 0.521, 0.841 and 1.004 mm for Trident II, Delta TT and Mpact, respectively. Trident II was also significantly less porous (63%, p < 0.0001) than the others (Delta TT 72.3%, Mpact 76.4%), and showed the thinnest lattice region of the cup wall (1.038 mm, p < 0.0001), while Mpact exhibited the thicker solid region (4.880 mm, p < 0.0044). Similar roundness and roughness of the internal cup surfaces were found. CONCLUSION: This was the first study to compare the designs of different 3D printed cups. A variability in the morphology of the outer surface of the cups and lattice structures was found. The existence of titanium beads on 3D printed parts is a known by-product of the manufacturing process; however, their prevalence on acetabular cups used in patients is an interesting finding, since these beads may potentially be released in the body

    Analysis of bearing wear, whole blood and synovial fluid metal ion concentrations and histopathological findings in patients with failed ASR hip resurfacings

    Get PDF
    Background Adverse Reaction to Metal Debris (ARMD) is still a major reason for revision surgeries in patients with metal-on-metal (MoM) hip replacements. ARMD consists of a wide range of alterations in periprosthetic tissues, most important of which are metallosis, inflammation, pseudotumors and necrosis. Studies investigating histopathological findings and their association to implant wear or indirect measures of wear have yielded inconsistent results. Therefore, we aimed to investigate bearing surface wear volume, whole blood and synovial fluid metal ion concentrations, histopathological findings in periprosthetic tissues and their associations. Methods Seventy-eight patients with 85 hips revised for ARMD were included in the study. Prior to revision surgery, all patients had whole blood chromium and cobalt ion levels assessed. In revision surgery, a synovial fluid sample was taken and analyzed for chromium and cobalt. Periprosthetic tissue samples were taken and analyzed for histopathological findings. Explanted implants were analyzed for bearing wear volume of both acetabular cup and femoral head components. Results Volumetric wear of the failed components was highly variable. The total wear volume of the head and cup had a strong correlation with whole blood chromium and cobalt ion concentrations (Cr: ρ = 0.80, p < 0.001 and Co: ρ = 0.84, p < 0.001) and a bit weaker correlation with fluid chromium and cobalt ion concentrations (Cr: ρ = 0.50, p < 0.01 and Co: ρ = 0.41, p = 0.027). Most tissues displayed only low-to-moderate amounts of macrophages and lymphocytes. Total wear volume correlated with macrophage sheet thickness (ρ = 0.25, p = 0.020) and necrosis (ρ = 0.35, p < 0.01). Whole blood chromium and cobalt ion concentrations had similar correlations. Lymphocyte cuff thickness did not correlate with either total wear volume or whole blood metal ion concentrations, but correlated with the grade of necrosis. Conclusions Bearing wear volume correlated with blood metal ion levels and the degree of necrosis and macrophage infiltration in periprosthetic tissues suggesting a dose-response relationship. Whole blood metal ion levels are a useful tool for clinician to estimate bearing wear and subsequent tissue response

    Magnetic Resonance Imaging of the Hips of Runners Before and After Their First Marathon Run: Effect of Training for and Completing a Marathon

    Get PDF
    Background: No studies have focused on magnetic resonance imaging (MRI) of the hips of marathoners, despite the popularity and injury risks of marathon running. / Purpose: To understand the effect of preparing for and completing a marathon run (42 km) on runners’ hip joints by comparing MRI findings before and after their first marathon. / Study Design: Case-control study; Level of evidence, 3. / Methods: A total of 28 healthy adults (14 males, 14 females; mean age, 32.4 years) were recruited after registering for their first marathon. They underwent 3-T MRI of both hips at 16 weeks before (time point 1) and 2 weeks after the marathon (time point 2). After the first MRI, 21 runners completed the standardized, 4 month--long training program and the marathon; 7 runners did not complete the training or the marathon. Specialist musculoskeletal radiologists reported and graded the hip joint structures using validated scoring systems. Participants completed the Hip disability and Osteoarthritis Outcome Score (HOOS) at both imaging time points. / Results: At time point 1, MRI abnormalities of the hip joint were seen in 90% of participants and were located in at least 1 of these areas: labrum (29%), articular cartilage (7%), subchondral bone marrow (14%), tendons (17%), ligaments (14%), and muscles (31% had moderate muscle atrophy). At time point 2, only 2 of the 42 hips showed new findings: a small area of mild bone marrow edema appearance (nonweightbearing area of the hip and not attributable to running). There was no significant difference in HOOS between the 2 time points. Only 1 participant did not finish the training because of hip symptoms and thus did not run the marathon; however, symptoms resolved before the MRI at time point 2. Six other participants discontinued their training because of non–hip related issues: a knee injury, skin disease, a family bereavement, Achilles tendon injury, illness unrelated to training, and a foot injury unrelated to training. / Conclusion: Runners who completed a 4-month beginner training program before their first marathon run, plus the race itself, showed no hip damage on 3-T MRI scans

    Evidence of structural cavities in 3D printed acetabular cups for total hip arthroplasty

    Get PDF
    The use of three‐dimensional (3D) printing to manufacture off‐the‐shelf titanium acetabular cups for hip arthroplasty has increased; however, the impact of this manufacturing technology is yet not fully understood. Although several studies have described the presence of structural cavities in 3D printed parts, there has been no analysis of full postproduction acetabular components. The aim of this study was to investigate the effect of 3D printing on the material structure of acetabular implants, first comparing different designs of 3D printed cups, second comparing 3D printed with conventionally manufactured cups. Two of the 3D printed cups were produced using electron beam melting (EBM), one using laser rapid manufacturing (LRM). The investigation was performed using X‐ray microcomputed tomography, imaging both the entire cups and samples sectioned from different regions of each cup. All 3D printed cups showed evidence of structural cavities; these were uniformly distributed in the volume of the samples and exhibited a prevalent spherical shape. The LRM‐manufactured cup had significantly higher cavity density (p = .0286), with a median of 21 cavities/mm^{3} compared to 3.5 cavities/mm^{3} for EBM cups. However, the cavity size was similar, with a median of 20 μm (p = .7385). The conventional cups showed a complete absence of distinguishable cavities. The presence of cavities is a known limitation of the 3D printing technology; however, it is noteworthy that we found them in orthopedic implants used in patients. Although this may impact their mechanical properties, to date, 3D printed cups have not been reported to encounter such failures

    Dimensional analysis of 3D-printed acetabular cups for hip arthroplasty using X-ray microcomputed tomography

    Get PDF
    Purpose Three-dimensional (3D) printing is increasingly used to produce orthopaedic components for hip arthroplasty, such as acetabular cups, which show complex lattice porous structures and shapes. However, limitations on the quality of the final implants are present; thus, investigations are needed to ensure adequate quality and patients safety. X-ray microcomputed tomography (micro-CT) has been recognised to be the most suitable method to evaluate the complexity of 3D-printed parts. The purpose of this study was to assess the reliability of a micro-CT analysis method comparing it with reference systems, such as coordinate measuring machine and electron microscopy. Design/methodology/approach 3D-printed acetabular components for hip arthroplasty (n = 2) were investigated. Dimensions related to the dense and porous regions of the samples were measured. The micro-CT scanning parameters (voltage – kV, current – µA) were optimised selecting six combinations of beam voltage and current. Findings Micro-CT showed good correlation and agreement with both coordinate measuring machine and scanning electron microscopy when optimal scanning parameters were selected (130 kV – 100 µA to 180 kV – 80 µA). Mean discrepancies of 50 µm (± 300) and 20 µm (± 60) were found between the techniques for dense and porous dimensions. Investigation method such as micro-CT imaging may help to better understand the impact of 3D printing manufacturing technology on the properties of orthopaedic implants. Originality/value The optimisation of the scanning parameters and the validation of this method with reference techniques may guide further analysis of similar orthopaedic components

    Night Matters—Why the Interdisciplinary Field of “Night Studies” Is Needed

    Get PDF
    The night has historically been neglected in both disciplinary and interdisciplinary research. To some extent, this is not surprising, given the diurnal bias of human researchers and the difficulty of performing work at night. The night is, however, a critical element of biological, chemical, physical, and social systems on Earth. Moreover, research into social issues such as inequality, demographic changes, and the transition to a sustainable economy will be compromised if the night is not considered. Recent years, however, have seen a surge in research into the night. We argue that “night studies” is on the cusp of coming into its own as an interdisciplinary field, and that when it does, the field will consider questions that disciplinary researchers have not yet thought to ask

    Recommendations of protective measures for orthopedic surgeons during COVID-19 pandemic

    Get PDF
    PURPOSE: It was the primary purpose of the present systematic review to identify the optimal protection measures during COVID-19 pandemic and provide guidance of protective measures for orthopedic surgeons. The secondary purpose was to report the protection experience of an orthopedic trauma center in Wuhan, China during the pandemic. METHODS: A systematic search of the PubMed, Cochrane, Web of Science, Google Scholar was performed for studies about COVID-19, fracture, trauma, orthopedic, healthcare workers, protection, telemedicine. The appropriate protective measures for orthopedic surgeons and patients were reviewed (on-site first aid, emergency room, operating room, isolation wards, general ward, etc.) during the entire diagnosis and treatment process of traumatic patients. RESULTS: Eighteen studies were included, and most studies (13/18) emphasized that orthopedic surgeons should pay attention to prevent cross-infection. Only four studies have reported in detail how orthopedic surgeons should be protected during surgery in the operating room. No detailed studies on multidisciplinary cooperation, strict protection, protection training, indications of emergency surgery, first aid on-site and protection in orthopedic wards were found. CONCLUSION: Strict protection at every step in the patient pathway is important to reduce the risk of cross-infection. Lessons learnt from our experience provide some recommendations of protective measures during the entire diagnosis and treatment process of traumatic patients and help others to manage orthopedic patients with COVID-19, to reduce the risk of cross-infection between patients and to protect healthcare workers during work. LEVEL OF EVIDENCE: IV

    Reflectance spectra of synthetic Fe-free ortho- and clinoenstatites in the UV/ VIS/IR and implications for remote sensing detection of Fe-free pyroxenes on planetary surfaces

    Get PDF
    For a better spectral characterization of planetary bodies with enstatite-rich surfaces like Mercury or E-type asteroids, we synthesized two different enstatite (Mg2Si2O6) polymorphs: Orthoenstatite and clinoenstatite. Both enstatite polymorphs are known from the meteorite record and are commonly observed in aubrites and enstatite chondrites. The synthesized enstatites are particulate samples suitable for laboratory reflectance measurements and can be used for compositional modelling by preparing mixtures of samples in the laboratory or by using the sample's spectra in mathematical models. We report on the synthesis process, chemical composition, grain size distribution, and reflectance spectra of these synthetic enstatites covering the wavelength range from 0.25 to 17 μm, compare them to other pyroxenes (meteoritic enstatite and other synthetic enstatites and diopside), and discuss the implications of retrieving surface compositions of planetary bodies like E-type asteroids, comets, or Mercury. Both enstatite spectra are very bright in the VIS and NIR and show almost neutral to slightly bluish spectral slopes with a steep absorption in the UV. Very low iron in the enstatites (below ~0.04 wt% FeO) already results in weak albeit noticeable absorptions in the VNIR between 0.4 and 0.9 μm. Orthoenstatite and clinoenstatite are not distinguishable based only on their spectra in the VIS and NIR. At the Reststrahlen bands in the MIR a systematic difference in the number and exact position of local minima at ~10 μm between clinoenstatite and orthoenstatite is evident. This can be used to discern between the polymorphs in this wavelength range. Additionally, we can distinguish between Fe-free low- and high-Ca pyroxenes in the MIR
    corecore