1,355 research outputs found

    Deformations of the Boson sp(4,R)sp(4,R) Representation and its Subalgebras

    Full text link
    The boson representation of the sp(4,R) algebra and two distinct deformations of it, are considered, as well as the compact and noncompact subalgebras of each. The initial as well as the deformed representations act in the same Fock space. One of the deformed representation is based on the standard q-deformation of the boson creation and annihilation operators. The subalgebras of sp(4,R) (compact u(2) and three representations of the noncompact u(1,1) are also deformed and are contained in this deformed algebra. They are reducible in the action spaces of sp(4,R) and decompose into irreducible representations. The other deformed representation, is realized by means of a transformation of the q-deformed bosons into q-tensors (spinor-like) with respect to the standard deformed su(2). All of its generators are deformed and have expressions in terms of tensor products of spinor-like operators. In this case, an other deformation of su(2) appears in a natural way as a subalgebra and can be interpreted as a deformation of the angular momentum algebra so(3). Its representation is reducible and decomposes into irreducible ones that yields a complete description of the same

    Antiphospholipid Syndrome in Acute Cerebral Blood Flow Disorders

    Get PDF
    The purpose of the present study was to dynamically analyze the role of antiphospholipid syndrome in patients with acute disturbances of cerebral blood flow. Twenty-eight patients (16 females and 12 males) aged between 47 and 61 years were examined. The following criteria for patient's incorporation into the study were observed: presence of a focal neurological deficit, ultrasonographic evidence of disturbed cerebral blood flow, CT or MRI data about brain stroke. According to the data from the clinical or x-ray examination, the patients were divided into three groups: with hemorrhagic, embolic, or thrombotic stroke. Anticardiolipid (aCL) antibodies were assessed by ELISA method for a 12-month period. Elevated titres of aCL antibodies were proved in 12 patients (in 43 per cent of the cases) - in ten with ischemic and in two - with hemorrhagic stroke. The treatment with neuroprotective, antiaggregation and immunomodulatory means resulted in improvement of the clinical symptoms and antiphospholipid syndrome as well. It could be concluded that the summarized clinical, roentgenological and immunological data suggest the involvement of elevated titres of aCL antibodies into the pathogenesis of the acute cerebral blood flow disorders. The estimation of these antibodies should be considered obligatory in the patients with stroke with a view to enlargement of the prognostic criteria and more adequate therapeutic approach

    q-Analogue of Am−1⊕An−1⊂Amn−1A_{m-1}\oplus A_{n-1}\subset A_{mn-1}

    Full text link
    A natural embedding Am−1⊕An−1⊂Amn−1A_{m-1}\oplus A_{n-1}\subset A_{mn-1} for the corresponding quantum algebras is constructed through the appropriate comultiplication on the generators of each of the Am−1A_{m-1} and An−1A_{n-1} algebras. The above embedding is proved in their qq-boson realization by means of the isomorphism between the Aq−\mathcal{A}_q^{-} (mn)∼⊗nAq−\sim {\otimes} ^n \mathcal{A}_q^{-}(m)∼⊗mAq−\sim {\otimes}^m\mathcal{A}_q^{-}(n) algebras.Comment: 11 pages, no figures. In memory of professor R. P. Rousse

    Miniaturized Gas Correlation Radiometer for the Detection of Trace Gases in the Martian Atmosphere

    Get PDF
    We present a miniaturized and simplified version of a gas correlation radiometer (GCR) capable of simultaneously mapping multiple trace gases and identifying active regions on the Mars surface. Gas correlation radiometry (GCR) has been shown to be a sensitive and versatile method for detecting trace gases in Earth's atmosphere. Reduction of the size and mass of the GCR was achieved by implementing compact, light-weight 1 mm inner diameter hollow-core optical fibers (hollow waveguides) as the gas correlation cells. In a comparison with an Earth orbiting CO2 GCR instrument, exchanging the 10 m multipass cells with hollow waveguide gas correlation cells of equivalent path length reduces the mass from approximately 150 kg to approximately 0.5 kg, and reduces the volume from 1.9 m x 1.3 m x 0.86 m to a small bundle of fiber coils approximately 1 meter in diameter by 0.05 m in height (mass and volume reductions of greater than 99%). A unique feature of this instrument is its stackable module design, with a single module for each trace gas. Each of the modules is self-contained, and fundamentally identical; differing by the bandpass filter wavelength range and gas mixtures inside the hollow-waveguide absorption cells. The current configuration contains four stacked modules for simultaneous measurements of methane (CH4), formaldehyde (H2CO), water vapor (H2O), and deuterated water vapor (HDO) but could easily be expanded to include measurements of additional species of interest including nitrous oxide (N2O), hydrogen sulfide (H2S), methanol (CH3OH), and sulfur dioxide (SO2), as well as carbon dioxide (CO2) for a simultaneous measure of mass balance. Preliminary results indicate that a 1 ppb detection limit is possible for both formaldehyde and methane with one second of averaging. Using non-optimized components, we have demonstrated an instrument sensitivity equivalent to approximately 30 ppb for formaldehyde, and approximately 500 ppb for methane. We expect custom bandpass filters and 6 m long waveguides to significantly improve these promising results. Ongoing testing is being conducted on water vapor and deuterated water vapor

    Characterization of thin MoO3 films formed by RF and DC-magnetron reactive sputtering for gas sensor applications

    Get PDF
    The present work discusses a technology f or deposition and characterization of thin molybdenum oxide (MoO x , MoO 3 ) films studied for gas sensor applications. T he samples were produced by reactive radio - frequency (RF) and direct c urrent (DC) magnetron sputtering. The composition and microstructure of the films were studied by XPS , XRD and Raman spectroscopy, the morphology , using high resolution SEM. T he research was focused on the sensing properties of the sputtered thin MoO 3 films. Highly sensitive gas sensor s were implemented by depositing films of various thicknesses on quartz resonators. Making use of the quartz crystal microbalance (QCM) method , the se sensors we re capable of detect ing chan ges in the molecular range. Prototype QCM structures with thin MoO 3 films were tested for sensitivity to NH 3 and NO 2 . E ven in as - deposited state and without heating the substrates, these films show ed good sensitivity . Moreover , no a dditional thermal treatment is necessary, which makes the production of such QCM gas sensor s simple and cost - effective, as it is fu lly compatible wit h the technology for producing t he initial resonator . Т he films are sensitive at room temperature and can reg ister concentrations as low as 50 ppm . The sorption is fully reversible , the films are stable and capable of long - term measuremen ts

    Immobilization of Trichosporon cutaneum R 57 Cells onto Methylcellulose/SiO2 Hybrids and Biosorption of Cadmium and Copper Ions

    Get PDF
    Methylcellulose/Silica (MC/SiO2) hybrids were synthesized via poly step sol-gel method. SiO2 was included into the hybrids from two silica precursors - methyltriethoxysilane (MTES) and ethyltrimethoxysilane (ETMS) with different quantity of organic part-5, 20 and 50 wt.%. The filamentous yeasts Trichosporon cutaneum strain R 57 was immobilized onto the synthesized MC/SiO2 hybrids. After immobilization the hybrid materials were used in the processes of sorption of cadmium and copper ions. The obtained results of protein content analysis indicated that the amount of protein increased with increasing of MC in the hybrids. It was established that the maximal efficiency of copper and cadmium removal were observed for hybrid materials containing MTES and 50 wt.% MC - 66% and 26% respectively. For ETMS and 50 wt.% MC a high value of copper removal was 56% and for cadmium - 45% removal, respectively. FTIR analysis of free and immobilized cells with metal ions was conducted. SEM images showed successful immobilization of the yeasts cells. Second order model was employed in order to investigate the kinetics of copper and cadmium biosorption
    • …
    corecore