165 research outputs found

    Three-centre cluster structure in 11C and 11B

    Full text link
    Studies of the 16O(9Be,alpha 7Be)14C, 7Li(9Be,alpha 7Li)5He and 7Li(9Be,alpha alpha t)5He reactions at E(beam)=70 and 55 MeV have been performed using resonant particle spectroscopy techniques. The 11C excited states decaying into alpha+7Be(gs) are observed between 8.5 and 13.5 MeV. The alpha+7Li(gs), alpha+7Li*(4.652 MeV) and t+8Be(gs) decays of 11B excited states between 9 and 19 MeV are observed. The decay processes are used to indicate the possible three-centre 2alpha+3He (2alpha+3H) cluster structure of observed states. This cluster structure is more prominent in the positive-parity states, where two rotational bands with large deformations are suggested. Excitations of some of the observed T=1/2 resonances coincide with the energies of previously measured T=3/2 isobaric analogs of the 11Be states,indicating that these states may have mixed isospin.Comment: Contribution for the proceedings of the NUSTAR'05: NUclear STructure, Astrophysics and Reactions, University of Surrey, Guildford, UK; accepted for publication in Journal of Physics

    An overview on extremity dosimetry in medical applications

    Get PDF
    Some activities of EURADOS Working Group 9 (WG9) are presently funded by the European Commission (CONRAD project). The objective of WG9 is to promote and co-ordinate research activities for the assessment of occupational exposures to staff at workplaces in interventional radiology (IR) and nuclear medicine. For some of these applications, the skin of the fingers is the limiting organ for individual monitoring of external radiation. Therefore, sub-group 1 of WG9 deals with the use of extremity dosemeters in medical radiation fields. The wide variety of radiation field characteristics present in a medical environment together with the difficulties in measuring a local dose that is representative for the maximum skin dose, usually with one single detector, makes it difficult to perform accurate extremity dosimetry. Sub-group 1 worked out a thorough literature review on extremity dosimetry issues in diagnostic and therapeutic nuclear medicine and positron emission tomography, interventional radiology and interventional cardiology and brachytherapy. Some studies showed that the annual dose limits could be exceeded if the required protection measures are not taken, especially in nuclear medicine. The continuous progress in new applications and techniques requires an important effort in radiation protection and trainin

    An overview of the use of extremity dosemeters in some European countries for medical applications

    Get PDF
    Some medical applications are associated with high doses to the extremities of the staff exposed to ionising radiation. At workplaces in nuclear medicine, interventional radiology, interventional cardiology and brachytherapy, extremities can be the limiting organs as far as regulatory dose limits for workers are concerned. However, although the need for routine extremity monitoring is clear for these applications, no data about the status of routine extremity monitoring reported by different countries was collected and analysed so far, at least at a European level. In this article, data collected from seven European countries are presented. They are compared with extremity doses extracted from dedicated studies published in the literature which were reviewed in a previous publication. The analysis shows that dedicated studies lead to extremity doses significantly higher than the reported doses, suggesting that either the most exposed workers are not monitored, or the dosemeters are not routinely worn or not worn at appropriate position

    Evolution of shell structure in neutron-rich calcium isotopes

    Full text link
    We employ interactions from chiral effective field theory and compute the binding energies and low-lying excitations of calcium isotopes with the coupled-cluster method. Effects of three-nucleon forces are included phenomenologically as in-medium two-nucleon interactions, and the coupling to the particle continuum is taken into account using a Berggren basis. The computed ground-state energies and the low-lying 2+ states for the isotopes 42,48,50,52Ca are in good agreement with data, and we predict the excitation energy of the first 2+ state in 54Ca at 1.9 MeV, displaying only a weak sub-shell closure. In the odd-mass nuclei 53,55,61Ca we find that the positive parity states deviate strongly from the naive shell model.Comment: 5 pages, 4 figures; small correction of effective 3NF and slight change of the corresponding parameters; updated figures and tables; main results and conclusions unchange

    Light-particle emission from the fissioning nuclei 126Ba, 188Pt and (266,272,278)/110: theoretical predictions and experimental results

    Full text link
    We present a comparison of our model treating fission dynamics in conjunction with light-particle (n, p, alpha) evaporation with the available experimental data for the nuclei 126Ba, 188Pt and three isotopes of the element Z=110. The dynamics of the symmetric fission process is described through the solution of a classical Langevin equation for a single collective variable characterizing the nuclear deformation along the fission path. A microscopic approach is used to evaluate the emission rates for pre-fission light particles. Entrance-channel effects are taken into account by generating an initial spin distribution of the compound nucleus formed by the fusion of two deformed nuclei with different relative orientations

    Strongly damped nuclear collisions: zero or first sound ?

    Get PDF
    The relaxation of the collective quadrupole motion in the initial stage of a central heavy ion collision at beam energies Elab=5Ă·20E_{lab}=5\div20 AMeV is studied within a microscopic kinetic transport model. The damping rate is shown to be a non-monotonic function of E_{lab} for a given pair of colliding nuclei. This fact is interpreted as a manifestation of the zero-to-first sound transition in a finite nuclear system.Comment: 15 pages, 4 figure

    Active personal dosemeters in interventional radiology: tests in laboratory conditions and in hospitals

    Get PDF
    The work package 3 of the ORAMED project, Collaborative Project (2008-11) supported by the European Commission within its seventh Framework Programme, is focused on the optimisation of the use of active personal dosemeters (APDs) in interventional radiology and cardiology (IR/IC). Indeed, a lack of appropriate APD devices is identified for these specific fields. Few devices can detect low-energy X rays (20-100 keV), and none of them are specifically designed for working in pulsed radiation fields. The work presented in this paper consists in studying the behaviour of some selected APDs deemed suitable for application in IR/IC. For this purpose, measurements under laboratory conditions, both with continuous and pulsed X-ray beams, and tests in real conditions on site in different European hospitals were performed. This study highlights the limitations of APDs for this application and the need of improving the APD technology so as to fulfil all needs in the IR/IC fiel

    4He decay of excited states in 14C

    Full text link
    A study of the 7Li(9Be,4He 10Be)2H reaction at E{beam}=70 MeV has been performed using resonant particle spectroscopy techniques and provides the first measurements of alpha-decaying states in 14C. Excited states are observed at 14.7, 15.5, 16.4, 18.5, 19.8, 20.6, 21.4, 22.4 and 24.0 MeV. The experimental technique was able to resolve decays to the various particle bound states in 10Be, and provides evidence for the preferential decay of the high energy excited states into states in 10Be at ~6 MeV. The decay processes are used to indicate the possible cluster structure of the 14C excited states.Comment: accepted for publication in PR

    Extremity ring dosimetry intercomparison in reference and workplace fields

    Get PDF
    An intercomparison of ring dosemeters has been organised with the aim of assessing the technical capabilities of available extremity dosemeters and focusing on their performance at clinical workplaces with potentially high extremity doses. Twenty-four services from 16 countries participated in the intercomparison. The dosemeters were exposed to reference photon (137Cs) and beta (147Pm, 85Kr and 90Sr/90Y) fields together with fields representing realistic exposure situations in interventional radiology (direct and scattered radiation) and nuclear medicine (99 mTc and 18F). It has been found that most dosemeters provided satisfactory measurements of Hp(0.07) for photon radiation, both in reference and realistic fields. However, only four dosemeters fulfilled the established requirements for all radiation qualities. The main difficulties were found for the measurement of low-energy beta radiation. Finally, the results also showed a general under-response of detectors to 18F, which was attributed to the difficulties of the dosimetric systems to measure the positron contribution to the dos
    • …
    corecore