144 research outputs found

    When global climate models are able to differentiate between an elephant and a big mouse

    Get PDF
    Um alle 2,5 Kilometer auf der Erde den Zustand der Atmosphäre mit einem Klimamodell nachzurechnen, braucht es 83 Millionen Punkte. Nur so, und im Gegensatz zu gängigen Klimamodellen, die mit einer typischen Auflösung von rund 100 Kilometer arbeiten, lässt sich die Vielfalt der Wolken und ihre einzigartigen Formen, die manchmal an einen Elefanten, manchmal an eine große Maus erinnern, wiedergeben. Sind aber so viele Details nötig? Die Autoren präsentieren die Ergebnisse einer internationalen Vergleichsstudie, in der zum ersten Mal acht solcher neuartigen Klimamodelle gerechnet wurden.Eighty-three million points are needed to represent the atmospheric state every 2.5 km on Earth. Only such a grid spacing allows climate modelers to represent in their models the diversity of clouds, their small-scale details and their unique shapes which, at times, may remember elephants and, at other times, big mice. But are so many details that cannot be captured by current state-of-the-art climate models really necessary? In the following the authors present the results of an intercomparison exercise where, for the first time, eight of these next-generation climate models were run

    Left atrial appendage volume is an independent predictor of atrial arrhythmia recurrence following cryoballoon pulmonary vein isolation in persistent atrial fibrillation

    Get PDF
    PurposePulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation in persistent AF (persAF), and cryoballoon PVI emerged as an initial ablation strategy. Symptomatic atrial arrhythmia recurrence following successful PVI in persAF is observed more frequently than in paroxysmal AF. Predictors for arrhythmia recurrence following cryoballoon PVI for persAF are not well described, and the role of left atrial appendage (LAA) anatomy is uncertain.MethodsPatients with symptomatic persAF and pre-procedural cardiac computed tomography angiography (CCTA) images undergoing initial second-generation cryoballoon (CBG2) were enrolled. Left atrial (LA), pulmonary vein (PV) and LAA anatomical data were assessed. Clinical outcome and predictors for atrial arrhythmia recurrence were evaluated by univariate and multivariate regression analysis.ResultsFrom May 2012 to September 2016, 488 consecutive persAF patients underwent CBG2-PVI. CCTA with sufficient quality for measurements was available in 196 (60.4%) patients. Mean age was 65.7 ± 9.5 years. Freedom from arrhythmia was 58.2% after a median follow-up of 19 (13; 29) months. No major complications occurred. Independent predictors for arrhythmia recurrence were LAA volume (HR 1.082; 95% CI, 1.032 to 1.134; p = 0.001) and mitral regurgitation ≥ grade 2 (HR, 2.49; 95% CI 1.207 to 5.126; p = 0.013). LA volumes ≥110.35 ml [sensitivity: 0.81, specificity: 0.40, area under the curve (AUC) = 0.62] and LAA volumes ≥9.75 ml (sensitivity: 0.56, specificity 0.70, AUC = 0.64) were associated with recurrence. LAA-morphology, classified as chicken-wing (21.9%), windsock (52.6%), cactus (10.2%) and cauliflower (15.3%), did not predict outcome (log-rank, p = 0.832).ConclusionLAA volume and mitral regurgitation were independent predictors for arrhythmia recurrence following cryoballoon ablation in persAF. LA volume was less predictive and correlated with LAA volume. LAA morphology did not predict the clinical outcome. To improve outcomes in persAF ablation, further studies should focus on treatment strategies for persAF patients with large LAA and mitral regurgitation

    Solution nuclear magnetic resonance spectroscopy on a nanostructured diamond chip

    Get PDF
    Sensors using nitrogen-vacancy centers in diamond are a promising tool for small-volume nuclear magnetic resonance (NMR) spectroscopy, but the limited sensitivity remains a challenge. Here we show nearly two orders of magnitude improvement in concentration sensitivity over previous nitrogen-vacancy and picoliter NMR studies. We demonstrate NMR spectroscopy of picoliter-volume solutions using a nanostructured diamond chip with dense, high-aspect-ratio nanogratings, enhancing the surface area by 15 times. The nanograting sidewalls are doped with nitrogen-vacancies located a few nanometers from the diamond surface to detect the NMR spectrum of roughly 1 pl of fluid lying within adjacent nanograting grooves. We perform 1H and 19F nuclear magnetic resonance spectroscopy at room temperature in magnetic fields below 50 mT. Using a solution of CsF in glycerol, we determine that 4 ± 2 × 1012 19F spins in a 1 pl volume can be detected with a signal-to-noise ratio of 3 in 1 s of integration

    The epitaxy of gold

    Full text link
    • …
    corecore