95 research outputs found

    Spreading continents kick-started plate tectonics

    Get PDF
    International audienceStresses acting on cold, thick and negatively buoyant oceanic litho- sphere are thought to be crucial to the initiation of subduction and the operation of plate tectonics, which characterizes the present- day geodynamics of the Earth. Because the Earth’s interior was hotter in the Archaean eon, the oceanic crust may have been thicker, thereby making the oceanic lithosphere more buoyant than at present, and whether subduction and plate tectonics occurred during this time is ambiguous, both in the geological record and in geodynamic models. Here we show that because the oceanic crust was thick and buoyant5, early continents may have produced intra-lithospheric gravitational stresses large enough to drive their gravitational spreading, to initiate subduction at their margins and to trigger episodes of subduction. Our model predicts the co-occurrence of deep to progressively shallower mafic volcanics and arc magmatism within continents in a self-consistent geodynamic framework, explaining the enigmatic multimodal volcanism and tectonic record of Archaean cratons. Moreover, our model predicts a petrological stratification and tectonic structure of the sub-continental lithospheric mantle, two predictions that are consistent with xenolith and seismic studies, respectively, and consistent with the existence of a mid-lithospheric seismic discontinuity. The slow gravitational collapse of early continents could have kick-started transient episodes of plate tectonics until, as the Earth’s interior cooled and oceanic lithosphere became heavier, plate tectonics became self-sustaining

    Transcriptome and Proteome Exploration to Model Translation Efficiency and Protein Stability in Lactococcus lactis

    Get PDF
    This genome-scale study analysed the various parameters influencing protein levels in cells. To achieve this goal, the model bacterium Lactococcus lactis was grown at steady state in continuous cultures at different growth rates, and proteomic and transcriptomic data were thoroughly compared. Ratios of mRNA to protein were highly variable among proteins but also, for a given gene, between the different growth conditions. The modeling of cellular processes combined with a data fitting modeling approach allowed both translation efficiencies and degradation rates to be estimated for each protein in each growth condition. Estimated translational efficiencies and degradation rates strongly differed between proteins and were tested for their biological significance through statistical correlations with relevant parameters such as codon or amino acid bias. These efficiencies and degradation rates were not constant in all growth conditions and were inversely proportional to the growth rate, indicating a more efficient translation at low growth rate but an antagonistic higher rate of protein degradation. Estimated protein median half-lives ranged from 23 to 224 min, underlying the importance of protein degradation notably at low growth rates. The regulation of intracellular protein level was analysed through regulatory coefficient calculations, revealing a complex control depending on protein and growth conditions. The modeling approach enabled translational efficiencies and protein degradation rates to be estimated, two biological parameters extremely difficult to determine experimentally and generally lacking in bacteria. This method is generic and can now be extended to other environments and/or other micro-organisms

    Women’s, partners’ and healthcare providers’ views and experiences of assisted vaginal birth: a systematic mixed methods review

    Get PDF
    Background When certain complications arise during the second stage of labour, assisted vaginal delivery (AVD), a vaginal birth with forceps or vacuum extractor, can effectively improve outcomes by ending prolonged labour or by ensuring rapid birth in response to maternal or fetal compromise. In recent decades, the use of AVD has decreased in many settings in favour of caesarean section (CS). This review aimed to improve understanding of experiences, barriers and facilitators for AVD use. Methods Systematic searches of eight databases using predefined search terms to identify studies reporting views and experiences of maternity service users, their partners, health care providers, policymakers, and funders in relation to AVD. Relevant studies were assessed for methodological quality. Qualitative findings were synthesised using a meta-ethnographic approach. Confidence in review findings was assessed using GRADE CERQual. Findings from quantitative studies were synthesised narratively and assessed using an adaptation of CERQual. Qualitative and quantitative review findings were triangulated using a convergence coding matrix. Results Forty-two studies (published 1985–2019) were included: six qualitative, one mixed-method and 35 quantitative. Thirty-five were from high-income countries, and seven from LMIC settings. Confidence in the findings was moderate or low. Spontaneous vaginal birth was most likely to be associated with positive short and long-term outcomes, and emergency CS least likely. Views and experiences of AVD tended to fall somewhere between these two extremes. Where indicated, AVD can be an effective, acceptable alternative to caesarean section. There was agreement or partial agreement across qualitative studies and surveys that the experience of AVD is impacted by the unexpected nature of events and, particularly in high-income settings, unmet expectations. Positive relationships, good communication, involvement in decision-making, and (believing in) the reason for intervention were important mediators of birth experience. Professional attitudes and skills (development) were simultaneously barriers and facilitators of AVD in quantitative studies. Conclusions Information, positive interaction and communication with providers and respectful care are facilitators for acceptance of AVD. Barriers include lack of training and skills for decision-making and use of instruments

    Delphi consensus statement on intrapartum fetal monitoring in low-resource settings

    Get PDF
    OBJECTIVE: To determine acceptable and achievable strategies of intrapartum fetal monitoring in busy low-resource settings. METHODS: Three rounds of online Delphi surveys were conducted between January 1 and October 31, 2017. International experts with experience in low-resource settings scored the importance of intrapartum fetal monitoring methods. RESULTS: 71 experts completed all three rounds (28 midwives, 43 obstetricians). Consensus was reached on (1) need for an admission test, (2) handheld Doppler for intrapartum fetal monitoring, (3) intermittent auscultation (IA) every 30 minutes for low-risk pregnancies during the first stage of labor and after every contraction for high-risk pregnancies in the second stage, (4) contraction monitoring hourly for low-risk pregnancies in the first stage, and (5) adjunctive tests. Consensus was not reached on frequency of IA or contraction monitoring for high-risk women in the first stage or low-risk women in the second stage of labor. CONCLUSION: There is a gap between international recommendations and what is physically possible in many labor wards in low-resource settings. Research on how to effectively implement the consensus on fetal assessment at admission and use of handheld Doppler during labor and delivery is crucial to support staff in achieving the best possible care in low-resource settings
    • …
    corecore