30 research outputs found

    The role and performance of chest X-ray for the diagnosis of tuberculosis: A cost-effectiveness analysis in Nairobi, Kenya

    Get PDF
    BACKGROUND: The objective of this study was to establish 1) the performance of chest X-ray (CXR) in all suspects of tuberculosis (TB), as well as smear-negative TB suspects and 2) to compare the cost-effectiveness of the routine diagnostic pathway using Ziehl-Neelsen (ZN) sputum microscopy followed by CXR if case of negative sputum result (ZN followed by CXR) with an alternative pathway using CXR as a screening tool (CXR followed by ZN). METHODS: From TB suspects attending a chest clinic in Nairobi, Kenya, three sputum specimens were examined for ZN and culture (Lowenstein Jensen). Culture was used as gold standard. From each suspect a CXR was made using a four point scoring system: i: no pathology, ii: pathology not consistent for TB, iii: pathology consistent for TB and iv: pathology highly consistent for TB. The combined score i + ii was labeled as "no TB" and the combined score iii + iv was labeled as "TB". Films were re-read by a reference radiologist. HIV test was performed on those who consented. Laboratory and CXR costs were used to compare for cost-effectiveness. RESULTS: Of the 1,389 suspects enrolled, for 998 (72%) data on smear, culture and CXR was complete. 714 films were re-read, showing a 89% agreement (kappa value = 0.75 s.e.0.037) for the combined scores "TB" or "no-TB". The sensitivity/specificity of the CXR score "TB" among smear-negative suspects was 80%/67%. Using chest CXR as a screening tool in all suspects, sensitivity/specificity of the score "any pathology" was 92%, respectively 63%. The cost per correctly diagnosed case was for the routine process 8.72,comparedto8.72, compared to 9.27 using CXR as screening tool. When costs of treatment were included, CXR followed by ZN became more cost-effective. CONCLUSION: The diagnostic pathway ZN followed by CXR was more cost-effective as compared to CXR followed by ZN. When cost of treatment was also considered CXR followed by ZN became more cost-effective. The low specificity of chest X-ray remains a subject of concern. Depending whether CXR was performed on all suspects or on smear-negative suspects only, 22%–45% of patients labeled as "TB" had a negative culture. The introduction of a well-defined scoring system, clinical conferences and a system of CXR quality control can contribute to improved diagnostic performance

    Cost-effectiveness analysis of PCR for the rapid diagnosis of pulmonary tuberculosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tuberculosis is one of the most prominent health problems in the world, causing 1.75 million deaths each year. Rapid clinical diagnosis is important in patients who have co-morbidities such as Human Immunodeficiency Virus (HIV) infection. Direct microscopy has low sensitivity and culture takes 3 to 6 weeks <abbrgrp><abbr bid="B1">1</abbr><abbr bid="B2">2</abbr><abbr bid="B3">3</abbr></abbrgrp>. Therefore, new tools for TB diagnosis are necessary, especially in health settings with a high prevalence of HIV/TB co-infection.</p> <p>Methods</p> <p>In a public reference TB/HIV hospital in Brazil, we compared the cost-effectiveness of diagnostic strategies for diagnosis of pulmonary TB: Acid fast bacilli smear microscopy by Ziehl-Neelsen staining (AFB smear) plus culture and AFB smear plus colorimetric test (PCR dot-blot).</p> <p>From May 2003 to May 2004, sputum was collected consecutively from PTB suspects attending the Parthenon Reference Hospital. Sputum samples were examined by AFB smear, culture, and PCR dot-blot. The gold standard was a positive culture combined with the definition of clinical PTB. Cost analysis included health services and patient costs.</p> <p>Results</p> <p>The AFB smear plus PCR dot-blot require the lowest laboratory investment for equipment (US20,000).Thetotalscreeningcostsare3.8timesforAFBsmearpluscultureversusforAFBsmearplusPCRdotblotcosts(US 20,000). The total screening costs are 3.8 times for AFB smear plus culture versus for AFB smear plus PCR dot blot costs (US 5,635,760 versus US1,498,660).CostspercorrectlydiagnosedcasewereUS 1,498, 660). Costs per correctly diagnosed case were US 50,773 and US13,749forAFBsmearpluscultureandAFBsmearplusPCRdot−blot,respectively.AFBsmearplusPCRdot−blotwasmorecost−effectivethanAFBsmearplusculture,whenthecostoftreatingallcorrectlydiagnosedcaseswasconsidered.Thecostofreturningpatients,whicharenottreatedduetoanegativeresult,tothehealthservice,washigherinAFBsmearplusculturethanforAFBsmearplusPCRdot−blot,US 13,749 for AFB smear plus culture and AFB smear plus PCR dot-blot, respectively. AFB smear plus PCR dot-blot was more cost-effective than AFB smear plus culture, when the cost of treating all correctly diagnosed cases was considered. The cost of returning patients, which are not treated due to a negative result, to the health service, was higher in AFB smear plus culture than for AFB smear plus PCR dot-blot, US 374,778,045 and US$ 110,849,055, respectively.</p> <p>Conclusion</p> <p>AFB smear associated with PCR dot-blot associated has the potential to be a cost-effective tool in the fight against PTB for patients attended in the TB/HIV reference hospital.</p

    Portable, Battery-Operated, Low-Cost, Bright Field and Fluorescence Microscope

    Get PDF
    This study describes the design and evaluation of a portable bright-field and fluorescence microscope that can be manufactured for $240 USD. The microscope uses a battery-operated LED-based flashlight as the light source and achieves a resolution of 0.8 µm at 1000× magnification in fluorescence mode. We tested the diagnostic capability of this new instrument to identify infections caused by the human pathogen, Mycobacterium tuberculosis. Sixty-four direct, decontaminated, and serially diluted smears were prepared from sputa obtained from 19 patients suspected to have M. tuberculosis infection. Slides were stained with auramine orange and evaluated as being positive or negative for M. tuberculosis with both the new portable fluorescence microscope and a laboratory grade fluorescence microscope. Concordant results were obtained in 98.4% of cases. This highly portable, low cost, fluorescence microscope may be a useful diagnostic tool to expand the availability of M. tuberculosis testing at the point-of-care in low resource settings

    Nucleic Acid Amplification Tests for Diagnosis of Smear-Negative TB in a High HIV-Prevalence Setting: A Prospective Cohort Study

    Get PDF
    Nucleic acid amplification tests are sensitive for identifying Mycobacterium tuberculosis in populations with positive sputum smears for acid-fast bacilli, but less sensitive in sputum-smear-negative populations. Few studies have evaluated the clinical impact of these tests in low-income countries with high burdens of TB and HIV.We prospectively enrolled 211 consecutive adults with cough ≥2 weeks and negative sputum smears at Mulago Hospital in Kampala, Uganda. We tested a single early-morning sputum specimen for Mycobacterium tuberculosis DNA using two nucleic acid amplification tests: a novel in-house polymerase chain reaction targeting the mycobacterial secA1 gene, and the commercial Amplified® Mycobacterium tuberculosis Direct (MTD) test (Gen-Probe Inc, San Diego, CA). We calculated the diagnostic accuracy of these index tests in reference to a primary microbiologic gold standard (positive mycobacterial culture of sputum or bronchoalveolar lavage fluid), and measured their likely clinical impact on additional tuberculosis cases detected among those not prescribed initial TB treatment.Of 211 patients enrolled, 170 (81%) were HIV-seropositive, with median CD4+ T-cell count 78 cells/µL (interquartile range 29-203). Among HIV-seropositive patients, 94 (55%) reported taking co-trimoxazole prophylaxis and 29 (17%) reported taking antiretroviral therapy. Seventy-five patients (36%) had culture-confirmed TB. Sensitivity of MTD was 39% (95% CI 28-51) and that of secA1 was 24% (95% CI 15-35). Both tests had specificities of 95% (95% CI 90-98). The MTD test correctly identified 18 (24%) TB patients not treated at discharge and led to a 72% relative increase in the smear-negative case detection rate.The secA1 and MTD nucleic acid amplification tests had moderate sensitivity and high specificity for TB in a predominantly HIV-seropositive population with negative sputum smears. Although newer, more sensitive nucleic acid assays may enhance detection of Mycobacterium tuberculosis in sputum, even currently available tests can provide substantial clinical impact in smear-negative populations

    PCR colorimetric dot-blot assay and clinical pretest probability for diagnosis of Pulmonary Tuberculosis in Smear-Negative patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Smear-negative pulmonary tuberculosis (SNPTB) accounts for 30% of Pulmonary Tuberculosis (PTB) cases reported annually in developing nations. Polymerase chain reaction (PCR) may provide an alternative for the rapid detection of <it>Mycobacterium tuberculosis </it>(MTB); however little data are available regarding the clinical utility of PCR in SNPTB, in a setting with a high burden of TB/HIV co-infection.</p> <p>Methods</p> <p>To evaluate the performance of the PCR dot-blot in parallel with pretest probability (Clinical Suspicion) in patients suspected of having SNPTB, a prospective study of 213 individuals with clinical and radiological suspicion of SNPTB was carried out from May 2003 to May 2004, in a TB/HIV reference hospital. Respiratory specialists estimated the pretest probability of active disease into high, intermediate, low categories. Expectorated sputum was examined by direct microscopy (Ziehl-Neelsen staining), culture (Lowenstein Jensen) and PCR dot-blot. Gold standard was based on culture positivity combined with the clinical definition of PTB.</p> <p>Results</p> <p>In smear-negative and HIV subjects, active PTB was diagnosed in 28.4% (43/151) and 42.2% (19/45), respectively. In the high, intermediate and low pretest probability categories active PTB was diagnosed in 67.4% (31/46), 24% (6/25), 7.5% (6/80), respectively. PCR had sensitivity of 65% (CI 95%: 50%–78%) and specificity of 83% (CI 95%: 75%–89%). There was no difference in the sensitivity of PCR in relation to HIV status. PCR sensitivity and specificity among non-previously TB treated and those treated in the past were, respectively: 69%, 43%, 85% and 80%. The high pretest probability, when used as a diagnostic test, had sensitivity of 72% (CI 95%:57%–84%) and specificity of 86% (CI 95%:78%–92%). Using the PCR dot-blot in parallel with high pretest probability as a diagnostic test, sensitivity, specificity, positive and negative predictive values were: 90%, 71%, 75%, and 88%, respectively. Among non-previously TB treated and HIV subjects, this approach had sensitivity, specificity, positive and negative predictive values of 91%, 79%, 81%, 90%, and 90%, 65%, 72%, 88%, respectively.</p> <p>Conclusion</p> <p>PCR dot-blot associated with a high clinical suspicion may provide an important contribution to the diagnosis of SNPTB mainly in patients that have not been previously treated attended at a TB/HIV reference hospital.</p
    corecore