355 research outputs found

    Monovalent Ion Condensation at the Electrified Liquid/Liquid Interface

    Full text link
    X-ray reflectivity studies demonstrate the condensation of a monovalent ion at the electrified interface between electrolyte solutions of water and 1,2-dichloroethane. Predictions of the ion distributions by standard Poisson-Boltzmann (Gouy-Chapman) theory are inconsistent with these data at higher applied interfacial electric potentials. Calculations from a Poisson-Boltzmann equation that incorporates a non-monotonic ion-specific potential of mean force are in good agreement with the data.Comment: 4 pages, 4 figure

    Impact of fluctuations in gaseous H2S concentrations on sulfide uptake by sewer concrete: The effect of high H2S loads

    Get PDF
    The acid production from the oxidation of hydrogen sulfide (H2S) in sewer air results in serious corrosion of exposed concrete surfaces in sewers. Large fluctuations of gaseous H2S concentrations occur in sewers due to the diurnal profiles of sewage flow and retention times and the necessity of intermittent pumping of sewage from pressure pipes into gravity pipes. How the high concentrations of H2S due to these events may affect H2S uptake and subsequent corrosion by concrete sewers is largely unknown. This study determined the effect of short- and long-term increases in H2S levels on the sulfide uptake rate (SUR) of concrete surfaces with an active corrosion layer. The results showed that during the high load situation the SUR increased significantly but then decreased (compared to the baseline SUR) by about 7-14% and 41-50% immediately after short- and long-term H2S high-load periods, respectively. For both exposure conditions, the SUR gradually (over several hours) recovered to approximately 90% of the baseline SUR. Further tests suggest multiple factors may contribute to the observed decrease of SUR directly after the high H2S load. This includes the temporary storage of elemental sulfur in the corrosion layer and inhibition of sulfide oxidizing bacteria (SOB) due to high H2S level and temporary acid surge. Additionally, the delay of the corrosion layer to fully recover the SUR after the high H2S load suggests that there is a longer-term inhibitive effect of the high H2S levels on the activity of the SOB in the corrosion layer. Due to the observed activity reductions, concrete exposed to occasional short-term high H2S load periods had an overall lower H2S uptake compared to concrete exposed to constant H2S levels at the same average concentration. To accurately predict H2S uptake by sewer concrete and hence the likely maximum corrosion rates, a correction factor should be adopted for the H2S fluctuations when average H2S levels are used in the prediction. (C) 2015 Elsevier Ltd. All rights reserved

    Identification of controlling factors for the initiation of corrosion of fresh concrete sewers

    Get PDF
    The development of concrete corrosion in new sewer pipes undergoes an initiation process before reaching an active corrosion stage. This initiation period is assumed to last several months to years but the key factors affecting the process, and its duration, are not well understood. This study is therefore focused on this initial stage of the corrosion process and the effect of key environmental factors. Such knowledge is important for the effective management of corrosion in new sewers, as every year of life extension of such systems has a very high financial benefit. This long-term (4.5 year) study has been conducted in purpose-built corrosion chambers that closely simulated the sewer environment, but with control of three key environmental factors being hydrogen sulfide (H2S) gas phase concentration, relative humidity and air temperature. Fresh concrete coupons, cut from an industry-standard sewer pipe, were exposed to the corrosive conditions in the chambers, both in the gas phase and partially submerged in wastewater. A total of 36 exposure conditions were investigated to determine the controlling factors by regular retrieval of concrete coupons for detailed analysis of surface pH, sulfur compounds (elemental sulfur and sulfate) and concrete mass loss. Corrosion initiation times were thus determined for different exposure conditions. It was found that the corrosion initiation time of both gas-phase and partially-submerged coupons was positively correlated with the gas phase H2S concentration, but only at levels of 10 ppm or below, indicating that sulfide oxidation rate rather than the H2S concentration was the limiting factor during the initiation stage. Relative humidity also played a role for the corrosion initiation of the gas-phase coupons. However, the partially-submerged coupons were not affected by humidity as these coupons were in direct contact with the sewage and hence did have sufficient moisture to enable the microbial processes to proceed. The corrosion initiation time was also shortened by higher gas temperature due to its positive impact on reaction kinetics. These findings provide real opportunities for pro-active sewer asset management with the aim to delay the on-set of the corrosion processes, and hence extend the service life of sewers, through improved prediction and optimization capacity. (C) 2015 Elsevier Ltd. All rights reserved

    Application of digital PCR for public health-related water quality monitoring

    Get PDF
    Digital polymerase chain reaction (dPCR) is emerging as a reliable platform for quantifying microorganisms in the field of water microbiology. This paper reviews the fundamental principles of dPCR and its application for health-related water microbiology. The relevant literature indicates increasing adoption of dPCR for measuring fecal indicator bacteria, microbial source tracking marker genes, and pathogens in various aquatic environments. The adoption of dPCR has accelerated recently due to increasing use for wastewater surveillance of Severe Acute Respiratory Coronavirus 2 (SARS-CoV-2) -the virus that causes Coronavirus Disease 2019 (COVID-19). The collective experience in the scientific literature indicates that well-optimized dPCR assays can quantify genetic material from microorganisms without the need for a calibration curve and often with superior analytical performance (i.e., greater sensitivity, precision, and reproducibility) than quantitative polymerase chain reaction (qPCR). Nonetheless, dPCR should not be viewed as a panacea for the fundamental uncertainties and limitations associated with measuring microorganisms in water microbiology. With dPCR platforms, the sample analysis cost and processing time are typically greater than qPCR. However, if improved analytical performance (i.e., sensitivity and accuracy) is critical, dPCR can be an alternative option for quantifying microorganisms, including pathogens, in aquatic environments.Peer reviewe

    Zfp296 Is a Novel, Pluripotent-Specific Reprogramming Factor

    Get PDF
    Expression of the four transcription factors Oct4, Sox2, Klf4, and c-Myc (OSKM) is sufficient to reprogram somatic cells into induced pluripotent stem (iPSCs). However, this process is slow and inefficient compared with the fusion of somatic cells with embryonic stem cells (ESCs), indicating that ESCs express additional factors that can enhance the efficiency of reprogramming. We had previously developed a method to detect and isolate early neural induction intermediates during the differentiation of mouse ESCs. Using the gene expression profiles of these intermediates, we identified 23 ESC-specific transcripts and tested each for the ability to enhance iPSC formation. Of the tested factors, zinc finger protein 296 (Zfp296) led to the largest increase in mouse iPSC formation. We confirmed that Zfp296 was specifically expressed in pluripotent stem cells and germ cells. Zfp296 in combination with OSKM induced iPSC formation earlier and more efficiently than OSKM alone. Through mouse chimera and teratoma formation, we demonstrated that the resultant iPSCs were pluripotent. We showed that Zfp296 activates transcription of the Oct4 gene via the germ cell–specific conserved region 4 (CR4), and when overexpressed in mouse ESCs leads to upregulation of Nanog expression and downregulation of the expression of differentiation markers, including Sox17, Eomes, and T, which is consistent with the observation that Zfp296 enhances the efficiency of reprogramming. In contrast, knockdown of Zfp296 in ESCs leads to the expression of differentiation markers. Finally, we demonstrated that expression of Zfp296 in ESCs inhibits, but does not block, differentiation into neural cells

    Regional remodeling strain and its association with myocardial apoptosis after myocardial infarction in an ovine model

    Get PDF
    ObjectiveProgressive left ventricular remodeling after myocardial infarction has been viewed as an important contributor to progressive heart failure. The objective of this study was to investigate the relationship between myocardial apoptosis and strain during progressive cardiac remodeling.MethodsBefore creation of an anterolateral left ventricular infarction by ligation of diagonal arteries, 16 sonomicrometry transducers were placed in the left ventricular free wall of 8 sheep to assess regional deformation in the infarct, adjacent, and normally perfused remote myocardial regions over 8 weeks' duration. Hemodynamic, echocardiographic and sonomicrometric data were collected before infarction and then 30 minutes and 2, 6, and 8 weeks after infarction. At the end of the study, regional myocardial tissues were collected for apoptotic signaling proteins.ResultsAt terminal study, an increase in left ventricular end-diastolic pressure of 8.1 ± 0.1 mm Hg, a decrease in ejection fraction from 54.19% ± 5.68% to 30.55% ± 2.72%, and an end-diastolic volume increase of 46.08 ± 5.02 mL as compared with the preinfarct values were observed. The fractional contraction at terminal study correlated with the relative abundance of apoptotic protein expressions: cytochrome c (r2 = 0.02, P < .05), mitochondrial Bax (r2 = 0.27, P < .05), caspase-3 (r2 = 0.31, P < .05), and poly (adenosine diphosphate–ribose) polymerase (r2 = 0.30, P < .05). These myocardial apoptotic activities also correlated with remodeling strain: cytochrome c (r2 = 0.02, P < .05), mitochondrial Bax (r2 = 0.28, P < .05), caspase-3 (r2 = 0.43, P < .05), and poly (adenosine diphosphate–ribose) polymerase (r2 = 0.37, P < .05).ConclusionIncrease in regional remodeling strain led to an increase in myocardial apoptosis and regional contractile dysfunction in heart failure

    Status of maturation of critical technologies and systems design: Breeding blanket

    Get PDF
    The scope of the EUFOfusion Work Package Breeding Blanket is to develop a blanket concept for the EU DEMO reactor; this includes the blanket segments inside the Vacuum Vessel and the related Tritium Extraction/Removal Systems. In the Pre-Concept Design (PCD) Phase, two concepts have been selected as candidates; a solid and a liquid breeder blanket cooled with helium and water, respectively. The design of these two blanket systems has been adapted to the DEMO plant design developed in the PCD Phase and performances assessed. A large R&D programme has been implemented with the scope to evaluate different technologies for these blankets; including the development of breeders, tritium extraction and cooling technologies, and the manufacturing of the blanket system. A major milestone in the subsequent Concept Design Phase is the final selection of the blanket concept for DEMO
    • …
    corecore