4,726 research outputs found

    Computer programs for calculating potential flow in propulsion system inlets

    Get PDF
    Calculational procedure evolved in process of designing inlets. Douglas axisymmetric potential flow program called EOD calculates incompressible potential flow about arbitrary bodies. Program SCIRCL generates input for EOD from inlet components. Program COMBYN takes basic solutions output by EOD and combines them into solutions of interest and applied compressibility correction

    Groundwater reinjection and heat dissipation: lessons from the operation of a large groundwater cooling system in Central London

    Get PDF
    The performance of a large open-loop groundwater cooling scheme in a shallow alluvial aquifer at a prominent public building in Central London has been monitored closely over its first 2 years of operation. The installed system provided cooling to the site continuously for a period of 9 months between June 2012 and April 2013. During this period, c. 131300 m3 of groundwater was abstracted from a single pumping well and recharged into a single injection borehole. The amount of heat rejected in this period amounts to c. 1.37 GWh. A programme of hydraulic testing was subsequently undertaken over a 3 month period between July and October 2013 to evaluate the performance of the injection borehole. The data indicate no significant change in injection performance between commissioning trials undertaken in 2010 and the most recent period of testing, as evidenced by comparison of injection pressures for given flow rates in 2010 and 2013. Continuous temperature monitoring of the abstracted water, the discharge and a number of observation wells demonstrates the evolution of a heat plume in the aquifer in response to heat rejection and subsequent dissipation of this heat during the 18 month planned cessation

    A simple proof of the Markoff conjecture for prime powers

    Full text link
    We give a simple and independent proof of the result of Jack Button and Paul Schmutz that the Markoff conjecture on the uniqueness of the Markoff triples (a,b,c), where a, b, and c are in increasing order, holds whenever cc is a prime power.Comment: 5 pages, no figure

    Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery†‡

    Get PDF
    Background Assessment of cardiac output (CO) by the FloTrac/Vigileo™ system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus™ system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo™ system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus™ system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance™ monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery. Methods Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland-Altman analysis was used to compare CCO, FCO, and PCO with ICO. Results Bland-Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period. Conclusion The performance of the FloTrac/Vigileo™ system, the PiCCOplus™, and the Vigilance™ CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surger

    Inertial measurement units for clinical movement analysis: reliability and concurrent validity

    Get PDF
    The aim of this study was to investigate the reliability and concurrent validity of a commercially available inertial-sensor-based motion capture system, Xsens MVN BIOMECH, during clinically relevant functional activities. A clinician with no prior experience of motion capture technologies and an experienced clinical movement scientist each assessed 26 healthy participants within each of two sessions using a camera-based motion capture system and the MVN BIOMECH system. Participants performed overground walking, squatting, and jumping. Sessions were separated by 4 ± 3 days. Reliability was evaluated using intraclass correlation coefficient and standard error of measurement, and validity was evaluated using the coefficient of multiple correlation and the linear fit method. Day-to-day reliability was generally fair-to-excellent in all three planes for hip, knee, and ankle joint angles in all three tasks. Within-day (between-rater) reliability was fair-to-excellent in all three planes during walking and squatting, and poor-to-high during jumping. Validity was excellent in the sagittal plane for hip, knee, and ankle joint angles in all three tasks and acceptable in frontal and transverse planes in squat and jump activity across joints. Our results suggest that the MVN BIOMECH system can be used by a clinician to quantify lower-limb joint angles in clinically relevant movements

    The ad-libitum alcohol 'taste test': secondary analyses of potential confounds and construct validity

    Get PDF
    RATIONALE: Motivation to drink alcohol can be measured in the laboratory using an ad-libitum 'taste test', in which participants rate the taste of alcoholic drinks whilst their intake is covertly monitored. Little is known about the construct validity of this paradigm. OBJECTIVE: The objective of this study was to investigate variables that may compromise the validity of this paradigm and its construct validity. METHODS: We re-analysed data from 12 studies from our laboratory that incorporated an ad-libitum taste test. We considered time of day and participants' awareness of the purpose of the taste test as potential confounding variables. We examined whether gender, typical alcohol consumption, subjective craving, scores on the Alcohol Use Disorders Identification Test and perceived pleasantness of the drinks predicted ad-libitum consumption (construct validity). RESULTS: We included 762 participants (462 female). Participant awareness and time of day were not related to ad-libitum alcohol consumption. Males drank significantly more alcohol than females (

    Models and metaphors: complexity theory and through-life management in the built environment

    Get PDF
    Complexity thinking may have both modelling and metaphorical applications in the through-life management of the built environment. These two distinct approaches are examined and compared. In the first instance, some of the sources of complexity in the design, construction and maintenance of the built environment are identified. The metaphorical use of complexity in management thinking and its application in the built environment are briefly examined. This is followed by an exploration of modelling techniques relevant to built environment concerns. Non-linear and complex mathematical techniques such as fuzzy logic, cellular automata and attractors, may be applicable to their analysis. Existing software tools are identified and examples of successful built environment applications of complexity modelling are given. Some issues that arise include the definition of phenomena in a mathematically usable way, the functionality of available software and the possibility of going beyond representational modelling. Further questions arising from the application of complexity thinking are discussed, including the possibilities for confusion that arise from the use of metaphor. The metaphor of a 'commentary machine' is suggested as a possible way forward and it is suggested that an appropriate linguistic analysis can in certain situations reduce perceived complexity
    corecore