110 research outputs found

    Replenishment of microRNA-188-5p restores the synaptic and cognitive deficits in 5XFAD Mouse Model of Alzheimer’s Disease

    Get PDF
    MicroRNAs have emerged as key factors in development, neurogenesis and synaptic functions in the central nervous system. In the present study, we investigated a pathophysiological significance of microRNA-188-5p (miR-188-5p) in Alzheimer’s disease (AD). We found that oligomeric Aβ(1-42) treatment diminished miR-188-5p expression in primary hippocampal neuron cultures and that miR-188-5p rescued the Aβ(1-42)-mediated synapse elimination and synaptic dysfunctions. Moreover, the impairments in cognitive function and synaptic transmission observed in 7-month-old five familial AD (5XFAD) transgenic mice, were ameliorated via viral-mediated expression of miR-188-5p. miR-188-5p expression was down-regulated in the brain tissues from AD patients and 5XFAD mice. The addition of miR-188-5p rescued the reduction in dendritic spine density in the primary hippocampal neurons treated with oligomeric Aβ(1-42) and cultured from 5XFAD mice. The reduction in the frequency of mEPSCs was also restored by addition of miR-188-5p. The impairments in basal fEPSPs and cognition observed in 7-month-old 5XFAD mice were ameliorated via the viral-mediated expression of miR-188-5p in the hippocampus. Furthermore, we found that miR-188 expression is CREB-dependent. Taken together, our results suggest that dysregulation of miR-188-5p expression contributes to the pathogenesis of AD by inducing synaptic dysfunction and cognitive deficits associated with Aβ-mediated pathophysiology in the disease

    Effect of Three-Dimensional Printed Personalized Moisture Chamber Spectacles on the Periocular Humidity

    Get PDF
    Purpose. To assess the effect of three-dimensional (3D) printed personalized moisture chamber spectacles (PMCS) on the periocular humidity. Methods. Facial computed tomography (CT) scanning was conducted on 10 normal subjects. PMCS was designed based on volume rendered CT images and produced using a 3D printer. Periocular humidity of PMCS and commercially available uniformed moisture chamber spectacles (UMCS) were measured for 30 minutes via microhydrometer. Results. The mean ambient humidity was 15.76±1.18%. The mean periocular humidity was 52.14±3.00% in PMCS and 37.67±8.97% in UMCS. The difference was significant (P<0.001). Additionally, PMCS always demonstrated lower humidity than dew points. Conclusion. PMCS made by 3D printer provides appropriate fitness for the semiclosed humid chamber. PMCS showed higher performance than UMCS. The wearing of PMCS would be an effective method to provide high enough periocular humidity in low humidity environment

    Pattern of Hepatitis A Incidence According to Area Characteristics Using National Health Insurance Data

    Get PDF
    Objectives: Over the past several years, the incidence of hepatitis A infection has been increasing rapidly in the young-adult population in Korea. We examined the effects of area-level socioeconomic status and environmental hygiene on the incidence of hepatitis A. Methods: This study is based on the registered national population of Korea and the national health insurance data from 2004 to 2008. A total of 73 459 individuals were confirmed to have had hepatitis A. The standardized incidences of hepatitis A in 232 districts adjusted for sex and age of people were calculated for each year, and the rate ratios of the incidence rates were estimated according to area-level socioeconomic status and environmental hygiene using multiple Poisson regression models. Results: The incidence rates of hepatitis A infection were 15.6 (per 100 000) in 2004, 19.0 (per 100 000) in 2005, 27.2 (per 100 000) in 2006, 25.1 (per 100 000) in 2007, and 61.7 (per 100 000) in 2008. The analysis of the area-level effects showed that residential areas of the less deprived than other regions, areas with higher levels of education, and heavily populated areas were significantly associated with increased risk. Conclusions: There is a very strong possibility that both area-level socioeconomic status and environmental hygiene play a role in increasing the risk of hepatitis A infection in Korea. Therefore, to reduce hepatitis A infection, we need a nationwide strategy that considers these area-level characteristics

    Comparison of the antibody responses to Plasmodium vivax and Plasmodium falciparum antigens in residents of Mandalay, Myanmar

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to investigate the profile of antibodies against several antigens of <it>Plasmodium vivax </it>and <it>Plasmodium falciparum </it>in Mandalay, Myanmar.</p> <p>Methods</p> <p>Malaria parasites were identified by microscopic examination. To test the antibodies against <it>P. vivax </it>and <it>P. falciparum </it>in sera, an indirect immunofluorescence antibody test (IFAT) was performed using asexual blood parasite antigens. An enzyme-linked immunosorbent assay (ELISA) was performed with circumsporozoite protein (CSP), Pvs25 and Pvs28 recombinant proteins of transmission-blocking vaccine candidates for <it>P. vivax</it>, and liver stage specific antigen-1 and -3 (PfLSA-1, PfLSA-3) for <it>P. falciparum</it>.</p> <p>Results</p> <p>Fourteen patients among 112 were found to be infected with <it>P. vivax </it>and 26 with <it>P. falciparum </it>by thick smear examination. Twenty-three patients were found to be infected with <it>P. vivax</it>, 19 with <it>P. falciparum </it>and five with both by thin smear examination. Blood samples were divided into two groups: Group I consisted of patients who were positive for infection by microscopic examination, and Group II consisted of those who showed symptoms, but were negative in microscopic examination. In <it>P. falciparum</it>, IgG against the blood stage antigen in Group I (80.8%) was higher than in Group II (70.0%). In <it>P. vivax</it>, IgG against the blood stage antigen in Group I (53.8%) was higher than in Group II (41.7%). However, the positivity rate of the PvCSP VK210 subtype in Group II (40.0%) was higher than in Group I (23.1%). Similarly for the PvCSP VK247 subtype, Group II (21.7%) was higher than that for Group I (9.6%). A similar pattern was observed in the ELISA using Pvs25 and Pvs28: positive rates of Group II were higher than those for Group I. However, those differences were not shown significant in statistics.</p> <p>Conclusions</p> <p>The positive rates for blood stage antigens of <it>P. falciparum </it>were higher in Group I than in Group II, but the positive rates for antigens of other stages (PfLSA-1 and -3) showed opposite results. Similar to <it>P. falciparum</it>, the positive rate of pre-blood stage (CSP VK210 and 247 subtype) and post-blood stage (Pvs25 and 28) antigens of <it>P. vivax </it>were higher in Group II than in Group I. Therefore, sero-diagnosis is not helpful to discriminate between malaria patients and symptomatic individuals during the epidemic season in Myanmar.</p

    Reliable Multivalued Conductance States in TaOx, Memristors through Oxygen Plasma-Assisted Electrode Deposition with in Situ-Biased Conductance State Transmission Electron Microscopy Analysis

    Get PDF
    Transition metal oxide-based memristors have widely been proposed for applications toward artificial synapses. In general, memristors have two or more electrically switchable stable resistance states that device researchers see as an analogue to the ion channels found in biological synapses. The mechanism behind resistive switching in metal oxides has been divided into electrochemical metallization models and valence change models. The stability of the resistance states in the memristor vary widely depending on: oxide material, electrode material, deposition conditions, film thickness, and programming conditions. So far, it has been extremely challenging to obtain reliable memristors with more than two stable multivalued states along with endurances greater than similar to 1000 cycles for each of those states. Using an oxygen plasma-assisted sputter deposition method of noble metal electrodes, we found that the metal-oxide interface could be deposited with substantially lower interface roughness observable at the nanometer scale. This markedly improved device reliability and function, allowing for a demonstration of memristors with four completely distinct levels from similar to 6 x 10(-6) to similar to 4 x 10(-8) S that were tested up to 10(4) cycles per level. Furthermore through a unique in situ transmission electron microscopy study, we were able to verify a redox reaction-type model to be dominant in our samples, leading to the higher degree of electrical state controllability. For solid-state synapse applications, the improvements to electrical properties will lead to simple device structures, with an overall power and area reduction of at least 1000 times when compared to SRAM.11Ysciescopu

    Tailored Graphene Micropatterns by Wafer-Scale Direct Transfer for Flexible Chemical Sensor Platform

    Get PDF
    2D materials, such as graphene, exhibit great potential as functional materials for numerous novel applications due to their excellent properties. The grafting of conventional micropatterning techniques on new types of electronic devices is required to fully utilize the unique nature of graphene. However, the conventional lithography and polymer-supported transfer methods often induce the contamination and damage of the graphene surface due to polymer residues and harsh wet-transfer conditions. Herein, a novel strategy to obtain micropatterned graphene on polymer substrates using a direct curing process is demonstrated. Employing this method, entirely flexible, transparent, well-defined self-activated graphene sensor arrays, capable of gas discrimination without external heating, are fabricated on 4 in. wafer-scale substrates. Finite element method simulations show the potential of this patterning technique to maximize the performance of the sensor devices when the active channels of the 2D material are suspended and nanoscaled. This study contributes considerably to the development of flexible functional electronic devices based on 2D materials.

    Renal Toxicity Evaluation and Comparison Between Visipaque (Iodixanol) and Hexabrix (Ioxaglate) in Patients With Renal Insufficiency Undergoing Coronary Angiography The RECOVER Study: A Randomized Controlled Trial

    Get PDF
    ObjectivesThis study sought to compare the nephrotoxicity of iodixanol and ioxaglate in patients with renal impairment undergoing coronary angiography.BackgroundIodixanol, a nonionic, dimeric, iso-osmolar contrast medium (IOCM), may be less nephrotoxic than low-osmolar contrast media (LOCM) in high-risk patients.MethodsIn a prospective, randomized trial in 300 adults with creatinine clearance (CrCl) ≤60 ml/min, patients received either iodixanol or ioxaglate and underwent coronary angiography with or without percutaneous coronary intervention. The primary end point was the incidence of contrast-induced nephropathy (CIN) (an increase in serum creatinine [SCr] ≥25% or ≥0.5 mg/dl [≥44.2 μmol/l]). The incidence of CIN in patients with severe renal impairment at baseline (CrCl <30 ml/min) or diabetes and in those receiving large doses (≥140 ml) of contrast medium was also determined.ResultsThe incidence of CIN was significantly lower with iodixanol (7.9%) than with ioxaglate (17.0%; p = 0.021), corresponding to an odds ratio (OR) of CIN of 0.415 (95% confidence interval [CI] 0.194 to 0.889) for iodixanol. The incidence of CIN was also significantly lower with iodixanol in patients with severe renal impairment (p = 0.023) or concomitant diabetes (p = 0.041), or in patients given ≥140 ml of contrast media (p = 0.038). Multivariate analysis identified use of ioxaglate (OR 2.65, 95% CI 1.11 to 6.33, p = 0.028), baseline SCr, mg/dl (OR 2.0, 95% CI 1.04 to 3.85, p = 0.038), and left ventricular ejection fraction, % (OR 0.97, 95% CI 0.94 to 0.99, p = 0.019) as independent risk factors for CIN.ConclusionsThe IOCM iodixanol was significantly less nephrotoxic than ioxaglate, an ionic, dimeric LOCM. (The RECOVER Trial; http://clinicaltrials.gov; NCT00247325

    High-performance and scalable metal-chalcogenide semiconductors and devices via chalco-gel routes

    Get PDF
    We report a general strategy for obtaining high-quality, large-areametal-chalcogenide semiconductor films from precursors combining chelated metal salts with chalcoureas or chalcoamides. Using conventional organic solvents, such precursors enable the expeditious formation of chalco-gels,which are easily transformed into the corresponding highperformance metal-chalcogenide thin films with large, uniform areas. Diverse metal chalcogenides and their alloys (MQx: M = Zn, Cd, In, Sb, Pb; Q = S, Se, Te) are successfully synthesized at relatively low processing temperatures (&amp;lt;400°C). The versatility of this scalable route is demonstrated by the fabrication of large-area thin-film transistors (TFTs), optoelectronic devices, and integrated circuits on a 4-inch Si wafer and 2.5-inch borosilicate glass substrates in ambient air using CdS, CdSe, and In2Se3 active layers. The CdSe TFTs exhibit a maximum field-effect mobility greater than 300 cm2 V-1 s-1 with an on/off current ratio of &amp;gt;107 and good operational stability (threshold voltage shift &amp;lt; 0.5 V at a positive gate bias stress of 10 ks). In addition,metal chalcogenide-based phototransistors with a photodetectivity of &amp;gt;1013 Jones and seven-stage ring oscillators operating at a speed of ∼2.6 MHz (propagation delay of &amp;lt; 27 ns per stage) are demonstrated. © 2018 The Authors.1

    Endovascular Management of Iliofemoral Deep Venous Thrombosis due to Iliac Vein Compression Syndrome in Patients with Protein C and/or S Deficiency

    Get PDF
    The purpose of this study was to evaluate the early outcome of endovascular management in patients with iliofemoral deep venous thrombosis (DVT) due to iliac vein compression syndrome (IVCS) and protein C and/or S deficiency. Between September 2000 and January 2003, catheter-directed thrombolysis was performed in 11 patients with a diagnosis of acute iliofemoral DVT: 7 with protein C and/or S deficiency and 4 without protein C and/or S deficiency. After thrombolysis, the diagnosis of IVCS was confirmed in 6 patients: 4 with protein C and/or S deficiency and 2 without protein C and/or S deficiency. Further intervention consisted of angioplasty and stent placement was performed. Four patients with IVCS and protein C and/or S deficiency were included in this study. The immediate technical and clinical success rates were 100% in all 4 patients. There were no complications or clinically detectable pulmonary emboli. This initial experience suggests that endovascular management of iliofemoral DVT due to IVCS in patients with protein C and/or S deficiency is safe and effective

    Non-specific Defensive Factors of the Pacific Oyster Crassostrea gigas against Infection with Marteilioides chungmuensis: A Flow-Cytometric Study

    Get PDF
    In order to assess changes in the activity of immunecompetency present in Crassostrea gigas infected with Marteilioides chungmuensis (Protozoa), the total hemocyte counts (THC), hemocyte populations, hemocyte viability, and phagocytosis rate were measured in oysters using flow cytometry. THC were increased significantly in oysters infected with M. chungmuensis relative to the healthy appearing oysters (HAO) (P<0.05). Among the total hemocyte composition, granulocyte levels were significantly increased in infected oysters as compared with HAO (P<0.05). In addition, the hyalinocyte was reduced significantly (P<0.05). The hemocyte viability did not differ between infected oysters and HAO. However, the phagocytosis rate was significantly higher in infected oysters relative to HAO (P<0.05). The measurement of alterations in the activity of immunecompetency in oysters, which was conducted via flow cytometry in this study, might be a useful biomarker of the defense system for evaluating the effects of ovarian parasites of C. gigas
    corecore