98 research outputs found

    Dizajn maske za lice s UVC-LED zračenjem i njezina djelotvornost protiv uobičajenih klica

    Get PDF
    During the Covid-19 pandemic, one of the best means of personal protection was using face masks. In this context, the World Health Organization has declared the attempts to produce masks inactivating airborne virus species a welcome initiative. This preliminary study aimed to prove that airborne germs passing through a mask filter cartridge can be destroyed by the rays emitted from UVC LEDs placed in such cartridge. We therefore designed such a face mask and tested the efficiency of UVC LEDs placed in its cartridge against common contaminants, gram-positive Staphylococcus aureus, gram-negative Pseudomonas aeruginosa, and the influenza A/Puerto Rico/8/1934 virus because of its similarity with SARS CoV-2. Eight UVC LEDs with a total power of 75 mW provided sufficient germicidal effect for all three germs. In terms of safety, ozone production released during UVC LED emission was negligible. Our findings are promising, as they show that well-designed UVC-based face masks can be effective against airborne germs, but further research on a greater sample may help us learn more and optimise such face masks.Tijekom pandemije Covida-19 jedan od najboljih oblika osobne zaštite bilo je nošenje maski za lice. U tom je smislu Svjetska zdravstvena organizacija pozdravila pokušaje izrade maski koje ubijaju virusne vrste koje se prenose zrakom. Cilj je ovoga preliminarnog istraživanja bio dokazati da se zrakom nošene klice koje prolaze kroz filtarske uloške mogu uništiti zračenjem UVC ledica smještenih u takve uloške. Stoga smo osmislili masku za lice s tom namjenom i iskušali djelotvornost UVC ledica protiv uobičajenih izvora zaraza: gram-pozitivnoga Staphylococcus aureus, gram-negativnoga Pseudomonas aeruginosa i virusa influence A/Puerto Rico/8/1934 zbog njegove sličnosti s virusom SARS CoV-2. Osam UVC ledica ukupne snage 75 mW iskazale su dovoljan germicidni učinak protiv svih triju klica. U smislu sigurnosti primjene, ozon proizveden tijekom UVC-LED zračenja pokazao se zanemarivim. Naši su rezultati obećavajući jer pokazuju da dobro osmišljene maske za lice s UVC zračenjem mogu biti djelotvorne protiv zrakom nošenih klica, ali će tek daljnja istraživanja na većem uzorku pomoći da doznamo više i usavršimo takve maske za lice

    Problems encountered in conventional HIV 1/2 Algorithms: lack of necessity for immunoblot assays to confirm repeated ELISA reactive results

    Get PDF
    Background: The use of conventional (serologically based) HIV 1/2 diagnostic algorithms has become controversial in recent years.Objectives: Sera from patients who underwent verification tests were evaluated because repeated ELISA-reactive results demonstrated a HIV1+HIV2 positive band pattern.Methods: The line immunoassay (LIA) test was used for repeated HIV enzyme immunoassays (EIA)-reactive sera in patients at three centers. The Bio-Rad Geenius™ HIV 1/2 and the HIV-1 RNA tests were used. HIV-1 and RNA HIV-2 were investigated using PCR.Results: LIA was used to evaluate 3,224 out of 10,591 samples with repeated ELISA reactivity (30%). We found that 32 (1%) of the sera, along with HIV1 bands and HIV2 gp36 bands, were positive. Only 28 of the 32 verified serum samples with gp36 bands were repeated, and no gp36 band positivity was detected using the Bio-Rad Geenius™ HIV-1/2 confirmatory assay in these serum samples. The HIV-2 proviral DNAs were also negative. Therefore, we excluded the possibility of HIV1+2 co-infection. All samples from the 32 patients were positive for HIV-1 RNA.Conclusion: Our findings highlight the need to exclude confirmatory tests like the LIA test from the current diagnostic HIV algorithm and replace it with rapid HIV-1 and HIV-2 confirmatory immunochromotographic tests.Keywords: HIV, AIDS, HIV-2

    A pan-resistant Myroides odoratimimus catheter-related bacteremia in a COVID-19 patient and review of the literature

    Get PDF
    Myroides spp. are opportunistic environmental Gram-negative bacteria. These affect mostly immunocompromised hosts and generally lead to soft tissue, and urinary tract infections. Bacteremia most commonly develop secondary to soft tissue or catheter related infections and may lead rarely to mortality. Myroides spp. are generally suscetible to fluoroquinolones, piperacillin/tazobactam, trimethoprim/sulfamethoxazole, carbapenems or tetracyclines however, pan-resistant isolates and multiple resistance genes have been reported in clinical isolates of Myroides spp. We report a pan-resistant Myroides odoratimimus bacteremia in a patient with severe COVID-19 ending with fatality and in this context a review of reported Myroides bacteremias are also described. In this study, a 64-year old male patient with history of coronary artery bypass was admitted to ICU with severe COVID-19 pneumonia accompanied by pneumomediastinum and pneumopericardium. Continous renal replacement therapy and extracorporeal membraneous-oxygenation were initiated due to acute renal failure and persistent hypercarbia/hypoxia, respectively. Within four weeks of hospitalization various episodes of bacteremia developed and multiple antibiotics were used. On the 5th week of follow-up, acute phase reactants increased and empirical broad spectrum antibiotics were initiated. Blood culture revealed Gram-negative rods. The patient became hypotensive and despite maximum medical care he was lost due to cardiac arrest. M. odoratimimus was identified by MALDI-TOF and the bacterium was pan-resistant. According to Center for Genomic Epidemiology results the strain was identified as M. odoratimimus PR63039 and the genome analysis revealed antibiotic resistance genes associated with resistance to beta-lactams (bla(OXA-347), bla(MUS-1), bla(EBR-1)), tetracyclines (tetX), sulfonamides (sul2), macrolides (ereD), (ermF)

    Problems encountered in conventional HIV 1/2 Algorithms: lack of necessity for immunoblot assays to confirm repeated ELISA reactive results

    Get PDF
    Background: The use of conventional (serologically based) HIV 1/2 diagnostic algorithms has become controversial in recent years. Objectives: Sera from patients who underwent verification tests were evaluated because repeated ELISA-reactive results demonstrated a HIV1+HIV2 positive band pattern. Methods: The line immunoassay (LIA) test was used for repeated HIV enzyme immunoassays (EIA)-reactive sera in patients at three centers. The Bio-Rad Geenius\u2122 HIV 1/2 and the HIV-1 RNA tests were used. HIV-1 and RNA HIV-2 were investigated using PCR. Results: LIA was used to evaluate 3,224 out of 10,591 samples with repeated ELISA reactivity (30%). We found that 32 (1%) of the sera, along with HIV1 bands and HIV2 gp36 bands, were positive. Only 28 of the 32 verified serum samples with gp36 bands were repeated, and no gp36 band positivity was detected using the Bio-Rad Geenius\u2122 HIV-1/2 confirmatory assay in these serum samples. The HIV-2 proviral DNAs were also negative. Therefore, we excluded the possibility of HIV1+2 co-infection. All samples from the 32 patients were positive for HIV-1 RNA. Conclusion: Our findings highlight the need to exclude confirmatory tests like the LIA test from the current diagnostic HIV algorithm and replace it with rapid HIV-1 and HIV-2 confirmatory immunochromotographic tests

    The effect of CD14 and TLR4 gene polimorphisms on asthma phenotypes in adult Turkish asthma patients: a genetic study

    No full text
    Background: Endotoxins stimulate T helper 1 cell maturation and send a negative signal to T helper 2 polarisation. This causes a decrease IgE levels and prevents atopy (Hygiene hypothesis). It is shown that this response is under genetic control by polymorphisms in CD14 and TLR4 genes in some researchs. We aimed to investigate the effects of genetic variants of CD14 (-) and TLR4 (Asp299Gly, Thr399Ile) genes on asthma phenotypes in adults with asthma
    corecore