24 research outputs found

    Malus law – interferometric interpretation

    No full text
    The aim of the present work is the description of a novel interferometric approach to the commonly known Malus law. In this approach we have described an analyzer as an element realizing the interference of two waves being the components of the linearly polarized wave emerging from the polarizer. We have proposed a decomposition of the polarization state of the light incident on the analyzer into two different bases. The choice of a first base – linearly polarized – allows interpreting Malus law as an interference of two linearly polarized waves with the same polarization state, different amplitudes and the same phases. The second decomposition, based on circularly polarized vectors, leads to the description in which Malus law can be interpreted as an interference of two waves with the same amplitudes but different phases. This allows the introduction of the concept of the geometric phase into Malus law as well as the visualization of this phase on the Poincaré sphere

    Wpływ modyfikacji termicznej w oleju na zawartość substancji ekstrakcyjnych oraz polisacharydów w drewnie dębu (Quercus sp. L)

    No full text

    Detekcja porowatości z wykorzystaniem technicznej tomografii komputerowej

    No full text
    Industrial computed tomography (CT) supports quality inspection of manufactured technical objects and product development thanks to its possibility of non-destructive detection of porosity. Application of computed tomography to porosity detection permits not only qualitative evaluation of internal structure of objects, but also quantitative evaluation of material porosity with representation of three-dimensional shape of pores and their spatial distribution. The paper presents a brief characteristic of the factors influencing effectiveness of porosity detection by CT. A technical example illustrates influence of the applied magnification on the possibility to detect porosity and represent shapes of pores. Next, the results of porosity evaluation obtained by CT and by standard microscopic examinations are compared. It was demonstrated that result of porosity detection is influenced by magnification and resolution of CT measurements.Techniczna tomografia komputerowa CT (ang. Computed Tomography) wspomaga kontrolę jakości wytwarzanych obiektów technicznych i rozwój produktu dzięki możliwości nieniszczącej detekcji porowatości. Wykorzystanie tomografii komputerowej w defektoskopii pozwala nie tylko na jakościową ocenę struktury wewnętrznej obiektów, ale i na ilościową ocenę porowatości ich materiału z odwzorowaniem trójwymiarowego kształtu porów i ich rozkładu przestrzennego. W pracy przedstawiono krótką charakterystykę czynników wpływających na skuteczność detekcji porowatości z wykorzystaniem metody CT. Na przykładzie obiektu technicznego przedstawiono wpływ zastosowanego powiększenia na możliwości detekcji porowatości i odwzorowania kształtu porów. Następnie porównano wyniki porowatości uzyskanej z wykorzystaniem metody CT i standardowych badań mikroskopowych. Wykazano wpływ powiększenia i rozdzielczości pomiaru na możliwość detekcji porów z wykorzystaniem metody CT
    corecore