12 research outputs found

    Serum microRNA-1233 is a specific biomarker for diagnosing acute pulmonary embolism

    Get PDF
    Publisher Copyright: © 2016 The Author(s). Copyright: Copyright 2017 Elsevier B.V., All rights reserved.Background: Circulating microRNAs (miRNAs) emerge as novel biomarkers in cardiovascular diseases. Diagnosing acute pulmonary embolism (PE) remains challenging due to a diverse clinical presentation and the lack of specific biomarkers. Here we evaluate serum miRNAs as potential biomarkers in acute PE. Methods: We enrolled 30 patients with acute, CT (computed tomography)-angiographically confirmed central PE and collected serum samples on the day of emergency room admission (1st day) and from 22 of these patients 9 months thereafter. For comparison, we examined serum samples from patients with acute non ST-segment elevation myocardial infarction (NSTEMI, n = 30) and healthy individuals (n = 12). Results: We randomly selected 16 out of 30 PE patients and screened sera from the acute (1st day) and chronic stages (9 months) for 754 miRNAs using microarrays and found 37 miRNAs to be differentially regulated. Across all miRNAs, miRNA-1233 displayed the highest fold change (FC) from acute to chronic stage (log2FC 11.5, p < 0.004). We validated miRNA-1233 by real-time quantitative polymerase chain reaction (RT-qPCR). In acute PE (1st day) we found elevated levels of miRNA-1233 in comparison to NSTEMI (log2FC 5.7, p < 0.0001) and healthy controls (log2FC 7.7, p < 0.0001). miRNA-1233 differentiated acute PE from NSTEMI patients and healthy individuals with 90 and 90 % sensitivity, and 100 and 92 % specificity [area under the curve (AUC) 0.95, p < 0.001 and 0.91, p < 0.001], respectively. Conclusions: This is the first report that identifies a miRNA that allows distinguishing acute PE from acute NSTEMI and healthy individuals with high specificity and sensitivity.publishersversionPeer reviewe

    Drug eluting balloons for the treatment of coronary artery disease: What can we expect?

    No full text
    Drug-eluting balloons (DEBs) represent an enhancement of the therapeutic repertoire for the interventional cardiologist. The therapeutic concept of DEBs is promising, notably on the basis of initial studies in patients with diffuse in-stent restenosis (ISR). At present, however, a number of questions regarding long-term efficacy and safety remain, specifically in indications other than diffuse ISR. The results of the evaluation of different substances, balloon systems and clinical indications will determine the long-term success of DEBs

    Hospital acquired pneumonia with high-risk bacteria is associated with increased pulmonary matrix metalloproteinase activity

    No full text
    Abstract Background Neutrophil products like matrix metalloproteinases (MMP), involved in bacterial defence mechanisms, possibly induce lung damage and are elevated locally during hospital- acquired pneumonia (HAP). In HAP the virulence of bacterial species is known to be different. The aim of this study was to investigate the influence of high-risk bacteria like S. aureus and pseudomonas species on pulmonary MMPconcentration in human pneumonia. Methods In 37 patients with HAP and 16 controls, MMP-8, MMP-9 and tissue inhibitors of MMP (TIMP) were analysed by ELISA and MMP-9 activity using zymography in bronchoalveolar lavage (BAL). Results MMP-9 activity in mini-BAL was increased in HAP patients versus controls (149 ± 41 vs. 34 ± 11, p Conclusion Pulmonary MMP concentrations and MMP activity are elevated in patients with HAP. This effect is most pronounced in patients with high-risk bacteria. Artificial ventilation may play an additional role in protease activation.</p

    Automatic analysis of ST segment changes during Holter recording.

    No full text
    <p>The upper image depicts the deviation of the J +80 measurement point (80 ms after J point) within a 10 minute period (pt. no. 7). At 20 h 26 min 50 s an ischemic episode of 2 min 45s duration was detected. J +80 measurement point deviation >100 µV is marked in black. The lower image depicts the corresponding heart rate (HR).</p

    Typical left ventricular apical ballooning.

    No full text
    <p>Left ventriculography in right anterior oblique projection during diastole (1a) and systole (1b) demonstrating akinesia of the apical and midventricular segments. Selective coronary angiograms of the left (1c) and right coronary artery (1d) excluding obstructive coronary artery disease.</p

    ST segment detail.

    No full text
    <p>Recordings show baseline ST depression in both recording channels (left tracing). During an automatically detected ischemic event at 20 h 26 min 59s an additional transient ST depression occurs in channel 1 (arrow, right tracing).</p

    Stent thrombosis and major clinical events at 3 years after zotarolimus-eluting or sirolimus-eluting coronary stent implantation: a randomised, multicentre, open-label, controlled trial

    No full text
    Item does not contain fulltextBACKGROUND: We sought to compare the long-term safety of two devices with different antiproliferative properties: the Endeavor zotarolimus-eluting stent (E-ZES; Medtronic, Inc) and the Cypher sirolimus-eluting stent (C-SES; Cordis, Johnson & Johnson) in a broad group of patients and lesions. METHODS: Between May 21, 2007 and Dec 22, 2008, we recruited 8791 patients from 36 recruiting countries to participate in this open-label, multicentre, randomised, superiority trial. Eligible patients were those aged 18 years or older undergoing elective, unplanned, or emergency procedures in native coronary arteries. Patients were randomly assigned to either receive E-ZES and C-SES (ratio 1:1). Randomisation was stratified per centre with varying block sizes of four, six, or eight patients, and concealed with a central telephone-based or web-based allocation service. The primary outcome was definite or probable stent thrombosis at 3 years and was analysed by intention to treat. Patients and investigators were aware of treatment assignment. This trial is registered with ClinicalTrials.gov, number NCT00476957. FINDINGS: PROTECT randomised 8791 patients, of whom 8709 provided consent to participate and were eligible: 4357 were allocated to the E-ZES group and 4352 patients to the C-SES group. At 3 years, rates of definite or probable stent thrombosis did not differ between groups (1.4% for E-ZES [predicted: 1.5%] vs 1.8% [predicted: 2.5%] for C-SES; hazard ratio [HR] 0.81, 95% CI 0.58-1.14, p=0.22). Dual antiplatelet therapy was used in 8402 (96%) patients at discharge, 7456 (88%) at 1 year, 3041 (37%) at 2 years, and 2364 (30%) at 3 years. INTERPRETATION: No evidence of superiority of E-ZES compared with C-SES in definite or probable stent thrombosis rates was noted at 3 years. Time analysis suggests a difference in definite or probable stent thrombosis between groups is emerging over time, and a longer follow-up is therefore needed given the clinical relevance of stent thrombosis. FUNDING: Medtronic, Inc