146 research outputs found

    Theory and validation of access flow measurement by dilution technique during hemodialysis

    Get PDF
    Access blood flow is currently measured by color-coded duplex sonography which has the ability to select groups of patients with higher risk of access failure [1]. There are also reports of operator errors [2] and of precision limitations arising from random uncertainties in the measurement of vessel diameter and Doppler angle [3]. Color-coded duplex sonography is an expensive technique and measurements are made only rarely. The onset of reduced flow can therefore be missed.We recently reported a modification of the indicator dilution method for measuring access flow during hemodialysis [4] and the initial clinical use of this method [5]. This paper presents the theory and bench validation for this new access flow measurement technique

    In-Network Outlier Detection in Wireless Sensor Networks

    Full text link
    To address the problem of unsupervised outlier detection in wireless sensor networks, we develop an approach that (1) is flexible with respect to the outlier definition, (2) computes the result in-network to reduce both bandwidth and energy usage,(3) only uses single hop communication thus permitting very simple node failure detection and message reliability assurance mechanisms (e.g., carrier-sense), and (4) seamlessly accommodates dynamic updates to data. We examine performance using simulation with real sensor data streams. Our results demonstrate that our approach is accurate and imposes a reasonable communication load and level of power consumption.Comment: Extended version of a paper appearing in the Int'l Conference on Distributed Computing Systems 200

    Effect of Time on Sensitivity and Specificity of Access Flow in Predicting Thrombosis

    Full text link
    Dialysis access monitoring may help decrease thrombosis-related morbidity. We investigated the effect of time elapsed since an access flow measurement on test accuracy of a novel flow monitoring method called variable flow (VF) Doppler. A retrospective review was conducted in 36 patients with prosthetic grafts for vascular access using access thrombosis as the clinical endpoint. Receiver operator characteristic (ROC) curves and test sensitivity and specificity were determined for various follow-up time intervals. ROC analysis showed increasing test discrimination for shorter time intervals. Sensitivity and specificity for a commonly used surveillance threshold (600 ml/min) showed specificity that was little changed (88–93%) from follow-up time intervals of 15 days to 6 months. However, sensitivity was low (21%) at 6 months, increased to 50% at 2 months, 67% at 1 month, and 100% at 15 days (a single event). Low access blood flow using VF Doppler predicts near-term thrombosis. These data further imply that the discriminative value of access flow monitoring appears to be highly dependent on time from the flow measurement, improving with shorter time intervals from the measurement.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/74923/1/j.1525-139X.2003.16107.x.pd

    Quantification of recirculation as an adjuvant to transthoracic echocardiography for optimization of dual-lumen extracorporeal life support

    Get PDF
    Proper cannula positioning in single site veno-venous extracorporeal life support (vv-ELS) is cumbersome and necessitates image guidance to obtain a safe and stable position within the heart and the caval veins. Importantly, image-guided cannula positioning alone is not sufficient, as possible recirculation cannot be quantified. We present an ultrasound dilution technique allowing quantification of recirculation for optimizing vv-ELS. We suggest quantification of recirculation in addition to image guidance to provide optimal vv-ELS

    Early Vascular Access Blood Flow as a Predictor of Long-term Vascular Access Patency in Incident Hemodialysis Patients

    Get PDF
    The long-term clinical benefits of vascular access blood flow (VABF) measurements in hemodialysis (HD) patients have been controversial. We evaluated whether early VABF may predict long-term vascular access (VA) patency in incident HD patients. We enrolled 57 patients, of whom 27 were starting HD with arteriovenous fistulas (AVFs) and 30 with arteriovenous grafts (AVGs). The patients' VABF was measured monthly with the ultrasound dilution technique over the course of the first six months after the VA operation. During the 20.4-month observational period, a total of 40 VA events in 23 patients were documented. The new VA events included 13 cases of stenosis and 10 thrombotic events. The lowest quartile of average early VABF was related to the new VA events. After adjusting for covariates such as gender, age, hypertension, diabetes, VA type, hemoglobin levels, body mass index, parathyroid hormone, and calcium-phosphorus product levels, the hazard ratio of VABF (defined as <853 mL/min in AVF or <830 mL/min in AVG) to incident VA was 3.077 (95% confidence interval, 1.127-8.395; P=0.028). There were no significant relationships between early VABF parameters and VA thrombosis. It is concluded that early VABF may predict long-term VA patency, particularly VA stenosis

    Arterial line pressure control enhanced extracorporeal blood flow prescription in hemodialysis patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In hemodialysis, extracorporeal blood flow (Qb) recommendation is 300–500 mL/min. To achieve the best Qb, we based our prescription on dynamic arterial line pressure (DALP).</p> <p>Methods</p> <p>This prospective study included 72 patients with catheter Group 1 (G1), 1877 treatments and 35 arterio-venous (AV) fistulae Group 2 (G2), 1868 treatments. The dialysis staff was trained to prescribe Qb sufficient to obtain DALP between -200 to -250 mmHg. We measured ionic clearance (IK: mL/min), access recirculation, DALP (mmHg) and Qb (mL/min). Six prescription zones were identified: from an optimal A zone (Qb > 400, DALP -200 to -250) to zones with lower Qb E (Qb < 300, DALP -200 to -250) and F (Qb < 300, DALP > -199).</p> <p>Results</p> <p>Treatments distribution in A was 695 (37%) in G1 vs. 704 (37.7%) in G2 (<it>P </it>= 0.7). In B 150 (8%) in G1 vs. 458 (24.5%) in G2 (<it>P </it>< 0.0001). Recirculation in A was 10.0% (Inter quartile rank, IQR 6.5, 14.2) in G1 vs. 9.8% (IQR 7.5, 14.1) in G2 (<it>P </it>= 0.62). IK in A was 214 ± 34 (G1) vs. 213 ± 35 (G2) (<it>P </it>= 0.65). IK Anova between G2 zones was: A vs. C and D (<it>P </it>< 0.000001). Staff prescription adherence was 81.3% (G1) vs. 84.1% (G2) (<it>P </it>= 0.02).</p> <p>Conclusion</p> <p>In conclusion, an optimal Qb can de prescribed with DALP of -200 mmHg. Staff adherence to DLAP treatment prescription could be reached up to 81.3% in catheters and 84.1% in AV fistulae.</p

    Human Papillomavirus & Recurrent Respiratory Papillomatosis

    No full text
    This review of literature contains information regarding the human papillomavirus in general - structure, diseases, diagnosis and treatment - and information regarding recurrent respiratory papillomatosis in particular, such as disease mechanism, etiology, diagnostic approach, current and future notions of therapy and prognosis.egységes, osztatlanåltalånos orvosango
    • 

    corecore