128 research outputs found
The barrel DIRC of PANDA
Cooled antiproton beams of unprecedented intensities in the momentum range of 1.5-15 GeV/c will be used for the PANDA experiment at FAIR to perform high precision experiments in the charmed quark sector. The PANDA detector will investigate antiproton annihilations with beams in the momentum range of 1.5 GeV/c to 15 GeV/c on a fixed target. An almost 4π acceptance double spectrometer is divided in a forward spectrometer and a target spectrometer. The charged particle identification in the latter is performed by ring imaging Cherenkov counters employing the DIRC principle
The barrel DIRC of PANDA
Cooled antiproton beams of unprecedented intensities in the momentum range of 1.5-15 GeV/c will be used for the PANDA experiment at FAIR to perform high precision experiments in the charmed quark sector. The PANDA detector will investigate antiproton annihilations with beams in the momentum range of 1.5 GeV/c to 15 GeV/c on a fixed target. An almost 4π acceptance double spectrometer is divided in a forward spectrometer and a target spectrometer. The charged particle identification in the latter is performed by ring imaging Cherenkov counters employing the DIRC principle
Status of the PANDA barrel DIRC
The PANDA experiment at the future Facility for Antiproton and Ion Research in Europe GmbH (FAIR) at GSI, Darmstadt will study fundamental questions of hadron physics and QCD using high-intensity cooled antiproton beams with momenta between 1.5 and 15 GeV/c. Hadronic PID in the barrel region of the PANDA detector will be provided by a DIRC (Detection of Internally Reflected Cherenkov light) counter. The design is based on the successful BABAR DIRC with several key improvements, such as fast photon timing and a compact imaging region. Detailed Monte Carlo simulation studies were performed for DIRC designs based on narrow bars or wide plates with a variety of focusing solutions. The performance of each design was characterized in terms of photon yield and single photon Cherenkov angle resolution and a maximum likelihood approach was used to determine the π/K separation. Selected design options were implemented in prototypes and tested with hadronic particle beams at GSI and CERN. This article describes the status of the design and R&D for the PANDA Barrel DIRC detector, with a focus on the performance of different DIRC designs in simulation and particle beams
The barrel DIRC of PANDA
Cooled antiproton beams of unprecedented intensities in the momentum range of 1.5-15 GeV/c will be used for the PANDA experiment at FAIR to perform high precision experiments in the charmed quark sector. The PANDA detector will investigate antiproton annihilations with beams in the momentum range of 1.5 GeV/c to 15 GeV/c on a fixed target. An almost 4π acceptance double spectrometer is divided in a forward spectrometer and a target spectrometer. The charged particle identification in the latter is performed by ring imaging Cherenkov counters employing the DIRC principle
Dependence of aptamer activity on opposed terminal extensions: improvement of light-regulation efficiency
Aptamers that can be regulated with light allow precise control of protein activity in space and time and hence of biological function in general. In a previous study, we showed that the activity of the thrombin-binding aptamer HD1 can be turned off by irradiation using a light activatable ‘caged’ intramolecular antisense-domain. However, the activity of the presented aptamer in its ON state was only mediocre. Here we studied the nature of this loss in activity in detail and found that switching from 5′- to 3′-extensions affords aptamers that are even more potent than the unmodified HD1. In particular we arrived at derivatives that are now more active than the aptamer NU172 that is currently in phase 2 clinical trials as an anticoagulant. As a result, we present light-regulatable aptamers with a superior activity in their ON state and an almost digital ON/OFF behavior upon irradiation
Dependence of aptamer activity on opposed terminal extensions: improvement of light-regulation efficiency
Aptamers that can be regulated with light allow precise control of protein activity in space and time and hence of biological function in general. In a previous study, we showed that the activity of the thrombin-binding aptamer HD1 can be turned off by irradiation using a light activatable ‘caged’ intramolecular antisense-domain. However, the activity of the presented aptamer in its ON state was only mediocre. Here we studied the nature of this loss in activity in detail and found that switching from 5′- to 3′-extensions affords aptamers that are even more potent than the unmodified HD1. In particular we arrived at derivatives that are now more active than the aptamer NU172 that is currently in phase 2 clinical trials as an anticoagulant. As a result, we present light-regulatable aptamers with a superior activity in their ON state and an almost digital ON/OFF behavior upon irradiation
Using Automated Glycan Assembly (AGA) for the Practical Synthesis of Heparan Sulfate Oligosaccharide Precursors
Herein we report synthesis of complex heparan sulfate oligosaccharide precursors by automated glycan assembly using disaccharide donor building blocks. Rapid access to a hexasaccharide was achieved through iterative solid phase glycosylations on a photolabile resin using Glyconeer™, an automated oligosaccharide synthesiser, followed by photochemical cleavage and glycan purification using simple flash column chromatography
The DIRC detectors at the PANDA experiment
PANDA is an experiment at the new FAIR facility at GSI and will, among other physics goals,
perform charmonium spectroscopy and search for gluonic excitations using high luminosity antiproton beams up to 15 GeV/c. A high performance particle identification system applying DIRC
detectors will allow pion/kaon separation up to 4 GeV/c. A Barrel DIRC with fused silica radiator bars or plates will surround the target at a radial distance of 48 cm and will cover a polar
angle range of 22 to 140 degrees; a novel Endcap Disk DIRC built of a segmented fused silica
disk of 210 cm diameter will be installed in the forward region to cover the polar angles from
5 to 22 degrees. The design of the optics and the readout of both DIRCs will be presented in
this paper. Different prototypes were tested in particle beams. The performance of the latest prototypes, which are close to the final DIRC design, are discussed and compared to the PANDA
requirements
New developments of the PANDA Disc DIRC detector
The DIRC principle (Detection of Internally Reflected Cherenkov light) allows a very compact
approach for particle identification detectors. The PANDA detector at the future FAIR facility at
GSI will use a Barrel-DIRC for the central region and a Disc DIRC for the forward angular region
between 5◦
and 22◦
. It will be the first time that a Disc DIRC is used in a high performance 4π
detector. To achieve this aim, different designs and technologies have been evaluated and tested.
This article will focus on the mechanical design and integration of the Disc DIRC with respect to
the PANDA environment
Frontend electronics for high-precision single photo-electron timing
The next generation of high-luminosity experiments requires excellent particle identification detectors, which calls for imaging Cherenkov counters with fast electronics to cope with the expected hit rates. A Barrel DIRC will be used in the central region of the Target Spectrometer
of the planned PANDA experiment at FAIR. A single photo-electron timing resolution of better
than 100 ps RMS is required for the Barrel DIRC to disentangle the complicated patterns created
on the image plane. R&D studies have been performed to provide a design based on the TRB3
readout using FPGA-TDCs with a typical precision of 10 ps RMS and custom frontend electronics with high-bandwidth pre-amplifiers and fast discriminators. The discriminators also provide
time-over-threshold information, thus enabling walk corrections to improve the timing resolution.
Two types of frontend electronics cards optimised for reading out 64-channel PHOTONIS Planacon MCP-PMTs were tested: one based on the NINO ASIC and the other, called PADIWA, based
on FPGA discriminators. Promising results were obtained in a full characterisation using a fast
laser setup and in a test experiment at MAMI, Mainz, with a small scale DIRC prototype
- …