    Extraocular Surgical Approach for Placement of Subretinal Implants in Blind Patients: Lessons from Cochlear-Implants

    Get PDF
    In hereditary retinal diseases photoreceptors progressively degenerate, often causing blindness without therapy being available. Newly developed subretinal implants can substitute functions of photoreceptors. Retina implant extraocular surgical technique relies strongly on cochlear-implant know-how. However, a completely new surgical approach providing safe handling of the photosensor array had to be developed. The Retina Implant Alpha IMS consisting of a subretinal microphotodiode array and cable linked to a cochlear-implant-like ceramic housing was introduced via a retroauricular incision through a subperiosteal tunnel above the zygoma into the orbit using a specially designed trocar. Implant housing was fixed in a bony bed within a tight subperiosteal pocket in all patients. Primary outcomes were patient short term safety as well as effectiveness. Nine patients participated in the first part of the multicenter trial and received the subretinal visual implant in one eye. In all cases microphotodiode array pull-through procedure and stable positioning were possible without affecting the device function. No intraoperative complications were encountered. The minimally invasive suprazygomatic tunneling technique for the sensor unit as well as a subperiosteal pocket fixation of the implant housing provides a safe extraocular implantation approach of a subretinal device with a transcutaneous extracorporeal power supply

    Interim Results of a Multicenter Trial with the New Electronic Subretinal Implant Alpha AMS in 15 Patients Blind from Inherited Retinal Degenerations

    Get PDF
    Purpose: We assessed the safety and efficacy of a technically advanced subretinal electronic implant, RETINA IMPLANT Alpha AMS, in end stage retinal degeneration in an interim analysis of two ongoing prospective clinical trials. The purpose of this article is to describe the interim functional results (efficacy). Methods: The subretinal visual prosthesis RETINA IMPLANT Alpha AMS (Retina Implant AG, Reutlingen, Germany) was implanted in 15 blind patients with hereditary retinal degenerations at four study sites with a follow-up period of 12 months (www.clinicaltrials.gov NCT01024803 and NCT02720640). Functional outcome measures included (1) screen-based standardized 2- or 4-alternative forced-choice (AFC) tests of light perception, light localization, grating detection (basic grating acuity (BaGA) test), and Landolt C-rings; (2) gray level discrimination; (3) performance during activities of daily living (ADL-table tasks). Results: Implant-mediated light perception was observed in 13/15 patients. During the observation period implant mediated localization of visual targets was possible in 13/15 patients. Correct grating detection was achieved for spatial frequencies of 0.1 cpd (cycles per degree) in 4/15; 0.33 cpd in 3/15; 0.66 cpd in 2/15; 1.0 cpd in 2/15 and 3.3 cpd in 1/15 patients. In two patients visual acuity (VA) assessed with Landolt C- rings was 20/546 and 20/1111. Of 6 possible gray levels on average 4.6 ± 0.8 (mean ± SD, n = 10) were discerned. Improvements (power ON vs. OFF) of ADL table tasks were measured in 13/15 patients. Overall, results were stable during the observation period. Serious adverse events (SAEs) were reported in 4 patients: 2 movements of the implant, readjusted in a second surgery; 4 conjunctival erosion/dehiscence, successfully treated; 1 pain event around the coil, successfully treated; 1 partial reduction of silicone oil tamponade leading to distorted vision (silicon oil successfully refilled). The majority of adverse events (AEs) were transient and mostly of mild to moderate intensity. Conclusions: Psychophysical and subjective data show that RETINA IMPLANT Alpha AMS is reliable, well tolerated and can restore limited visual functions in blind patients with degenerations of the outer retina. Compared with the previous implant Alpha IMS, longevity of the new implant Alpha AMS has been considerably improved. Alpha AMS has meanwhile been certified as a commercially available medical device, reimbursed in Germany by the public health system

    Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss

    Get PDF
    Nowadays, several options are available to treat patients with conductive or mixed hearing loss. Whenever surgical intervention is not possible or contra-indicated, and amplification by a conventional hearing device (e.g., behind-the-ear device) is not feasible, then implantable hearing devices are an indispensable next option. Implantable bone-conduction devices and middle-ear implants have advantages but also limitations concerning complexity/invasiveness of the surgery, medical complications, and effectiveness. To counsel the patient, the clinician should have a good overview of the options with regard to safety and reliability as well as unequivocal technical performance data. The present consensus document is the outcome of an extensive iterative process including ENT specialists, audiologists, health-policy scientists, and representatives/technicians of the main companies in this field. This document should provide a first framework for procedures and technical characterization to enhance effective communication between these stakeholders, improving health care

    Management of chronic rhinosinusitis in CF

    Get PDF
    AbstractRoutine CF management often does not include upper airway (UAW) assessment although CFTR defects equally affect the sinonasal mucosa. Up to 50% of CF patients have chronic rhinosinusitis (CRS) and/or nasal polyps, and almost 100% reveal UAW abnormalities on CT scan. CRS impairs quality of life. UAW dysfunction in filtering, humidifying, and warming inspired air affects lower airways and the UAW is a potential site of first colonization and a reservoir for opportunistic bacteria. Therefore, UAW pathology substantially affects overall health in CF.Standard treatments are scarce and mostly lack evidence. Nasal douche can remove mucus and crusts. Recently, delivery of dornase alfa using a vibrating aerosol has shown potential as treatment for CF-related CRS. Surgery is indicated when conservative approaches fail but postoperative relapse is frequent.In summary, upper airway involvement in CF is undertreated and requires prospective investigation and an interdisciplinary consensus on diagnosis and therapy

    Early detection of sensorineural hearing loss in Muckle-Wells-syndrome

    No full text
    Abstract Background Muckle-Wells-syndrome (MWS) is an autoinflammatory disease characterized by systemic and organ-specific inflammation due to excessive interleukin (IL)-1 release. Inner ear inflammation results in irreversible sensorineural hearing loss, if untreated. Early recognition and therapy may prevent deafness. The aims of the study were to characterize the spectrum of hearing loss, optimize the otologic assessment for early disease and determine responsiveness to anti-IL-1-therapy regarding hearing. Methods A single center prospective cohort study of children and adults with MWS was performed. Standardized clinical, laboratory and otologic assessments including standard pure tone audiometry, additional high tone thresholds, vestibular organ testing, tinnitus evaluation and functional disability classes were determined serially. Pure-tone-average models were developed and evaluated. Risk factors for hearing loss and the impact of anti-IL-1 treatment were determined. Results A total of 23 patients with genetically confirmed MWS were included, of whom 63 % were females; 52 % were children. At baseline all patients had active MWS; 91 % reported clinically impaired hearing with 74 % having an abnormal standard assessment (0.5–4 kHz). In contrast, high frequency pure tone averages (HF-PTA) were abnormal in all symptomatic patients including those with early hearing loss (sensitivity 100 %). Females were at highest risk for hearing loss even after adjustment for age (p = 0.008). Treatment with IL-1 blockade resulted in improved or stable hearing in 91 % of patients. Conclusions Early inner ear inflammation in MWS primarily affects the high frequencies, beyond the range of standard otologic assessment tools. The HF-PTA is a sensitive tool to detect imminent hearing loss and monitor treatment response

    Paediatric Cogan´s syndrome - review of literature, case report and practical approach to diagnosis and management

    No full text
    Abstract Background Cogan´s syndrome is a rare, presumed autoimmune vasculitis of various vessels characterized by interstitial keratitis and vestibular impairment accompanied by sensorineural hearing loss. Due to the rarity of Cogan´s syndrome in children, therapeutic decision making may be challenging. Therefore, a literature search was performed to collect all published paediatric Cogan´s syndrome cases with their clinical characteristics, disease course, treatment modalities used and their outcome. The cohort was supplemented with our own patient. Main text Altogether, 55 paediatric Cogan´s syndrome patients aged median 12 years have been reported so far. These were identified in PubMed with the keywords “Cogan´s syndrome” and “children” or “childhood”. All patients suffered from inflammatory ocular and vestibulo-auditory symptoms. In addition, 32/55 (58%) manifested systemic symptoms with musculoskeletal involvement being the most common with a prevalence of 45%, followed by neurological and skin manifestations. Aortitis was detected in 9/55 (16%). Regarding prognosis, remission in ocular symptoms was attained in 69%, whereas only 32% achieved a significant improvement in auditory function. Mortality was 2/55. Our patient was an 8 year old girl who presented with bilateral uveitis and a history of long standing hearing deficit. She also complained of intermittent vertigo, subfebrile temperatures, abdominal pain with diarrhoea, fatigue and recurrent epistaxis. The diagnosis was supported by bilateral labyrinthitis seen on contrast-enhanced magnetic resonance imaging. Treatment with topical and systemic steroids was started immediately. As the effect on auditory function was only transient, infliximab was added early in the disease course. This led to a remission of ocular and systemic symptoms and a normalization of hearing in the right ear. Her left ear remained deaf and the girl is currently evaluated for a unilateral cochlear implantation. Conclusions This study presents an analysis of the largest cohort of paediatric Cogan´s syndrome patients. Based on the collected data, the first practical guide to a diagnostic work-up and treatment in children with Cogan´s syndrome is provided

    Additional file 2: Table S2. of Early detection of sensorineural hearing loss in Muckle-Wells-syndrome

    No full text
    Age-group specific median limits of normal hearing (calculated from Spoor 1967 [25], for the 4-frequency pure tone average (4PTA0.5-4kHz) and the proposed high-frequency pure tone average (HF-PTA6,8kHz). Because of very minor gender differences, especially in the younger age groups, male and female data were combined. (DOC 51 kb
    corecore