677 research outputs found
Evidence-informed health policy: are we beginning to get there at last
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
Nonequilibrium Singlet-Triplet Kondo Effect in Carbon Nanotubes
The Kondo-effect is a many-body phenomenon arising due to conduction
electrons scattering off a localized spin. Coherent spin-flip scattering off
such a quantum impurity correlates the conduction electrons and at low
temperature this leads to a zero-bias conductance anomaly. This has become a
common signature in bias-spectroscopy of single-electron transistors, observed
in GaAs quantum dots as well as in various single-molecule transistors. While
the zero-bias Kondo effect is well established it remains uncertain to what
extent Kondo correlations persist in non-equilibrium situations where inelastic
processes induce decoherence. Here we report on a pronounced conductance peak
observed at finite bias-voltage in a carbon nanotube quantum dot in the spin
singlet ground state. We explain this finite-bias conductance anomaly by a
nonequilibrium Kondo-effect involving excitations into a spin triplet state.
Excellent agreement between calculated and measured nonlinear conductance is
obtained, thus strongly supporting the correlated nature of this nonequilibrium
resonance.Comment: 21 pages, 5 figure
Conditional statistics of electron transport in interacting nanoscale conductors
Interactions between nanoscale semiconductor structures form the basis for
charge detectors in the solid state. Recent experimental advances have
demonstrated the on-chip detection of single electron transport through a
quantum dot (QD). The discreteness of charge in units of e leads to intrinsic
fluctuations in the electrical current, known as shot noise. To measure these
single-electron fluctuations a nearby coherent conductor, called a quantum
point contact (QPC), interacts with the QD and acts as a detector. An important
property of the QPC charge detector is noninvasiveness: the system physically
affects the detector, not visa-versa. Here we predict that even for ideal
noninvasive detectors such as the QPC, when a particular detector result is
observed, the system suffers an informational backaction, radically altering
the statistics of transport through the QD as compared to the unconditional
shot noise. We develop a theoretical model to make predictions about the joint
current probability distributions and conditional transport statistics. The
experimental findings reported here demonstrate the reality of informational
backaction in nanoscale systems as well as a variety of new effects, such as
conditional noise enhancement, which are in essentially perfect agreement with
our model calculations. This type of switching telegraph process occurs
abundantly in nature, indicating that these results are applicable to a wide
variety of systems.Comment: 16 pages, 3 figures, to appear in Nature Physic
The role of magnetic anisotropy in the Kondo effect
In the Kondo effect, a localized magnetic moment is screened by forming a
correlated electron system with the surrounding conduction electrons of a
non-magnetic host. Spin S=1/2 Kondo systems have been investigated extensively
in theory and experiments, but magnetic atoms often have a larger spin. Larger
spins are subject to the influence of magnetocrystalline anisotropy, which
describes the dependence of the magnetic moment's energy on the orientation of
the spin relative to its surrounding atomic environment. Here we demonstrate
the decisive role of magnetic anisotropy in the physics of Kondo screening. A
scanning tunnelling microscope is used to simultaneously determine the
magnitude of the spin, the magnetic anisotropy and the Kondo properties of
individual magnetic atoms on a surface. We find that a Kondo resonance emerges
for large-spin atoms only when the magnetic anisotropy creates degenerate
ground-state levels that are connected by the spin flip of a screening
electron. The magnetic anisotropy also determines how the Kondo resonance
evolves in a magnetic field: the resonance peak splits at rates that are
strongly direction dependent. These rates are well described by the energies of
the underlying unscreened spin states.Comment: 14 pages, 4 figures, published in Nature Physic
Quantum phase transition in a single-molecule quantum dot
Quantum criticality is the intriguing possibility offered by the laws of
quantum mechanics when the wave function of a many-particle physical system is
forced to evolve continuously between two distinct, competing ground states.
This phenomenon, often related to a zero-temperature magnetic phase transition,
can be observed in several strongly correlated materials such as heavy fermion
compounds or possibly high-temperature superconductors, and is believed to
govern many of their fascinating, yet still unexplained properties. In contrast
to these bulk materials with very complex electronic structure, artificial
nanoscale devices could offer a new and simpler vista to the comprehension of
quantum phase transitions. This long-sought possibility is demonstrated by our
work in a fullerene molecular junction, where gate voltage induces a crossing
of singlet and triplet spin states at zero magnetic field. Electronic tunneling
from metallic contacts into the quantum dot provides here the
necessary many-body correlations to observe a true quantum critical behavior.Comment: 8 pages, 5 figure
The development and application of a new tool to assess the adequacy of the content and timing of antenatal care
Abstract
Background: Current measures of antenatal care use are limited to initiation of care and number of visits. This
study aimed to describe the development and application of a tool to assess the adequacy of the content and
timing of antenatal care.
Methods: The Content and Timing of care in Pregnancy (CTP) tool was developed based on clinical relevance for
ongoing antenatal care and recommendations in national and international guidelines. The tool reflects minimal
care recommended in every pregnancy, regardless of parity or risk status. CTP measures timing of initiation of care,
content of care (number of blood pressure readings, blood tests and ultrasound scans) and whether the
interventions were received at an appropriate time. Antenatal care trajectories for 333 pregnant women were then
described using a standard tool (the APNCU index), that measures the quantity of care only, and the new CTP tool.
Both tools categorise care into 4 categories, from âInadequateâ (both tools) to âAdequate plusâ (APNCU) or
âAppropriateâ (CTP). Participants recorded the timing and content of their antenatal care prospectively using diaries.
Analysis included an examination of similarities and differences in categorisation of care episodes between the
tools.
Results: According to the CTP tool, the care trajectory of 10,2% of the women was classified as inadequate, 8,4%
as intermediate, 36% as sufficient and 45,3% as appropriate. The assessment of quality of care differed significantly
between the two tools. Seventeen care trajectories classified as âAdequateâ or âAdequate plusâ by the APNCU were
deemed âInadequateâ by the CTP. This suggests that, despite a high number of visits, these women did not receive
the minimal recommended content and timing of care.
Conclusions: The CTP tool provides a more detailed assessment of the adequacy of antenatal care than the
current standard index. However, guidelines for the content of antenatal care vary, and the tool does not at the
moment grade over-use of interventions as âInappropriateâ. Further work needs to be done to refine the content
items prior to larger scale testing of the impact of the new measure
Shot noise in mesoscopic systems
This is a review of shot noise, the time-dependent fluctuations in the
electrical current due to the discreteness of the electron charge, in small
conductors. The shot-noise power can be smaller than that of a Poisson process
as a result of correlations in the electron transmission imposed by the Pauli
principle. This suppression takes on simple universal values in a symmetric
double-barrier junction (suppression factor 1/2), a disordered metal (factor
1/3), and a chaotic cavity (factor 1/4). Loss of phase coherence has no effect
on this shot-noise suppression, while thermalization of the electrons due to
electron-electron scattering increases the shot noise slightly. Sub-Poissonian
shot noise has been observed experimentally. So far unobserved phenomena
involve the interplay of shot noise with the Aharonov-Bohm effect, Andreev
reflection, and the fractional quantum Hall effect.Comment: 37 pages, Latex, 10 figures (eps). To be published in "Mesoscopic
Electron Transport," edited by L. P. Kouwenhoven, G. Schoen, and L. L. Sohn,
NATO ASI Series E (Kluwer Academic Publishing, Dordrecht
Extreme Technicolor & The Walking Critical Temperature
We map the phase diagram of gauge theories of fundamental interactions in the
flavor-temperature plane using chiral perturbation theory to estimate the
relation between the pion decaying constant and the critical temperature above
which chiral symmetry is restored. We then investigate the impact of our
results on models of dynamical electroweak symmetry breaking and therefore on
the electroweak early universe phase transition.Comment: RevTeX, 18 pages, 3 figure
Teaching Feedback to First-year Medical Students: Long-term Skill Retention and Accuracy of Student Self-assessment
Giving and receiving feedback are critical skills and should be taught early in the process of medical education, yet few studies discuss the effect of feedback curricula for first-year medical students.
To study short-term and long-term skills and attitudes of first-year medical students after a multidisciplinary feedback curriculum.
Prospective pre- vs. post-course evaluation using mixed-methods data analysis.
First-year students at a public university medical school.
We collected anonymous student feedback to faculty before, immediately after, and 8 months after the curriculum and classified comments by recommendation (reinforcing/corrective) and specificity (global/specific). Students also self-rated their comfort with and quality of feedback. We assessed changes in comments (skills) and self-rated abilities (attitudes) across the three time points.
Across the three time points, studentsâ evaluation contained more corrective specific comments per evaluation [pre-curriculum mean (SD) 0.48 (0.99); post-curriculum 1.20 (1.7); year-end 0.95 (1.5); pâ=â0.006]. Students reported increased skill and comfort in giving and receiving feedback and at providing constructive feedback (pâ<â0.001). However, the number of specific comments on year-end evaluations declined [pre 3.35 (2.0); post 3.49 (2.3); year-end 2.8 (2.1)]; pâ=â0.008], as did studentsâ self-rated ability to give specific comments.
Teaching feedback to early medical students resulted in improved skills of delivering corrective specific feedback and enhanced comfort with feedback. However, studentsâ overall ability to deliver specific feedback decreased over time
- âŠ