4,167 research outputs found

    ATLAS Detector Commissioning with Photons

    Get PDF
    An intense commissioning activity of the ATLAS detector has preceded the LHC beam start up. Both cosmics events and in earlier periods test beam events have been utilized. The commission- ing of the ATLAS detector using photons has been an integral part of this effort. In this paper we present the results of these activities following a discussion of the reconstruction of photons in the ATLAS detector

    Mobility of thorium ions in liquid xenon

    Full text link
    We present a measurement of the 226^{226}Th ion mobility in LXe at 163.0 K and 0.9 bar. The result obtained, 0.240±\pm0.011 (stat) ±\pm0.011 (syst) cm2^{2}/(kV-s), is compared with a popular model of ion transport.Comment: 6.5 pages,

    Investigation of radioactivity-induced backgrounds in EXO-200

    Full text link
    The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and {\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta} experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.Comment: 9 pages, 7 figures, 3 table

    ATLAS Detector Paper Back-Up Note: Electrons and Photons

    Get PDF
    This is the supporting note to the ATLAS Detector paper for electron and photon reconstruction with the Inner Detector. It describes the software used to produce the results presented in the ATLAS Detector paper

    Searches for Double Beta Decay of 134^{134}Xe with EXO-200

    Get PDF
    Searches for double beta decay of 134^{134}Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of 136^{136}Xe. Using an exposure of 29.6 kg ⁣ ⁣yr29.6\text{ kg}\!\cdot\!\text{yr}, the lower limits of T1/22νβ ⁣β>8.71020 yr\text{T}_{1/2}^{2\nu\beta\!\beta}>8.7\cdot10^{20}\text{ yr} and T1/20νβ ⁣β>1.11023 yr\text{T}_{1/2}^{0\nu\beta\!\beta}>1.1\cdot10^{23}\text{ yr} at 90% confidence level were derived, with corresponding half-life sensitivities of 1.21021 yr1.2\cdot10^{21}\text{ yr} and 1.91023 yr1.9\cdot10^{23}\text{ yr}. These limits exceed those in the literature for 134^{134}Xe, improving by factors of nearly 10510^{5} and 2 for the two antineutrino and neutrinoless modes, respectively.Comment: 8 pages, 4 figure

    Search for nucleon decays with EXO-200

    Get PDF
    A search for instability of nucleons bound in 136^{136}Xe nuclei is reported with 223 kg\cdotyr exposure of 136^{136}Xe in the EXO-200 experiment. Lifetime limits of 3.3×1023\times 10^{23} and 1.9×1023\times 10^{23} yrs are established for nucleon decay to 133^{133}Sb and 133^{133}Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively

    Characterization of an Ionization Readout Tile for nEXO

    Full text link
    A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3~mm wide, on a 10~\si{\cm} ×\times 10~\si{\cm} fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207^{207}Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution σ/E\sigma/E=5.5\% is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936~V/\si{cm}.Comment: 18 pages, 13 figures, as publishe
    corecore