25 research outputs found

    Validation and Implementation of a Highly Sensitive and Efficient Newborn Screening Assay for Mucopolysaccharidosis Type II

    No full text
    Mucopolysaccharidosis Type II (MPS II), also known as Hunter syndrome, is a lysosomal storage disorder (LSD) caused by a deficiency of the lysosomal enzyme iduronate-2-sulfatase (IDS). MPS II satisfies all criteria defined by the Advisory Committee on Heritable Disorders in Newborns and Children (ACHDNC) for inclusion in the Recommended Uniform Screening Panel (RUSP) for newborn screening, apart from the fact that only minimal prospective population screening data are available. This report details the analytical validation, clinical validation, and implementation of a fluorometric assay for measurement of IDS activity in newborn dried blood spot (DBS) specimens at the Missouri State Public Health Laboratory (MSPHL). The assay is performed in a microwell plate format requiring approximately 15 min of hands-on time per plate and an incubation time of two hours. The analytical validation of this assay included linearity, analytical sensitivity, precision, and carry-over testing. Clinical validation was completed using more than 5000 deidentified presumptive normal newborn DBS specimens as well as seven specimens from patients known to be affected with MPS II. Following validation, MSPHL began prospective screening using the IDS assay on 1 November 2018. In the first 18 months of screening (to 30 June 2020), 146,954 specimens were prospectively screened using the method. Two newborns were identified with severe Hunter syndrome and the assay had a presumptive positive rate of 0.022%

    Newborn Screening for Krabbe Disease: Status Quo and Recommendations for Improvements

    No full text
    Krabbe disease (KD) is part of newborn screening (NBS) in 11 states with at least one additional state preparing to screen. In July 2021, KD was re-nominated for addition to the federal Recommended Uniform Screening Panel (RUSP) in the USA with a two-tiered strategy based on psychosine (PSY) as the determinant if an NBS result is positive or negative after a first-tier test revealed decreased galactocerebrosidase activity. Nine states currently screening for KD include PSY analysis in their screening strategy. However, the nomination was rejected in February 2023 because of perceived concerns about a high false positive rate, potential harm to newborns with an uncertain prognosis, and inadequate data on presymptomatic treatment benefit or harm. To address the concern about false positive NBS results, a survey was conducted of the eight NBS programs that use PSY and have been screening for KD for at least 1 year. Seven of eight states responded. We found that: (1) the use of PSY is variable; (2) when modeling the data based on the recommended screening strategy for KD, and applying different cutoffs for PSY, each state could virtually eliminate false positive results without major impact on sensitivity; (3) the reason for the diverse strategies appears to be primarily the difficulty of state programs to adjust screening algorithms due to the concern of possibly missing even an adult-onset case following a change that focuses on infantile and early infantile KD. Contracts with outside vendors and the effort/cost of making changes to a program’s information systems can be additional obstacles. We recommend that programs review their historical NBS outcomes for KD with their advisory committees and make transparent decisions on whether to accept false positive results for such a devastating condition or to adjust their procedures to ensure an efficient, effective, and manageable NBS program for KD

    Liquid Chromatography–Tandem Mass Spectrometry in Newborn Screening Laboratories

    No full text
    Tandem mass spectrometry (MS/MS) is the most universal platform currently available for the analysis of enzymatic activities and biomarkers in dried blood spots (DBS) for applications in newborn screening (NBS). Among the MS/MS applications in NBS, the most common is flow-injection analysis (FIA-) MS/MS, where the sample is introduced as a bolus injection into the mass spectrometer without the prior fractionation of analytes. Liquid chromatography combined with MS/MS (LC-MS/MS) has been employed for second-tier tests to reduce the false-positive rate associated with several nonspecific screening markers, beginning two decades ago. More recently, LC-MS/MS has been applied to primary screening for new conditions for which FIA-MS/MS or other methods, including genomic screening, are not yet adequate. In addition to providing a list of the currently used LC-MS/MS-based assays for NBS, the authors share their experience regarding the maintenance requirements of LC-MS/MS vs. FIA-MS/MS systems. The consensus is that the maintenance of LC-MS/MS and FIA-MS/MS instrumentation is similar, and LC-MS/MS has the advantage of allowing for a larger number of diseases to be screened for in a multiplex, cost-effective fashion with a high throughput and an adequate turnaround time
    corecore