127 research outputs found

    A Cadaveric Study Validating in vitro Monitoring Techniques to Measure the Failure Mechanism of Glenoid Implants against Clinical CT

    Get PDF
    Definite glenoid implant loosening is identifiable on radiographs, however, identifying early loosening still eludes clinicians. Methods to monitor glenoid loosening in vitro have not been validated to clinical imaging. This study investigates the correlation between in vitro measures and CT images. Ten cadaveric scapulae were implanted with a pegged glenoid implant and fatigue tested to failure. Each scapulae were cyclically loaded superiorly and CT scanned every 20,000 cycles until failure to monitor progressive radiolucent lines. The superior and inferior rim displacements were also measured. A finite element (FE) model of one scapula was used to analyse the interfacial stresses at the implant/cement and cement/bone. All ten implants failed inferiorly at the implant-cement interface, two also failed at the cement-bone interface inferiorly, and three showed superior failure. Failure occurred at of 80,966 ± 53,729 (mean ± SD) cycles. CT scans confirmed failure of the fixation, and in most cases, was observed either before or with visual failure, indicating its capacity to detect loosening earlier for earlier intervention if needed. Significant correlations were found between both increasing inferior rim displacement (ASTM standard F2028-14), increasing vertical head displacement and failure of the glenoid implant. The FE model showed peak tensile stresses inferiorly and high compressive stresses superiorly, corroborating experimental findings. Similar failure modes have been cited in clinical and in vitro studies. In vitro monitoring methods correlated to failure progression in clinical CT images. Clinical Significance: The study highlights failure at the implant-cement interface and early signs of failure are identifiable in CT images

    Bone marrow mesenchymal stem cells do not enhance intra-synovial tendon healing despite engraftment and homing to niches within the synovium

    Get PDF
    Intra-synovial tendon injuries display poor healing, which often results in reduced functionality and pain. A lack of effective therapeutic options has led to experimental approaches to augment natural tendon repair with autologous mesenchymal stem cells (MSCs) although the effects of the intra-synovial environment on the distribution, engraftment and functionality of implanted MSCs is not known. This study utilised a novel sheep model which, although in an anatomically different location, more accurately mimics the mechanical and synovial environment of the human rotator cuff, to determine the effects of intra-synovial implantation of MSCs

    Failure mechanism of the all-polyethylene glenoid implant

    Get PDF
    Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due to the fundamental problem that direct observations of failure are impossible as the fixation is inherently embedded within the bone. Twenty custom made implants, reflecting various common fixation designs, and a specimen set-up was prepared to enable direct observation of failure when the specimens were exposed to cyclic superior loads during laboratory experiments. Finite element analyses of the laboratory tests were also carried out to explain the observed failure scenarios. All implants, irrespective of the particular fixation design, failed at the implant-cement interface and failure initiated at the inferior part of the component fixation. Finite element analyses indicated that this failure scenario was caused by a weak and brittle implant-cement interface and tensile stresses in the inferior region possibly worsened by a stress raiser effect at the inferior rim. The results of this study indicate that glenoid failure can be delayed or prevented by improving the implant/cement interface strength. Also any design features that reduce the geometrical stress raiser and the inferior tensile stresses in general should delay implant loosening

    Development of a 3D workspace Shoulder Assessment Tool Incorporating Electromyography and an Inertial Measurement Unit - A preliminary study

    Get PDF
    Traditional shoulder Range of Movement (ROM) measurement tools suffer from inaccuracy or from long experimental set-up times. Recently, it has been demonstrated that relatively low-cost wearable inertial measurement unit (IMU) sensors can overcome many of the limitations of traditional motion tracking systems. The aim of this study is to develop and evaluate a single IMU combined with an Electromyography (EMG) sensor to monitor the 3D reachable workspace with simultaneous measurement of deltoid muscle activity across the shoulder ROM. Six volunteer subjects with healthy shoulders and one participant with a ‘frozen’ shoulder were recruited to the study. Arm movement in 3D space was plotted in spherical coordinates while the relative EMG intensity of any arm position is presented graphically. The results showed that there was an average ROM surface area of 27291±538 deg2 among all six healthy individuals and a ROM surface area of 13571±308 deg2 for the subject with frozen shoulder. All three sections of the deltoid show greater EMG activity at higher elevation angles. Using such tools enables individuals, surgeons and physiotherapists to measure the maximum envelope of motion in conjunction with muscle activity in order to provide an objective assessment of shoulder performance in the voluntary 3D workspace

    Interference Screw vs. Suture Anchor Fixation for Open Subpectoral Biceps Tenodesis: Does it Matter?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Bioabsorbable interference screw fixation has superior biomechanical properties compared to suture anchor fixation for biceps tenodesis. However, it is unknown whether fixation technique influences clinical results.</p> <p>Hypothesis</p> <p>We hypothesize that subpectoral interference screw fixation offers relevant clinical advantages over suture anchor fixation for biceps tenodesis.</p> <p>Study Design</p> <p>Case Series.</p> <p>Methods</p> <p>We performed a retrospective review of a consecutive series of 88 patients receiving open subpectoral biceps tenodesis with either interference screw fixation (34 patients) or suture anchor fixation (54 patients). Average follow up was 13 months. Outcomes included Visual Analogue Pain Scale (0–10), ASES score, modified Constant score, pain at the tenodesis site, failure of fixation, cosmesis, deformity (popeye) and complications.</p> <p>Results</p> <p>There were no failures of fixation in this study. All patients showed significant improvement between their preoperative and postoperative status with regard to pain, ASES score, and abbreviated modified Constant scores. When comparing IF screw versus anchor outcomes, there was no statistical significance difference for VAS (p = 0.4), ASES score (p = 0.2), and modified Constant score (P = 0.09). One patient (3%) treated with IF screw complained of persistent bicipital groove tenderness, versus four patients (7%) in the SA group (nonsignificant).</p> <p>Conclusion</p> <p>Subpectoral biceps tenodesis reliably relieves pain and improves function. There was no statistically significant difference in the outcomes studied between the two fixation techniques. Residual pain at the site of tenodesis may be an issue when suture anchors are used in the subpectoral location.</p
    corecore