56 research outputs found

    Construction and Demonstration of a 6–18 GHz Microwave Three-Wave Mixing Experiment using Multiple Synchronized Arbitrary Waveform Generators

    Get PDF
    This manuscript details the construction and demonstration of the first known microwave three-wave mixing (M3WM) experiment utilizing multiple arbitrary waveform generators (AWGs) completely operable in the 6–18 GHz frequency range for use in chirality determination and quantification. Many M3WM techniques, which involve two orthogonal, subsequent Rabi π/2 and π microwave pulses, suffer from flexibility in pulse types and timings as well as frequency due to most instruments only using one, one-channel AWG and the M3WM probability decreasing with an increasing quantum number, J. In this work, we presented an M3WM instrument that allows that flexibility by introducing multiple, synchronized AWGs and adheres to the high probability transition loop pathways in carvone. The functionality and reliability of the instrument were demonstrated using a series of experiments and mixtures of the R and S enantiomers and determined to be of similar accuracy to other reported M3WM setups with the additional benefit of flexibility in pulsing schemes

    Solid State NMR Spectroscopy/Imaging in Situ Measuring Devices and Methods for Calibration and Determining One or More Quantitative Properties of a Target SampleAbstract

    Get PDF
    In situ measuring devices, methods of making the same, and methods of using the same are provided herein. The in situ measuring devices can include a capillary tube having a reference material sealed inside the capillary tube, where the capillary tube is positioned inside of a solid state or MAS NMR rotor. A target sample can also be positioned in the interior of the solid state or MAS NMR rotor but is sequestered from the reference material by a capillary tube wall. The in situ measuring devices can be used in solid state MAS NMR spectroscopy to quantify one or more parameters of a target sample, such as the quantity of a sample, chemical identity of a sample, or temperature of a sample

    Solid State NMR Spectroscopy/Imaging in Situ Measuring Devices and Methods for Calibration and Determining One or More Quantitative Properties of a Target Sample

    Get PDF
    In situ measuring devices, methods of making the same, and methods of using the same are provided herein. The in situ measuring devices can include a capillary tube having a reference material sealed inside the capillary tube, where the capillary tube is positioned inside of a solid state or MAS NMR rotor. A target sample can also be positioned in the interior of the solid state or MAS NMR rotor but is sequestered from the reference material by a capillary tube wall. The in situ measuring devices can be used in solid state MAS NMR spectroscopy to quantify one or more parameters of a target sample, such as the quantity of a sample, chemical identity of a sample, or temperature of a sample

    In Situ NMR Parameter Monitoring Systems and Methods for Measuring PH and Temperature

    Get PDF
    Devices and methods are provided for measuring temperatures and pHs of a sample in situ using NMR spectroscopy, and for sealing one or more ends of a capillary tube after a reference material has been added to the capillary tube, which is used in an in situ NMR temperature measurement device. A method for measuring a pH of a sample in situ using NMR spectroscopy includes providing an in situ NMR pH measurement device. This device includes a sample housing member configured to house a target sample, at least one pH sensor configured to exhibit an NMR spectral change due to a change in pH value of the target sample, and a pH sensor containment member configured to house the at least one pH sensor. The target sample is added to the sample housing member. NMR spectra are obtained to then determine the pH of the target sample

    Capillary-Tube Package Devices for the Quantitative Performance Evaluation of Nuclear Magnetic Resonance Spectrometers and Pulse Sequences

    Get PDF
    With the increased sensitivity of modern nuclear magnetic resonance (NMR) spectrometers, the minimum amount needed for chemical-shift referencing of NMR spectra has decreased to a point where a few microliters can be sufficient to observe a reference signal. The reduction in the amount of required reference material is the basis for the NMR Capillary-tube Package (CapPack) platform that utilizes capillary tubes with inner diameters smaller than 150 ”m as NMR-tube inserts for external reference standards. It is shown how commercially available electrophoresis capillary tubes with outer diameters of 360 ”m are filled with reference liquids or solutions and then permanently sealed by the arc discharge plasma of a commercially available fusion splicer normally employed for joining optical fibers. The permanently sealed capillaries can be used as external references for chemical-shift, signal-to-noise, resolution, and concentration calibration. Combining a number of permanently sealed capillaries to form CapPack devices leads to additional applications such as performance evaluation of NMR spectrometers and NMR pulse sequences. A 10-capillary-tube side-by-side Gradient CapPack device is used in combination with one or two constant gradients, produced by room-temperature shim coils, to monitor the excitation profiles of shaped pulses. One example illustrates the performance of hyperbolic secant (sech) pulses in the EXponentially Converging Eradication Pulse Train (EXCEPT) solvent suppression sequence. The excitation profile of the pulse sequence is obtained in a single gradient NMR experiment. A clustered T1 CapPack device is introduced consisting of a coaxial NMR-tube insert that holds seven capillary tubes filled with aqueous solutions of different concentrations of the paramagnetic relaxation agent copper(ii) sulfate (CuSO4). The different CuSO4 concentrations lead to spin-lattice relaxation times in the seven capillary tubes that cover a range which extends to more than an order of magnitude. Clustered T1 CapPack devices are best suited to quantify the effects that relaxation has on magnetizations and coherences during the execution of NMR experiments, which is demonstrated for the order-of-magnitude T1 insensitivity of signal suppression with EXCEPT

    Theranostic Copolymers Neutralize Reactive Oxygen Species and Lipid Peroxidation Products for the Combined Treatment of Traumatic Brain Injury

    Get PDF
    Traumatic brain injury (TBI) results in the generation of reactive oxygen species (ROS) and lipid peroxidation product (LPOx), including acrolein and 4-hydroxynonenal (4HNE). The presence of these biochemical derangements results in neurodegeneration during the secondary phase of the injury. The ability to rapidly neutralize multiple species could significantly improve outcomes for TBI patients. However, the difficulty in creating therapies that target multiple biochemical derangements simultaneously has greatly limited therapeutic efficacy. Therefore, our goal was to design a material that could rapidly bind and neutralize both ROS and LPOx following TBI. To do this, a series of thiol-functionalized biocompatible copolymers based on lipoic acid methacrylate and polyethylene glycol monomethyl ether methacrylate (FW ∌950 Da) (O950) were prepared. A polymerizable gadolinium-DOTA methacrylate monomer (Gd-MA) was also synthesized starting from cyclen to facilitate direct magnetic resonance imaging and in vivo tracking of accumulation. These neuroprotective copolymers (NPCs) were shown to rapidly and effectively neutralize both ROS and LPOx. Horseradish peroxidase absorbance assays showed that the NPCs efficiently neutralized H2O2, while R-phycoerythrin protection assays demonstrated their ability to protect the fluorescent protein from oxidative damage. 1H NMR studies indicated that the thiol-functional NPCs rapidly form covalent bonds with acrolein, efficiently removing it from solution. In vitro cell studies with SH-SY5Y-differentiated neurons showed that NPCs provide unique protection against toxic concentrations of both H2O2and acrolein. NPCs rapidly accumulate and are retained in the injured brain in controlled cortical impact mice and reduce post-traumatic oxidative stress. Therefore, these materials show promise for improved target engagement of multiple biochemical derangements in hopes of improving TBI therapeutic outcomes

    Leibhafte Kunst. Statuen und kulturelle IdentitÀt

    Get PDF
    Dreidimensionale lebensgroße Figuren gehören zu den wirkmĂ€chtigen und auffĂ€lligsten Artikulationsformen der griechischen und römischen Antike. Wegen ihrer Anschaulichkeit sowie wegen ihrer dauernden und körperhaften PrĂ€senz sind sie besonders einflussreiche Konkretisierungen von religiösen Auffassungen, MachtverhĂ€ltnissen und Wissensordnungen. SpĂ€tere Epochen der europĂ€ischen Kulturgeschichte haben sich in immer neuen RĂŒckbezĂŒgen daran orientiert. Der vorliegende Band untersucht die Leistung der Statu­en als eine Konkretisierungsform von politischen, sozia­len und religiösen Vorstellungen. Den Ausgangspunkt bilden PhĂ€nomene der griechischen und römischen Antike, doch machen BeitrĂ€ge aus der Kunstgeschichte, Ethnologie und Germanistik deutlich, dass das Thema weit ĂŒber die Altertumswissenschaften hinaus interessant und wichtig ist. Gerade der Blick auf außereuropĂ€ische Ausdrucksformen macht deutlich, dass die Entwicklung der antiken Skulptur, die aus einer europĂ€ischen Per­spektive konsequent und selbstverstĂ€ndlich erscheint, nur eine unter vielen möglichen Optionen darstellte

    Positive Selection Results in Frequent Reversible Amino Acid Replacements in the G Protein Gene of Human Respiratory Syncytial Virus

    Get PDF
    Human respiratory syncytial virus (HRSV) is the major cause of lower respiratory tract infections in children under 5 years of age and the elderly, causing annual disease outbreaks during the fall and winter. Multiple lineages of the HRSVA and HRSVB serotypes co-circulate within a single outbreak and display a strongly temporal pattern of genetic variation, with a replacement of dominant genotypes occurring during consecutive years. In the present study we utilized phylogenetic methods to detect and map sites subject to adaptive evolution in the G protein of HRSVA and HRSVB. A total of 29 and 23 amino acid sites were found to be putatively positively selected in HRSVA and HRSVB, respectively. Several of these sites defined genotypes and lineages within genotypes in both groups, and correlated well with epitopes previously described in group A. Remarkably, 18 of these positively selected tended to revert in time to a previous codon state, producing a “flip-flop” phylogenetic pattern. Such frequent evolutionary reversals in HRSV are indicative of a combination of frequent positive selection, reflecting the changing immune status of the human population, and a limited repertoire of functionally viable amino acids at specific amino acid sites

    How Heavy Are You? Find the Answer in the Periodic Table

    No full text
    In a classroom or take-home activity, students are challenged to write their name as a combination of chemical-element symbols and calculate their molar mass. Age-appropriate versions ranging from middle school to entry-level college classes are discussed. Acceptable molar-mass suggestions may be used in a competition for the heaviest combination or weighed against a preset value derived from the teacher\u27s name. The activity is suited for exploring information provided with the periodic table at times when atomic and molar masses are first introduced

    Optimizing the Use of Personal Response Devices (Clickers) in Large-Enrollment Introductory Courses

    No full text
    Clickers are electronic response devices with which a student can remotely submit responses to questions or problems posed by a teacher. The problems are typically true-false or multiple-choice questions, but can also include numerical problems. Clicker devices are particularly popular in large-enrollment introductory science, technology, engineering, and mathematics courses. A taxonomy of clicker use is introduced to classify the wide variety of tasks that may be accomplished with clickers. The taxonomy distinguishes between two key categories. The first category relates to questions probing attendance in class, preparedness of assigned reading, and interest in the subject matter. The second category pertains to activities for the enhancement of conceptual understanding and mastering of the material. It involves connecting clicker use to teaching and learning strategies that are thought-provoking, such as peer instruction and problem-based learning. Categories and subcategories are illustrated with key examples of clicker questions from a nonmajor introductory general chemistry course at the college or university level
    • 

    corecore