26 research outputs found

    EXPLORING PERCEPTIONS AND UNVEILING BARRIERS: ACCESS TO ACADEMIC RESEARCH EXPERIENCES FOR UNDERGRADUATE STUDENTS

    Get PDF
    What are the implications for undergraduate students seeking higher education but have never been exposed to research experiences, either as a participant in a faculty-mentored experience, a federal research initiative/training grant, or as a participant (N-1)? This study addresses multiple variables and their potential to increase or decrease research participation among undergraduate students at two regional universities. This study also investigates to what extent Critical Race Theory tenets correlate with the increase or decrease of research participation among undergraduate students

    Feasibility and validity of a low-cost racing simulator in driving assessment after stroke

    Get PDF
    There is a myriad of methodologies to assess driving performance after a stroke. These include psychometric tests, driving simulation, questionnaires, and/or road tests. Research-based driving simulators have emerged as a safe, convenient way to assess driving performance after a stroke. Such traditional research simulators are useful in recreating street traffic scenarios, but are often expensive, with limited physics models and graphics rendering. In contrast, racing simulators developed for motorsport professionals and enthusiasts offer high levels of realism, run on consumer-grade hardware, and can provide rich telemetric data. However, most offer limited simulation of traffic scenarios. This pilot study compares the feasibility of research simulation and racing simulation in a sample with minor stroke. We determine that the racing simulator is tolerated well in subjects with a minor stroke. There were correlations between research and racing simulator outcomes with psychometric tests associated with driving performance, such as the Trails Making Test Part A, Snellgrove Maze Task, and the Motricity Index. We found correlations between measures of driving speed on a complex research simulator scenario and racing simulator lap time and maximum tires off track. Finally, we present two models, using outcomes from either the research or racing simulator, predicting road test failure as linked to a previously published fitness-to-drive calculator that uses psychometric screening

    Surface charge of polymer coated SPIONs influences the serum protein adsorption, colloidal stability and subsequent cell interaction in vitro

    Get PDF
    It is known that the nanoparticle–cell interaction strongly depends on the physicochemical properties of the investigated particles. In addition, medium density and viscosity influence the colloidal behaviour of nanoparticles. Here, we show how nanoparticle–protein interactions are related to the particular physicochemical characteristics of the particles, such as their colloidal stability, and how this significantly influences the subsequent nanoparticle–cell interaction in vitro. Therefore, different surface charged superparamagnetic iron oxide nanoparticles were synthesized and characterized. Similar adsorbed protein profiles were identified following incubation in supplemented cell culture media, although cellular uptake varied significantly between the different particles. However, positively charged nanoparticles displayed a significantly lower colloidal stability than neutral and negatively charged particles while showing higher non-sedimentation driven cell-internalization in vitro without any significant cytotoxic effects. The results of this study strongly indicate therefore that an understanding of the aggregation state of NPs in biological fluids is crucial in regards to their biological interaction(s)

    The Australasian Resuscitation In Sepsis Evaluation : fluids or vasopressors in emergency department sepsis (ARISE FLUIDS), a multi-centre observational study describing current practice in Australia and New Zealand

    Get PDF
    Objectives: To describe haemodynamic resuscitation practices in ED patients with suspected sepsis and hypotension. Methods: This was a prospective, multicentre, observational study conducted in 70 hospitals in Australia and New Zealand between September 2018 and January 2019. Consecutive adults presenting to the ED during a 30-day period at each site, with suspected sepsis and hypotension (systolic blood pressure <100 mmHg) despite at least 1000 mL fluid resuscitation, were eligible. Data included baseline demographics, clinical and laboratory variables and intravenous fluid volume administered, vasopressor administration at baseline and 6- and 24-h post-enrolment, time to antimicrobial administration, intensive care admission, organ support and in-hospital mortality. Results: A total of 4477 patients were screened and 591 were included with a mean (standard deviation) age of 62 (19) years, Acute Physiology and Chronic Health Evaluation II score 15.2 (6.6) and a median (interquartile range) systolic blood pressure of 94 mmHg (87–100). Median time to first intravenous antimicrobials was 77 min (42–148). A vasopressor infusion was commenced within 24 h in 177 (30.2%) patients, with noradrenaline the most frequently used (n = 138, 78%). A median of 2000 mL (1500–3000) of intravenous fluids was administered prior to commencing vasopressors. The total volume of fluid administered from pre-enrolment to 24 h was 4200 mL (3000–5661), with a range from 1000 to 12 200 mL. Two hundred and eighteen patients (37.1%) were admitted to an intensive care unit. Overall in-hospital mortality was 6.2% (95% confidence interval 4.4–8.5%). Conclusion: Current resuscitation practice in patients with sepsis and hypotension varies widely and occupies the spectrum between a restricted volume/earlier vasopressor and liberal fluid/later vasopressor strategy

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Ventilatory compensation for changes in posture after human heart-lung transplantation

    No full text
    We have studied the contribution of vagal pulmunary receptors to the stability of breathing during postural changes in humans. Quiet breathing was quantified in the seated and the supine postures in 10 patients with chronic pulmunary denervation due to heart-lung transplantation and 10 age and sex matched normal controls. In the vast majority of patients and normal subjects frequency histograms for tidal volume and mean inspiratoru flow rate were virtually superimposed seated and supine. There were no significant differences in the mean levels of respiratory variables between postures in either group (except for mean inspiratory flow rate in the patients which was slightly greater seated than supine). Experiments performed on a tilt table in two additional patients showed that the ventilatory response to postural changes was immediate. In addition, the response was maintained after blockade of intact tracheal stretch receptors with aerosolized lidocaine. These results indicate that adequate ventilatory compensation during postural changes does not depend on vagal afferent information arising in intrapulmonary or tracheal airway stretch receptors. The appropriate receptors may be diaphragmatic Golgi tendon organs. © 1989.SCOPUS: ar.jinfo:eu-repo/semantics/publishe
    corecore