58 research outputs found

    Analyzing power measurements in high‐P2∥ p‐p elastic scattering

    Full text link
    The analyzing power in 28 GeV/c proton/proton elastic scattering was measured at P2∥=5.95 and 6.56 (GeV/c)2 using a polarized proton target and an unpolarized proton beam at the Brookhaven National Laboratory AGS. Results indicate that the analyzing power, A, is rising sharply with P2∥.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87401/2/1123_1.pd

    A review on development and application of plant-based bioflocculants and grafted bioflocculants

    Get PDF
    Flocculation is extensively employed for clarification through sedimentation. Application of eco-friendly plant-based bioflocculants in wastewater treatment has attracted significant attention lately with high removal capability in terms of solids, turbidity, color, and dye. However, moderate flocculating property and short shelf life restrict their development. To enhance the flocculating ability, natural polysaccharides derived from plants are chemically modified by inclusion of synthetic, nonbiodegradable monomers (e.g., acrylamide) onto their backbone to produce grafted bioflocculants. This review is aimed to provide an overview of the development and flocculating efficiencies of plant-based bioflocculants and grafted bioflocculants for the first time. Furthermore, the processing methods, flocculation mechanism, and the current challenges are discussed. All the reported studies about plant-derived bioflocculants are conducted under lab-scale conditions in wastewater treatment. Hence, the possibility to apply natural bioflocculants in food and beverage, mineral, paper and pulp, and oleo-chemical and biodiesel industries is discussed and evaluated

    Multiple Gamma-Ray Detection Capability of a CeBr3 Detector for Gamma Spectroscopy

    No full text
    The newly developed cerium tribromide (CeBr3) detector has reduced intrinsic gamma-ray activity with gamma energy restricted to 1400–2200 keV energy range. This narrower region of background gamma rays allows the CeBr3 detector to detect more than one gamma ray to analyze the gamma-ray spectrum. Use of multiple gamma-ray intensities in elemental analysis instead of a single one improves the accuracy of the estimated results. Multigamma-ray detection capability of a cylindrical 75 mm × 75 mm (diameter × height) CeBr3 detector has been tested by analyzing the chlorine concentration in water samples using eight chlorine prompt gamma rays over 517 to 8578 keV energies utilizing a D-D portable neutron generator-based PGNAA setup and measuring the corresponding minimum detection limit (MDC) of chlorine. The measured MDC of chlorine for gamma rays with 517–8578 keV energies varies from 0.07 ± 0.02 wt% to 0.80 ± 0.24. The best value of MDC was measured to be 0.07 ± 0.02 wt% for 788 keV gamma rays. The experimental results are in good agreement with Monte Carlo calculations. The study has shown excellent detection capabilities of the CeBr3 detector for eight prompt gamma rays over 517–8578 keV energy range without significant background interference
    corecore