17,204 research outputs found

    Source and Sink Strength of Carbon Dioxide, Methane and Distribution of Sulfate in Salt-marsh Soils at the Wadden Sea Coast of Northern Germany

    Get PDF
    A field study was conducted at Schleswig-Holstein of Kiel in Germany to evaluate the factors controlling carbon and sulfate dynamics along a toposequence of coastal salt marsh soils. The soil at the top end of the salt marsh was salic silty to clayic Typic Sulfaquent (Salzrohmarsh) and the bottom end was sandy to silty Haplic Sulfaquent  Ubergangsmischwatt). The mean (depth: 0-100 cm) values of pH andrH were 6.8-6.9; 6.8-7.0 and 17.3-8.1; 15-8.6 for the Typic Sulfaquent (TS) and Haplic Sulfaquent (HS) throughout the year, respectively. The net-emission of CO2 was negative (-14.0 g m-2 yr-1) for the HS but highly positive (857 g m-2 yr-1) for the TS throughout the year. The annual emissions of CH4 were almost 10fold higher in HS (0.3 g m-2 yr-1) than that of the TS (0.03 g m-2 yr-1). The concentrations of CH4 at different seasons showed almost inverse relationships with the concentrations of CO2, varied significantly (p.0.05) with the seasons and depth function, and showed no dependence to temperature. The SO4 contents were observed maximum in the TS than that of HS during all the seasons. There was no noticeable correlation (r=-0.09) between SO4 and CH4 concentrations. Moreover, even CH4 was determined at depths where the SO4concentration was about 1200 mg SO4 L-

    Neutron specific heat in the crust of neutron stars from the nuclear band theory

    Full text link
    The inner crust of neutron stars, formed of a crystal lattice of uclear clusters immersed in a sea of unbound neutrons, may be the nique example of periodic nuclear systems. We have calculated the neutron specific heat in the shallow part of the crust using the band theory of solids with Skyrme nucleon-nucleon interactions. We have also tested the validity of various approximations. We have found that the neutron specific heat is well described by that of a Fermi gas, while the motion of the unbound neutrons is strongly affected by the nuclear lattice. These apparently contradictory results are explained by the particular properties of the neutron Fermi surface

    Duplex PCR assay for the detection of avian adeno virus and chicken anemia virus prevalent in Pakistan

    Get PDF
    Avian Adeno viruses and Chicken Anemia Viruses cause serious economic losses to the poultry industry of Pakistan each year. Timely and efficient diagnosis of the viruses is needed in order to practice prevention and control strategies. In the first part of this study, we investigated broilers, breeder and Layer stocks for morbidity and mortality rates due to AAV and CAV infections and any co-infections by examining signs and symptoms typical of their infestation or post mortem examination. In the second part of the study, we developed a duplex PCR assay for the detection of AAV and CAV which is capable to simultaneously detect both the viral types prevalent in Pakistan with high sensitivity and 100% specificity

    Simulation-based analysis of dynamic voltage restorer with sliding mode controller at optimal voltage for power quality enhancement in distribution system

    Get PDF
    Introduction. Nowadays, power quality issues are of considerable interest to both utilities and end users as they cause significant financial losses to the industrial customers. Due to this, power quality assurance in power distribution systems is very important, when considering commercial and industrial applications. Problem Statement. Unfortunately, sudden faults such as sag, transients, harmonics distortion and notching in the power system create disturbances and affect the load voltages. Out of these, voltage sag and harmonics seriously affect sensitive devices. Harmonics in the power system cause increased heating of equipment and conductors, misfires in variable speed drives, and torque pulsations in motors. Harmonics reduction is considered desirable. Methodology. This paper presents an efficient and robust solution to this problem by using dynamic voltage restorer in series with distribution system. Dynamic voltage restorer is economical and effective solution for protecting sensitive loads from harmonics and sag. Control strategy is adopted with dynamic voltage restorer topology and the performance with the proposed controller is analyzed. Novelty. In this research work modelling, analysis and simulation of dynamic voltage restorer with proportional integral controller and dynamic voltage restorer with sliding-mode controller at optimal voltage is used to improve the dynamic voltage restorer performance by reducing total harmonic distortion. Results. The simulation is performed in MATLAB / Simulink software package and comparative analysis of dynamic voltage restorer with different controllers for distribution system is presented. The proposed scheme successfully reduced percentage total harmonics distortion and voltage sag using dynamic voltage restorer with sliding mode controller at optimal voltage which is found to be 0.38 %.Вступ. Сьогодні питання якості електроенергії викликають значний інтерес як для комунальних підприємств, так і для кінцевих споживачів, оскільки вони завдають значних фінансових втрат промисловим споживачам. У зв’язку з цим забезпечення якості електроенергії в розподільних системах є дуже важливим при розгляді комерційних та промислових застосувань. Постановка задачі. На жаль, раптові несправності, такі як прогини, перехідні процеси, спотворення гармонік і виїмки в енергосистемі створюють збурення та впливають на напругу навантаження. З них провали напруги та гармоніки серйозно впливають на чутливі пристрої. Гармоніки в енергосистемі викликають посилений нагрів обладнання та провідників, пропуски запалювання в приводах із змінною частотою обертання, пульсації крутного моменту в двигунах. Зниження гармонік вважається бажаним. Методологія. У цій статті представлено ефективне та надійне рішення цієї проблеми за допомогою динамічного відновника напруги послідовно з розподільною системою. Динамічний відновник напруги – це економне та ефективне рішення для захисту чутливих навантажень від гармоній та провисань. Прийнято стратегію керування з топологією динамічного відновника напруги та проаналізовано ефективність при використанні запропонованого контролера. Новизна. У цій дослідницькій роботі використовується моделювання, аналіз та чисельне дослідження динамічного відновника напруги з пропорційним інтегральним контролером та динамічного відновника напруги з регулятором ковзного режиму при оптимальній напрузі для підвищення ефективності динамічного відновника напруги за рахунок зменшення сумарних гармонійних спотворень. Результати. Моделювання виконано в програмному комплексі MATLAB / Simulink та представлено порівняльний аналіз динамічного відновника напруги з різними контролерами для розподільчої системи. Запропонована схема успішно зменшила відсоток спотворення сумарних гармонік і провалів напруги за допомогою динамічного відновника напруги з регулятором ковзного режиму при оптимальній напрузі, який становить 0,38 %

    Modeling the lasing spectra of InAs/InP Quantum dash lasers

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/98746/1/ApplPhysLett_98_101105.pd
    corecore