19 research outputs found

    Flexible bronchoscopy contribution in the approach of diagnosis and treatment of children’s respiratory diseases: the experience of a unique pediatric unit in Tunisia

    Get PDF
    Objective: Our study aimed at assessing the role of flexible bronchoscopy (FB) in improving diagnosis and management of children’s respiratory conditions in the pediatric unit of FB, newly created and unique in Tunisia.Methods: Retrospective study including all the FB achieved in our pediatric unit from 2009 to 2014.Results: We performed 365 FB in 333 patients aged 46 months on average (1 month - 15 years), often under conscious anesthesia (81.6%). FB was performed for diagnostic purposes in 341 cases and for therapeutic purposes in 24 cases. Eight anatomical abnormalities were revealed in 22 patients. An intraluminal bronchial obstruction was found in 71 FB, mainly due to a foreign body (n=36). A vascular anomaly was responsible for nine cases out of 17 extraluminal obstructions. Airways malacia was observed in 60 FB. Bronchoalveolar lavage was performed in 196 cases. It was determinant in 43.9% of the cases. FB was of great diagnostic value in 74.8% of the cases. It influenced the management of the patients in 58% of the cases. The FB for therapeutic purposes was beneficial in all cases. Few complications occurred (5.5%).Conclusion: FB is a safe tool providing precious diagnostic and/or therapeutic help for the clinician.Keywords: Flexible bronchoscopy, child, bronchoalveolar lavage, foreign body aspiration, pulmonary alveolar proteinosi

    Flexible bronchoscopy contribution in the approach of diagnosis and treatment of children\u2019s respiratory diseases: the experience of a unique pediatric unit in Tunisia.

    Get PDF
    Objective: Our study aimed at assessing the role of flexible bronchoscopy (FB) in improving diagnosis and management of children\u2019s respiratory conditions in the pediatric unit of FB, newly created and unique in Tunisia. Methods: Retrospective study including all the FB achieved in our pediatric unit from 2009 to 2014. Results: We performed 365 FB in 333 patients aged 46 months on average (1 month - 15 years), often under conscious anesthesia (81.6%). FB was performed for diagnostic purposes in 341 cases and for therapeutic purposes in 24 cases. Eight anatomical abnormalities were revealed in 22 patients. An intraluminal bronchial obstruction was found in 71 FB, mainly due to a foreign body (n=36). A vascular anomaly was responsible for nine cases out of 17 extraluminal obstructions. Airways malacia was observed in 60 FB. Bronchoalveolar lavage was performed in 196 cases. It was determinant in 43.9% of the cases. FB was of great diagnostic value in 74.8% of the cases. It influenced the management of the patients in 58% of the cases. The FB for therapeutic purposes was beneficial in all cases. Few complications occurred (5.5%). Conclusion: FB is a safe tool providing precious diagnostic and/or therapeutic help for the clinician. Keywords

    Long-term outcome of Tunisian children with primary ciliary dyskinesia confirmed by transmission electron microscopy.

    Get PDF
    Background: Primary ciliary dyskinesia (PCD) is rare. Its diagnosis requires experienced specialists and expensive infrastructure. Its prognosis is variable. Objective: To study the long-term outcome of PCD in Tunisian children with ciliary ultra-structure defects detected by electron microscope. Methods: Covering a period of 20 years (1996-2015), this retrospective study included all patients with definite PCD (outer dynein arms (DA) defects and/or situs inversus) and presumed PCD (other ciliary ultra-structure defects). The clinical data and the investigations made were registered at diagnosis and during the follow-up. Results: Patients with a definite PCD (G1, n=7) were diagnosed earlier compared to those with a presumed PCD (G2, n=13) (2.5 vs. 9.3 years on average). At diagnosis, bronchiectasis was more frequent in G1 (3/7 vs. 4/13). The inner DA loss was constant in G1 and predominant in G2. The treatment adhesion was more often irregular in G2 (2/7 vs. 8/13). During a mean follow-up of 11 years, G1 showed less severe outcome (clubbing (0 vs. 3), bronchiectasis (3 vs. 11; more expanded in G2), proximal and distal airway obstruction (0/3 vs. 5/7), lobectomy (0 vs. 2), and death (0 vs. 2)). Conclusion: Precocious diagnosis and regular treatment may enhance the PCD prognosis

    Application of the active inductor circuit (AI) based band pass Filter (BPF)

    Full text link
    A novel active inductor approach, which can improve the quality-factor, was presented in this report. A current reuse active inductor circuit topology was proposed, which can substantially improve its equivalent inductance. This active inductor was implemented by using a 0.13um- CMOS technology, which gives a maximum quality-factor of 1.45 with a 40 nH at 2.259GHz. An optimized differential topology of an RF active filter and its performances are presented. It make use of negative resistance and fully differential in order to independently tune the central frequency and the quality factor with a minimum power consumption of 1.98 mW. The principle seems to be sufficiently general to be used for other active filters single–ended or differential topologies based on simulated inductors

    Full title: peripheral venous catheter complications in children: predisposing factors in a multicenter prospective cohort study

    No full text
    Abstract Background Peripheral venous catheterization (PVC) is frequently used in children. This procedure is not free from potential complications. Our purpose was to identify the types and incidences of PVC complications in children and their predisposing factors in a developing country. Methods We conducted a prospective observational multicenter study in five pediatric and pediatric surgery departments over a period of 2 months. Two hundred fifteen PVC procedures were conducted in 98 children. The times of insertion and removal and the reasons for termination were noted, and the lifespan was calculated. Descriptive data were expressed as percentages, means, standard deviations, medians and interquartile ranges. The Chi2 test or the Fisher test, with hazard ratios and 95% confidence intervals (CI95%), as well as Student’s t test or the Mann-Whitney U test were used to compare categorical and quantitative variables, respectively, in groups with and without complications. The Spearman test was used to determine correlations between the lifespan and the quantitative variables. The Kruskal Wallis test was used to test for differences in the median lifespan within 3 or more subgroups of a variable. Linear regression and logistic binary regression were used for multivariate analysis. A p-value <0.05 was considered significant. Results The mean lifespan was 68.82 ± 35.71 h. A local complication occurred in 111 PIVC (51.9%) cases. The risk factors identified were a small catheter gauge (24-gauge) (p = 0.023), the use of a volume-controlled burette (p = 0.036), a longer duration of intravenous therapy (p < 0.001), a medical diagnosis of respiratory or infectious disease (p = 0.047), the use of antibiotics (p = 0.005), including cefotaxime (p = 0.024) and vancomycin (p = 0.031), and the use of proton pump inhibitors (p = 0.004).The lifespan of the catheters was reduced with the occurrence of a complication (p < 0.001), including the use of 24-gauge catheters (p = 0.001), the use of an electronic pump or syringe(p = 0.036) and a higher rank of the intravenous device in each patient (p = 0.010). Conclusions PVC complications were frequent in our pediatric departments and are often associated with misuse of the device. These results could engender awareness among both doctors and nurses regarding the need for rationalization of the use of PVC and better adherence to the recommendations for the use of each drug and each administration method
    corecore