8,831 research outputs found

    Performance of the OPAL Si-W luminometer at LEP I-II

    Full text link
    A pair of compact Silicon-Tungsten calorimeters was operated in the OPAL experiment at LEP to measure the integrated luminosity from detection of Bhabha electrons scattered at angles between 25 and 58 mrad from the beam line. In the eight years from 1993 to 2000 the detector worked first at the Z mass peak and then at center of mass energies up to 209 GeV. The fine radial and longitudinal segmentation (2.5mm x 1X0) allowed the radial position of electron and photon showers to be measured with a resolution of 130-170 microns and a residual radial bias as small as 7 microns. Reducing the bias in the definition of the inner acceptance radius was the key element in obtaining an experimental systematic error on the integrated luminosity of only 3.4 10^-4. The performance of the detector at both LEP-I and LEP-II is reviewed. Energy resolution, sensitivity to overlapping electromagnetic showers and sensitivity to minimum ionizing particles are discussed.Comment: 9 pages, 7 figures, 10th International Conference on Calorimetry in High Energy Physics. http://3w.hep.caltech.edu/calor02

    Precision of the calibration of the AXAF engineering test article (VETA) mirrors

    Get PDF
    Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly

    Nonlocal Gravity: Modified Poisson's Equation

    Full text link
    The recent nonlocal generalization of Einstein's theory of gravitation reduces in the Newtonian regime to a nonlocal and nonlinear modification of Poisson's equation of Newtonian gravity. The nonlocally modified Poisson equation implies that nonlocality can simulate dark matter. Observational data regarding dark matter provide limited information about the functional form of the reciprocal kernel, from which the original nonlocal kernel of the theory must be determined. We study this inverse problem of nonlocal gravity in the linear domain, where the applicability of the Fourier transform method is critically examined and the conditions for the existence of the nonlocal kernel are discussed. This approach is illustrated via simple explicit examples for which the kernels are numerically evaluated. We then turn to a general discussion of the modified Poisson equation and present a formal solution of this equation via a successive approximation scheme. The treatment is specialized to the gravitational potential of a point mass, where in the linear regime we recover the Tohline-Kuhn approach to modified gravity.Comment: 27 pages, 4 figures; v2: minor improvements, accepted for publication in J. Math. Phy

    A Comparison of Skyline Harvesting Costs for Alternative Commercial Thinning Prescriptions

    Get PDF
    Harvesting production and costs were examined for three alternative silvicultural prescriptions at two sites in the Coast Range of Oregon. Thirty-three-year-old Douglas fir stands were commercially thinned to residual densities of 247,148, and 74 trees per hectare (tph) [100,60, and 30 trees per acre (tpa), respectively]. Detailed time studies were conducted on manual felling and uphill skyline yarding with small yarders. Separate regression equations were developed to predict delay-free felling cycle time and delay-free yarding cycle time. The 74 tph [30 tpa] treatment had the highest production rate and was the least costly to harvest. Total harvesting costs of the other two treatments averaged from 6.0% (148 tph [60 tpa]) to 12.3% (247 tph [100 tpa]) more than the 74 tph [30 tpa] treatment

    Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

    Get PDF
    The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response

    VETA-I x ray test analysis

    Get PDF
    This interim report presents some definitive results from our analysis of the VETA-I x-ray testing data. It also provides a description of the hardware and software used in the conduct of the VETA-I x-ray test program performed at the MSFC x-ray Calibration Facility (XRCF). These test results also serve to supply data and information to include in the TRW final report required by DPD 692, DR XC04. To provide an authoritative compendium of results, we have taken nine papers as published in the SPIE Symposium, 'Grazing Incidence X-ray/EUV Optics for Astronomy and Projection Lithography' and have reproduced them as the content of this report

    A Seat at the Table: Minority Representation and County Governing Boards

    Get PDF
    This study focuses on minority representation on county governing boards to determine the extent of minority representation, and then to provide explanation for the exiting patterns in its representation. The dependent variable used in this paper is a count variable employing a Zero-Inflated Negative Binomial model. The results indicate that minority populations, counties located in the South, partisan elections, the size of county governing boards and urban counties have positive effects on increased minority representation, while at-large voting districts have a negative effect. Furthermore, it advances the need for greater research on county governing boards, county governments in general and a new agenda for the future study of minority representation on local governing bodies

    Stability of sub-surface oxygen at Rh(111)

    Full text link
    Using density-functional theory (DFT) we investigate the incorporation of oxygen directly below the Rh(111) surface. We show that oxygen incorporation will only commence after nearly completion of a dense O adlayer (\theta_tot = 1.0 monolayer) with O in the fcc on-surface sites. The experimentally suggested octahedral sub-surface site occupancy, inducing a site-switch of the on-surface species from fcc to hcp sites, is indeed found to be a rather low energy structure. Our results indicate that at even higher coverages oxygen incorporation is followed by oxygen agglomeration in two-dimensional sub-surface islands directly below the first metal layer. Inside these islands, the metastable hcp/octahedral (on-surface/sub-surface) site combination will undergo a barrierless displacement, introducing a stacking fault of the first metal layer with respect to the underlying substrate and leading to a stable fcc/tetrahedral site occupation. We suggest that these elementary steps, namely, oxygen incorporation, aggregation into sub-surface islands and destabilization of the metal surface may be more general and precede the formation of a surface oxide at close-packed late transition metal surfaces.Comment: 9 pages including 9 figure files. Submitted to Phys. Rev. B. Related publications can be found at http://www.fhi-berlin.mpg.de/th/paper.htm

    The x ray reflectivity of the AXAF VETA-I optics

    Get PDF
    The x-ray reflectivity of the VETA-I optic, the outermost shell of the AXAF x-ray telescope, with a bare Zerodur surface, is measured and compared with theoretical predictions. Measurements made at energies of 0.28, 0.9, 1.5, 2.1, and 2.3 keV are compared with predictions based on ray trace calculations. The data were obtained at the x-ray calibrations facility at Marshall Space Flight Center with an electron impact x-ray source located 528 m from the grazing incidence mirror. The source used photoelectric absorption filters to eliminate bremsstrahlung continuum. The mirror has a diameter of 1.2 m and a focal length of 10 m. The incident and reflected x-ray flux are detected using two proportional counters, one located in the incident beam of x-rays at the entrance aperture of the VETA-I, and the other in the focal plane behind an aperture of variable size. Results on the variation of the reflectivity with energy as well as the absolute value of the reflectivity are presented. We also present a synchrotron reflectivity measurement with high energy resolution over the range 0.26 to 1.8 keV on a flat Zerodur sample, done at NSLS. We present evidence for contamination of the flat by a thin layer of carbon on the surface, and the possibility of alteration of the surface composition of the VETA-I mirror perhaps by the polishing technique. The overall agreement between the measured and calculated effective area of VETA-I is between 2.6 percent and 10 percent, depending on which model for the surface composition is adopted. Measurements at individual energies deviate from the best-fitting calculation to 0.3 to 0.8 percent, averaging 0.6 percent at energies below the high energy cutoff of the mirror reflectivity, and are as high as 20.7 percent at the cutoff. We also discuss the approach to the final preflight calibration of the full AXAF flight mirror

    VETA-1 x ray detection system

    Get PDF
    The alignment and X-ray imaging performance of the Advanced X-ray Astrophysics Facility (AXAF) Verification Engineering Test Article-I (VETA-I) was measured by the VETA-I X-Ray Detection System (VXDS). The VXDS was based on the X-ray detection system utilized in the AXAF Technology Mirror Assembly (TMA) program, upgraded to meet the more stringent requirements of the VETA-I test program. The VXDS includes two types of X-ray detectors: (1) a High Resolution Imager (HRI) which provides X-ray imaging capabilities, and (2) sealed and flow proportional counters which, in conjunction with apertures of various types and precision translation stages, provide the most accurate measurement of VETA-I performance. Herein we give an overview of the VXDS hardware including X-ray detectors, translation stages, apertures, proportional counters and flow counter gas supply system and associated electronics. We also describe the installation of the VXDS into the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF). We discuss in detail the design and performance of those elements of the VXDS which have not been discussed elsewhere; translation systems, flow counter gas supply system, apertures and thermal monitoring system
    corecore