29 research outputs found
Native T1 values identify myocardial changes and stratify disease severity in patients with Duchenne muscular dystrophy
BACKGROUND: Duchenne muscular dystrophy (DMD) is an X-linked, inherited disorder causing dilated cardiomyopathy with variable onset and progression. Currently we lack objective markers of the effect of therapies targeted towards preventing progression of subclinical cardiac disease. Thus, our aim was to compare the ability of native T1 and extracellular volume (ECV) measurements to differentiate risk of myocardial disease in DMD and controls. METHODS: Twenty boys with DMD and 16 age/gender-matched controls without history predisposing to cardiac fibrosis, but with a clinical indication for cardiovascular magnetic resonance (CMR) evaluation, underwent CMR with contrast. Data points collected include left ventricular ejection fraction (LVEF), left ventricular mass, and presence of late gadolinium enhancement (LGE). Native T1, and ECV regional mapping were obtained using both a modified Look-Locker (MOLLI) and saturation recovery single shot sequence (SASHA) on a 1.5T scanner. Using ordinal logistic regression models, controlling for age and LVEF, LGE-free septal we evaluated the ability native T1 and ECV assessments to differentiate levels of cardiomyopathy. RESULTS: Twenty DMD subjects aged 14.4 ± 4 years had an LVEF of 56.3 ± 7.4 %; 12/20 had LGE, all confined to the lateral wall. Sixteen controls aged 16.1 ± 2.2 years had an LVEF 60.4 ± 5.1 % and no LGE. Native T1 and ECV values were significantly higher in the DMD group (p < 0.05) with both MOLLI and SASHA imaging techniques. Native T1 demonstrated a 50 % increase in the ability to predict disease state (control, DMD without fibrosis, DMD with fibrosis). ECV demonstrated only the ability to predict presence of LGE, but could not distinguish between controls and DMD without fibrosis. CONCLUSIONS: LGE-spared regions of boys with DMD have significantly different native T1 and ECV values compared to controls. Native T1 measurements can identify early changes in DMD patients without the presence of LGE and help predict disease severity more effectively than ECV. Native T1 may be a novel outcome measure for early cardiac therapies in DMD and other cardiomyopathies
Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects
Background: Non-invasive assessment of myocardial ischaemia is a cornerstone of the diagnosis of coronary artery disease. Measurement of myocardial blood flow (MBF) using positron emission tomography (PET) is the current reference standard for non-invasive quantification of myocardial ischaemia. Dynamic myocardial perfusion cardiovascular magnetic resonance (CMR) offers an alternative to PET and a recently developed method with automated inline perfusion mapping has shown good correlation of MBF values between CMR and PET. This study assessed the repeatability of myocardial perfusion mapping by CMR in healthy subjects.
Methods: Forty-two healthy subjects were recruited and underwent adenosine stress and rest perfusion CMR on two visits. Scans were repeated with a minimum interval of 7 days. Intrastudy rest and stress MBF repeatability were assessed with a 15-min interval between acquisitions. Interstudy rest and stress MBF and myocardial perfusion reserve (MPR) were measured for global myocardium and regionally for coronary territories and slices.
Results: There was no significant difference in intrastudy repeated global rest MBF (0.65 ± 0.13 ml/g/min vs 0.62 ± 0.12 ml/g/min, p = 0.24, repeatability coefficient (RC) =24%) or stress (2.89 ± 0.56 ml/g/min vs 2.83 ± 0.64 ml/g/min, p = 0.41, RC = 29%) MBF. No significant difference was seen in interstudy repeatability for global rest MBF (0.64 ± 0.13 ml/g/min vs 0.64 ± 0.15 ml/g/min, p = 0.80, RC = 32%), stress MBF (2.71 ± 0.61 ml/g/min vs 2.55 ± 0.57 ml/g/min, p = 0.12, RC = 33%) or MPR (4.24 ± 0.69 vs 3.73 ± 0.76, p = 0.25, RC = 36%). Regional repeatability was good for stress (RC = 30–37%) and rest MBF (RC = 32–36%) but poorer for MPR (RC = 35–43%). Within subject coefficient of variation was 8% for rest and 11% for stress within the same study, and 11% for rest and 12% for stress between studies.
Conclusions: Fully automated, inline, myocardial perfusion mapping by CMR shows good repeatability that is similar to the published PET literature. Both rest and stress MBF show better repeatability than MPR, particularly in regional analysis
Incremental grouping of image elements in vision
One important task for the visual system is to group image elements that belong to an object and to segregate them from other objects and the background. We here present an incremental grouping theory (IGT) that addresses the role of object-based attention in perceptual grouping at a psychological level and, at the same time, outlines the mechanisms for grouping at the neurophysiological level. The IGT proposes that there are two processes for perceptual grouping. The first process is base grouping and relies on neurons that are tuned to feature conjunctions. Base grouping is fast and occurs in parallel across the visual scene, but not all possible feature conjunctions can be coded as base groupings. If there are no neurons tuned to the relevant feature conjunctions, a second process called incremental grouping comes into play. Incremental grouping is a time-consuming and capacity-limited process that requires the gradual spread of enhanced neuronal activity across the representation of an object in the visual cortex. The spread of enhanced neuronal activity corresponds to the labeling of image elements with object-based attention
Overview of DIII-D off-axis neutral beam project
DIII-D has four neutral beamlines (NB). Each of these beamlines has two ion sources, each of which injects up to 2.5 MW for 3 s. These beamlines intersect the vacuum vessel at an angle of 19.5 deg off from radial, enabling current drive in the same direction as the plasma current (co-injection). In 2004, one of these beamlines (210 deg) was rotated to provide counter-injection (opposite of plasma current). A different beamline (150 deg) has been modified to have the capability to provide off-axis neutral beam current drive. The goal of the off-axis injection is to have the center of the ion sources aimed at a position 40 cm below the geometric center of the plasma. To achieve this off-axis injection, the beamline requires a mechanical lifting system that can elevate the beamline up to 16.5 deg from horizontal. The beamline also requires more strongly vertically focused ion sources (in order to pass the beam through a reduced effective aperture) as well as modified internal components. Additionally, the design of the new internal components incorporated modifications to allow for the doubling of ion source pulse lengths without the need for active cooling. This paper discusses the various beamline system design requirements for off-axis injection, as well as the results from the actual commissioning of the beamline. Overviews of the design and performance of mechanical lifting system (hydraulics and controls), focused ion sources, flexible beamline support systems (vacuum, cryogenic, power and water cooling), and internal beamline collimators are included. Additionally, the in-vessel monitoring and shine-through protection requirements are discussed. The actual data obtained during beamline commissioning and during normal physics operations is also presented. © 2011 IEEE
Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification
Abstract Background Quantification of myocardial blood flow requires knowledge of the amount of contrast agent in the myocardial tissue and the arterial input function (AIF) driving the delivery of this contrast agent. Accurate quantification is challenged by the lack of linearity between the measured signal and contrast agent concentration. This work characterizes sources of non-linearity and presents a systematic approach to accurate measurements of contrast agent concentration in both blood and myocardium. Methods A dual sequence approach with separate pulse sequences for AIF and myocardial tissue allowed separate optimization of parameters for blood and myocardium. A systems approach to the overall design was taken to achieve linearity between signal and contrast agent concentration. Conversion of signal intensity values to contrast agent concentration was achieved through a combination of surface coil sensitivity correction, Bloch simulation based look-up table correction, and in the case of the AIF measurement, correction of T2* losses. Validation of signal correction was performed in phantoms, and values for peak AIF concentration and myocardial flow are provided for 29 normal subjects for rest and adenosine stress. Results For phantoms, the measured fits were within 5% for both AIF and myocardium. In healthy volunteers the peak [Gd] was 3.5 ± 1.2 for stress and 4.4 ± 1.2 mmol/L for rest. The T2* in the left ventricle blood pool at peak AIF was approximately 10 ms. The peak-to-valley ratio was 5.6 for the raw signal intensities without correction, and was 8.3 for the look-up-table (LUT) corrected AIF which represents approximately 48% correction. Without T2* correction the myocardial blood flow estimates are overestimated by approximately 10%. The signal-to-noise ratio of the myocardial signal at peak enhancement (1.5 T) was 17.7 ± 6.6 at stress and the peak [Gd] was 0.49 ± 0.15 mmol/L. The estimated perfusion flow was 3.9 ± 0.38 and 1.03 ± 0.19 ml/min/g using the BTEX model and 3.4 ± 0.39 and 0.95 ± 0.16 using a Fermi model, for stress and rest, respectively. Conclusions A dual sequence for myocardial perfusion cardiovascular magnetic resonance and AIF measurement has been optimized for quantification of myocardial blood flow. A validation in phantoms was performed to confirm that the signal conversion to gadolinium concentration was linear. The proposed sequence was integrated with a fully automatic in-line solution for pixel-wise mapping of myocardial blood flow and evaluated in adenosine stress and rest studies on N = 29 normal healthy subjects. Reliable perfusion mapping was demonstrated and produced estimates with low variability
An optimization of beta in the DIII-D tokamak
Accurate equilibrium reconstruction and detailed stability analysis of a strongly shaped, double-null, β =11% discharge shows that the plasma core is in the second stable regime to ideal ballooning modes. The equilibrium reconstruction using all the available data (coil currents, poloidal magnetic loops, motional Stark effect data, the kinetic pressure profile, the magnetic axis location, and the location of the two q=1 surfaces) shows a region of negative magnetic shear near the magnetic axis, an outer positive shear region, and a low shear region connecting the two. The inner negative shear region allows a large positive shear region near the boundary, even at low q (q =2.6), permitting a large outer region pressure gradient to be first regime stable. The inner region is in the second stable regime, consistent with the observed axial beta [β (0)=44%]. In the low shear region p′ vanishes, consistent with Mercier stability. This is one way to extend the ballooning limit in shaped plasmas while maintaining stability against external kinks. The n=1 analysis shows that the plasma is unstable to an ideal internal mode, consistent with the experimental observations of a saturated internal m/n=l/l mode. The core plasma pressure, not being limited by ballooning stability, appears to be reaching a local equilibrium limit at the magnetic axis. © 1992 American Institute of Physics. T 95