1,355 research outputs found

    Stability study and time resolution measurement of Straw Tube detectors

    Full text link
    Straw tube detectors are single wire proportional counters that are widely used as a tracking device. We have carried out R&\&D with a straw tube detector prototype. The motivation of this work is to study the stability of the performance in terms of gain and energy resolution of the straw tube detectors under high rate radiation. Two different methods are incorporated to perform this study. The gain and energy resolution of the detector are studied along with its variation with ambient temperature and pressure. X-ray from a radioactive source is used to irradiate the detector and the same source is also used to monitor the energy spectra simultaneously for calculation of gain. Variation of the gain and energy resolution of the straw tube detector under X-ray irradiation in Ar/CO2_2 gas mixture is discussed in this article. We have also estimated the time resolution of the straw tube detectors that can be best achieved with cosmic rays as trigger for the same gas mixture. The details of the measurement process and the experimental results are presented in this article

    Search for Axionlike and Scalar Particles with the NA64 Experiment

    Get PDF
    We carried out a model-independent search for light scalar (s) and pseudoscalar axionlike (a) particles that couple to two photons by using the high-energy CERN SPS H4 electron beam. The new particles, if they exist, could be produced through the Primakoff effect in interactions of hard bremsstrahlung photons generated by 100 GeV electrons in the NA64 active dump with virtual photons provided by the nuclei of the dump. The a(s) would penetrate the downstream HCAL module, serving as shielding, and would be observed either through their a(s)→γγa(s)\to\gamma \gamma decay in the rest of the HCAL detector or as events with large missing energy if the a(s) decays downstream of the HCAL. This method allows for the probing the a(s) parameter space, including those from generic axion models, inaccessible to previous experiments. No evidence of such processes has been found from the analysis of the data corresponding to 2.84×10112.84\times10^{11} electrons on target allowing to set new limits on the a(s)γγa(s)\gamma\gamma-coupling strength for a(s) masses below 55 MeV.Comment: This publication is dedicated to the memory of our colleague Danila Tlisov. 7 pages, 5 figures, revised version accepted for publication in Phys. Rev. Let

    Measurement of the K+→Ό+ÎœÎŒÎłK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} decay form factors in the OKA experiment

    Full text link
    A precise measurement of the vector and axial-vector form factors difference FV−FAF_V-F_A in the K+→Ό+ÎœÎŒÎłK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} decay is presented. About 95K events of K+→Ό+ÎœÎŒÎłK^+\rightarrow{\mu^+}{\nu_{\mu}}{\gamma} are selected in the OKA experiment. The result is FV−FA=0.134±0.021(stat)±0.027(syst)F_V-F_A=0.134\pm0.021(stat)\pm0.027(syst). Both errors are smaller than in the previous FV−FAF_V-F_A measurements.Comment: 9 pages, 8 figure

    Multi-layer scintillation detector for the MOON double beta decay experiment: Scintillation photon responses studied by a prototype detector MOON-1

    Get PDF
    An ensemble of multi-layer scintillators is discussed as an option of the high-sensitivity detector Mo Observatory Of Neutrinos (MOON) for spectroscopic measurements of neutrino-less double beta decays. A prototype detector MOON-1, which consists of 6 layer plastic-scintillator plates, was built to study the sensitivity of the MOON-type detector. The scintillation photon collection and the energy resolution, which are key elements for the high-sensitivity experiments, are found to be 1835+/-30 photo-electrons for 976 keV electrons and sigma = 2.9+/-0.1% (dE/E = 6.8+/-0.3 % in FWHM) at the Qbb ~ 3 MeV region, respectively. The multi-layer plastic-scintillator structure with good energy resolution as well as good background suppression of beta-gamma rays is crucial for the MOON-type detector to achieve the inverted hierarchy neutrino mass sensitivity.Comment: 8 pages, 16 figures, submitted to Nucl.Instrum.Met

    Prospects for K+→π+ΜΜˉK^+ \to \pi^+ \nu \bar{ \nu } at CERN in NA62

    Full text link
    The NA62 experiment will begin taking data in 2015. Its primary purpose is a 10% measurement of the branching ratio of the ultrarare kaon decay K+→π+ΜΜˉK^+ \to \pi^+ \nu \bar{ \nu }, using the decay in flight of kaons in an unseparated beam with momentum 75 GeV/c.The detector and analysis technique are described here.Comment: 8 pages for proceedings of 50 Years of CP

    A precision measurement of direct CP violation in the decay of neutral kaons into two pions

    Get PDF
    The direct CP violation parameter Re(epsilon'/epsilon) has been measured from the decay rates of neutral kaons into two pions using the NA48 detector at the CERN SPS. The 2001 running period was devoted to collecting additional data under varied conditions compared to earlier years (1997-99). The new data yield the result: Re(epsilon'/epsilon) = (13.7 +/- 3.1) times 10^{-4}. Combining this result with that published from the 1997, 98 and 99 data, an overall value of Re(epsilon'/epsilon) = (14.7 +/- 2.2) times 10^{-4} is obtained from the NA48 experiment.Comment: 19 pages, 5 figures, to be published in Physics Letters
    • 