992 research outputs found

    Bifurcated polarization rotation in bismuth-based piezoelectrics

    Get PDF
    ABO3 perovskite-type solid solutions display a large variety of structural and physical properties, which can be tuned by chemical composition or external parameters such as temperature, pressure, strain, electric, or magnetic fields. Some solid solutions show remarkably enhanced physical properties including colossal magnetoresistance or giant piezoelectricity. It has been recognized that structural distortions, competing on the local level, are key to understanding and tuning these remarkable properties, yet, it remains a challenge to experimentally observe such local structural details. Here, from neutron pair-distribution analysis, a temperature-dependent 3D atomic-level model of the lead-free piezoelectric perovskite Na0.5Bi0.5TiO3 (NBT) is reported. The statistical analysis of this model shows how local distortions compete, how this competition develops with temperature, and, in particular, how different polar displacements of Bi3+ cations coexist as a bifurcated polarization, highlighting the interest of Bi-based materials in the search for new lead-free piezoelectrics

    Structural and Magnetic Investigations of Single-Crystals of the Neodymium Zirconate Pyrochlore, Nd2Zr2O7

    Get PDF
    We report structural and magnetic properties studies of large high quality single-crystals of the frustrated magnet, Nd2_2Zr2_2O7_7. Powder x-ray diffraction analysis confirms that Nd2_2Zr2_2O7_7 adopts the pyrochlore structure. Room-temperature x-ray diffraction and time-of-flight neutron scattering experiments show that the crystals are stoichiometric in composition with no measurable site disorder. The temperature dependence of the magnetic susceptibility shows no magnetic ordering at temperatures down to 0.5 K. Fits to the magnetic susceptibility data using a Curie-Weiss law reveal a ferromagnetic coupling between the Nd moments. Magnetization versus field measurements show a local Ising anisotropy along the axes of the Nd3+^{3+} ions in the ground state. Specific heat versus temperature measurements in zero applied magnetic field indicate the presence of a thermal anomaly below T7T\sim7 K, but no evidence of magnetic ordering is observed down to 0.5 K. The experimental temperature dependence of the single-crystal bulk dc susceptibility and isothermal magnetization are analyzed using crystal field theory and the crystal field parameters and exchange coupling constants determined.Comment: 10 pages, 6 figures, 4 tables. Accepted for publication in Physical Review

    Operation Moshtarak and the manufacture of credible, “heroic” warfare

    Get PDF
    Richard Lance Keeble argues that Fleet Street’s coverage of the Afghan conflict has served largely to promote the interests of the military/industrial/media complex – and marginalise the views of the public who have consistently appealed in polls for the troops to be brought back hom

    First-Order Reorientation of the Flux-Line Lattice in CaAlSi

    Full text link
    The flux line lattice in CaAlSi has been studied by small angle neutron scattering. A well defined hexagonal flux line lattice is seen just above Hc1 in an applied field of only 54 Oe. A 30 degree reorientation of this vortex lattice has been observed in a very low field of 200 Oe. This reorientation transition appears to be of first-order and could be explained by non-local effects. The magnetic field dependence of the form factor is well described by a single penetration depth of 1496(1) angstroms and a single coherence length of 307(1) angstroms at 2 K. At 1.5 K the penetration depth anisotropy is 2.7(1) with the field applied perpendicular to the c axis and agrees with the coherence length anisotropy determined from critical field measurements.Comment: 5 pages including 6 figures, to appear in Physical Review Letter

    Identifying Surrogates for Heart and Ipsilateral Lung Dose to Guide Field Placement and Treatment Modality Selection during Virtual Simulation of Breast Radiotherapy

    Get PDF
    AIMS: Virtual simulation (VSim) of tangential photon fields is a common method of field localisation for breast radiotherapy. Heart and ipsilateral lung dose is unknown until the dosimetric plan is produced. If heart and ipsilateral lung tolerance doses are exceeded, this can prolong the pre-treatment pathway, particularly if a change of technique is required. The aim of this study was to identify predictive surrogates for heart and ipsilateral lung dose during VSim to aid optimum field placement and treatment modality selection. MATERIALS AND METHODS: Computed tomography data from 50 patients referred for left breast/chest wall radiotherapy were retrospectively analysed (model-building cohort). The prescribed dose was 40.05 Gy in 15 fractions using a tangential photon technique. The heart and ipsilateral lung contours were duplicated, cropped to within the field borders and labelled heart-in-field (HIF) and ipsilateral lung-in-field (ILF). The percentage of HIF (%HIF) and ILF (%ILF) was calculated and correlated with mean heart dose (MHD) and volume of the ipsilateral lung receiving 18 Gy (V18Gy). Linear regression models were calculated. A validation cohort of 10 left- and 10 right-sided cases with an anterior supraclavicular fossa (SCF) field, and 10 left- and 10 right-sided cases including the internal mammary nodes using a wide tangential technique and anterior SCF field, tested the predictive model. Threshold values for %HIF and %ILF were calculated for clinically relevant MHD and ipsilateral lung V18Gy tolerance doses. RESULTS: For the model-building cohort, the median %HIF and MHD were 2.6 (0.4-16.7) and 2.3 (1.2-8) Gy. The median %ILF and ipsilateral lung V18Gy were 12.1 (2.8-33.6) and 12.6 (3.3-35) %. There was a statistically significant strong positive correlation of %HIF with MHD (r2 = 0.97, P < 0.0001) and of %ILF with ipsilateral lung V18Gy (r2 = 0.99, P < 0.0001). For the validation cohort, the median %HIF and MHD were 3.9 (0.6-8) and 2.5 (1.4-4.7) Gy. The median %ILF and ipsilateral lung V18Gy were 20.1 (12.4-32.0) and 20.9 (12.4-34.4) %. The validation cohort confirmed that %HIF and %ILF continue to be predictive surrogates for heart and ipsilateral lung dose during VSim of left- and right-sided cases when including the SCF ± internal mammary nodes with a three-field photon technique. DISCUSSION: The ability to VSim breast radiotherapy (±nodal targets) and accurately predict the heart and ipsilateral lung doses on the dosimetric plan will ensure that tolerance doses are not exceeded, and identify early in the pre-treatment pathway those cases where alternative techniques or modalities should be considered

    The application of local hypobaric pressure — A novel means to enhance macromolecule entry into the skin

    Get PDF
    AbstractThe local application of controlled hypobaric stress represents a novel means to facilitate drug delivery into the skin. The aims of this work were to understand how hypobaric stress modified the properties of the skin and assess if this penetration enhancement strategy could improve the percutaneous penetration of a macromolecule. Measurements of skin thickness demonstrated that the topical application of hypobaric stress thinned the tissue (p<0.05), atomic force microscopy showed that it shrunk the corneocytes in the stratum corneum (p<0.001) and the imaging of the skin hair follicles using multiphoton microscopy showed that it opened the follicular infundibula (p<0.001). Together, these changes contributed to a 19.6-fold increase in in vitro percutaneous penetration of a 10,000 molecular weight dextran molecule, which was shown using fluorescence microscopy to be localized around the hair follicles, when applied to the skin using hypobaric stress. In vivo, in the rat, a local hemodynamic response (i.e. a significant increase in blood flow, p<0.001) was shown to contribute to the increase in follicular transport of the dextran to produce a systemic absorption of 7.2±2.81fg·mL−1. When hypobaric stress was not applied to the rat there was no detectable absorption of dextran and this provided evidence that this novel penetration enhancement technique can improve the percutaneous penetration of macromolecules after topical application to the skin

    Context sensitive cardiac x-ray imaging: a machine vision approach to x-ray dose control

    Get PDF
    Modern cardiac x-ray imaging systems regulate their radiation output based on the thickness of the patient to maintain an acceptable signal at the input of the x-ray detector. This approach does not account for the context of the examination or the content of the image displayed. We have developed a machine vision algorithm that detects iodine-filled blood vessels and fits an idealized vessel model with the key parameters of contrast, diameter, and linear attenuation coefficient. The spatio-temporal distribution of the linear attenuation coefficient samples, when appropriately arranged, can be described by a simple linear relationship, despite the complexity of scene information. The algorithm was tested on static anthropomorphic chest phantom images under different radiographic factors and 60 dynamic clinical image sequences. It was found to be robust and sensitive to changes in vessel contrast resulting from variations in system parameters. The machine vision algorithm has the potential of extracting real-time context sensitive information that may be used for augmenting existing dose control strategies

    Employment mobility in high-technology agglomerations: the cases of Oxfordshire and Cambridgeshire

    Get PDF
    This paper examines labour market behaviour of the highly skilled in high-tech local economies, taking the UK examples of Oxfordshire and Cambridgeshire as case studies. It reports on data from a survey of members of three scientific institutes to compare rates of employee mobility in the two locations and considers the likely explanations and implications of those patterns

    Characterization of vacancy defects in Cu(In,Ga)Se2 by positron annihilation spectroscopy

    Get PDF
    The photovoltaic performance of Cu(In1-x,Gax)Se2 (CIGS) materials is commonly assumed to be degraded by the presence of vacancy-related defects. However, experimental identification of specific vacancy defects remains challenging. In this work we report positron lifetime measurements on CIGS crystals with x = 0, and x = 0.05, saturation trapping to two dominant vacancy defect types, in both types of crystal, is observed and found to be independent of temperature between 15–300 K. Atomic superposition method calculations of the positron lifetimes for a range of vacancy defects in CIS and CGS are reported. The calculated lifetimes support the assignment of the first experimental lifetime component to monovacancy or divacancy defects, and the second to trivacancies, or possibly the large In-Se divacancy. Further, the calculated positron parameters obtained here provide evidence that positron annihilation spectroscopy has the capability to identify specific vacancy-related defects in the Cu(In1-x,Gax)Se2 chalcogenides
    corecore