21 research outputs found

    Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)

    Get PDF
    Background: Patients with coronary artery disease can accumulate significant radiation dose through repeated exposures to coronary computed tomographic angiography, myocardial perfusion imaging with single photon emission computed tomography or positron emission tomography, and to invasive coronary angiography. Aim of the study was to audit radiation doses of coronary computed tomographic angiography, single photon emission computed tomography, positron emission tomography and invasive coronary angiography in patients enrolled in the prospective, randomized, multi-centre European study–EVINCI (Evaluation of Integrated Cardiac Imaging for the Detection and Characterization of Ischemic Heart Disease).Methods: We reviewed 1070 tests (476 coronary computed tomographic angiographies, 85 positron emission tomographies, 310 single photon emission computed tomographies, 199 invasive coronary angiographies) performed in 476 patients (mean age 60 ± 9 years, 60% males) enrolled in 12 centers of the EVINCI. The effective doses were calculated in milli-Sievert (mSv) as median, interquartile range (IQR) and coefficient of variation of the mean.Results: Coronary computed tomographic angiography (476 exams in 12 centers) median effective dose was 9.6 mSv (IQR = 13.2 mSv); single photon emission computed tomography (310 exams in 9 centers) effective dose was 9.3 (IQR = 2.8); positron emission tomography (85 in 3 centers) effective dose 1.8 (IQR = 1.6) and invasive coronary angiography (199 in 9 centers) effective dose 7.4 (IQR = 7.3). Inter-institutional variability was highest for invasive coronary angiography (100%) and coronary computed tomographic angiography (54%) and lowest for single photon emission computed tomography (20%). Intra-institutional variability was highest for invasive coronary angiography (121%) and coronary computed tomographic angiography (115%) and lowest for single photon emission computed tomography (14%).Conclusion: Coronary computed tomographic angiography and invasive coronary angiography doses vary substantially between and within centers. The variability in nuclear medicine procedures is substantially lower. The findings highlight the need to audit doses, to track cumulative exposures and to standardize doses for imaging techniques.Trial registration: The study protocol is available at https://www.clinicaltrials.gov/ (ClinicalTrials.gov Identifier: NCT00979199). Information provided on September 16, 2009

    Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)

    Get PDF
    Background: Patients with coronary artery disease can accumulate significant radiation dose through repeated exposures to coronary computed tomographic angiography, myocardial perfusion imaging with single photon emission computed tomography or positron emission tomography, and to invasive coronary angiography. Aim of the study was to audit radiation doses of coronary computed tomographic angiography, single photon emission computed tomography, positron emission tomography and invasive coronary angiography in patients enrolled in the prospective, randomized, multi-centre European study-EVINCI (Evaluation of Integrated Cardiac Imaging for the Detection and Characterization of Ischemic Heart Disease).Methods: We reviewed 1070 tests (476 coronary computed tomographic angiographies, 85 positron emission tomographies, 310 single photon emission computed tomographies, 199 invasive coronary angiographies) performed in 476 patients (mean age 60 +/- 9 years, 60% males) enrolled in 12 centers of the EVINCI. The effective doses were calculated in milli-Sievert (mSv) as median, interquartile range (IQR) and coefficient of variation of the mean.Results: Coronary computed tomographic angiography (476 exams in 12 centers) median effective dose was 9. 6 mSv (IQR = 13.2 mSv); single photon emission computed tomography (310 exams in 9 centers) effective dose was 9.3 (IQR = 2.8); positron emission tomography (85 in 3 centers) effective dose 1.8 (IQR = 1.6) and invasive coronary angiography (199 in 9 centers) effective dose 7.4 (IQR = 7.3). Inter-institutional variability was highest for invasive coronary angiography (100%) and coronary computed tomographic angiography (54%) and lowest for single photon emission computed tomography (20%). Intra-institutional variability was highest for invasive coronary angiography (121%) and coronary computed tomographic angiography (115%) and lowest for single photon emission computed tomography (14%).Conclusion: Coronary computed tomographic angiography and invasive coronary angiography doses vary substantially between and within centers. The variability in nuclear medicine procedures is substantially lower. The findings highlight the need to audit doses, to track cumulative exposures and to standardize doses for imaging techniques

    Boolean analysis reveals systematic interactions among low-abundance species in the human gut microbiome

    Get PDF
    The analysis of microbiome compositions in the human gut has gained increasing interest due to the broader availability of data and functional databases and substantial progress in data analysis methods, but also due to the high relevance of the microbiome in human health and disease. While most analyses infer interactions among highly abundant species, the large number of low-abundance species has received less attention. Here we present a novel analysis method based on Boolean operations applied to microbial co-occurrence patterns. We calibrate our approach with simulated data based on a dynamical Boolean network model from which we interpret the statistics of attractor states as a theoretical proxy for microbiome composition. We show that for given fractions of synergistic and competitive interactions in the model our Boolean abundance analysis can reliably detect these interactions. Analyzing a novel data set of 822 microbiome compositions of the human gut, we find a large number of highly significant synergistic interactions among these low-abundance species, forming a connected network, and a few isolated competitive interactions

    Tracking the evolutionary history of Cortinarius species in section Calochroi, with transoceanic disjunct distributions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p><it>Cortinarius </it>species in section <it>Calochroi </it>display local, clinal and circumboreal patterns of distribution across the Northern Hemisphere where these ectomycorrhizal fungi occur with host trees throughout their geographical range within a continent, or have disjunct intercontinental distributions, the origins of which are not understood. We inferred evolutionary histories of four species, 1) <it>C</it>. <it>arcuatorum</it>, 2) <it>C. aureofulvus</it>, 3) <it>C</it>. <it>elegantior </it>and 4) <it>C. napus</it>, from populations distributed throughout the Old World, and portions of the New World (Central- and North America) based on genetic variation of 154 haplotype internal transcribed spacer (ITS) sequences from 83 population samples. By describing the population structure of these species across their geographical distribution, we attempt to identify their historical migration and patterns of diversification.</p> <p>Results</p> <p>Models of population structure from nested clade, demographic and coalescent-based analyses revealed genetically differentiated and geographically structured haplotypes in <it>C</it>. <it>arcuatorum </it>and <it>C</it>. <it>elegantior</it>, while <it>C</it>. <it>aureofulvus </it>showed considerably less population structure and <it>C. napus </it>lacked sufficient genetic differentiation to resolve any population structure. Disjunct populations within <it>C</it>. <it>arcuatorum, C. aureofulvus </it>and <it>C</it>. <it>elegantior </it>show little or no morphological differentiation, whereas in <it>C. napus </it>there is a high level of homoplasy and phenotypic plasticity for veil and lamellae colour. The ITS sequences of the type specimens of <it>C. albobrunnoides </it>and <it>C. albobrunnoides </it>var. <it>violaceovelatus </it>were identical to one another and are treated as one species with a wider range of geographic distribution under <it>C. napus</it>.</p> <p>Conclusions</p> <p>Our results indicate that each of the <it>Calochroi </it>species has undergone a relatively independent evolutionary history, hypothesised as follows: 1) a widely distributed ancestral population of <it>C</it>. <it>arcuatorum </it>diverged into distinctive sympatric populations in the New World; 2) two divergent lineages in <it>C</it>. <it>elegantior </it>gave rise to the New World and Old World haplotypes, respectively; and 3) the low levels of genetic divergence within <it>C</it>. <it>aureofulvus </it>and <it>C</it>. <it>napus </it>may be the result of more recent demographic population expansions. The scenario of migration via the Bering Land Bridge provides the most probable explanation for contemporaneous disjunct geographic distributions of these species, but it does not offer an explanation for the low degree of genetic divergence between populations of <it>C. aureofulvus </it>and <it>C. napus</it>. Our findings are mostly consistent with the designation of New World allopatric populations as separate species from the European counterpart species <it>C. arcuatorum </it>and <it>C. elegantior</it>. We propose the synonymy of <it>C. albobrunnoides</it>, <it>C. albobrunnoides </it>var. <it>violaceovelatus </it>and <it>C. subpurpureophyllus </it>var. <it>sulphureovelatus </it>with <it>C. napus</it>. The results also reinforce previous observations that linked <it>C. arcuatorum </it>and <it>C. aureofulvus </it>displaying distributions in parts of North America and Europe. Interpretations of the population structure of these fungi suggest that host tree history has heavily influenced their modern distributions; however, the complex issues related to co-migration of these fungi with their tree hosts remain unclear at this time.</p

    Computer based methods for measurement of joint space width: update of an ongoing OMERACT project

    Get PDF
    Computer-based methods of measuring joint space width (JSW) could potentially have advantages over scoring joint space narrowing, with regard to increased standardization, sensitivity, and reproducibility. In an early exercise, 4 different methods showed good agreement on measured change in JSW over time in the small joints of the hands and feet. Despite differences in measurement values between methods, measurement of within-joint change over time showed no systematic differences. The within-method variation was small, with intra-operator variation being smaller than inter-operator variation. Although this initial study was limited in terms of the number of patients and timepoints (total 10), the number of joints was relatively high (340 joints), so the results were considered strong evidence supporting the validity of computer-based JSW measurements to continue the study of the potential value of JSW by comparison of measurements to manual scoring of joint space narrowing using the COBRA trial images.\ud \u
    corecore