46 research outputs found

    Spatial and Temporal Extrapolation of Disdrometer Size Distributions Based on a Lagrangian Trajectory Model of Falling Rain

    Get PDF
    Methodologies to improve disdrometer processing, loosely based on mathematical techniques common to the field of particle flow and fluid mechanics, are examined and tested. The inclusion of advection and vertical wind field estimates appears to produce significantly improved results in a Lagrangian hydrometeor trajectory model, in spite of very strict assumptions of noninteracting hydrometeors, constant vertical air velocity, and time independent advection during a radar scan time interval. Wind field data can be extracted from each radar elevation scan by plotting and analyzing reflectivity contours over the disdrometer site and by collecting the radar radial velocity data to obtain estimates of advection. Specific regions of disdrometer spectra (drop size versus time) often exhibit strong gravitational sorting signatures, from which estimates of vertical velocity can be extracted. These independent wind field estimates can be used as initial conditions to the Lagrangian trajectory simulation of falling hydrometeors.Comment: 25 pages, 15 figures, 4 tables. Submitted to The Open Atmospheric Science Journal, http://www.bentham.org/open/toascj

    Wavelet-based rotational invariant roughness features for texture classification and segmentation

    Full text link

    Laser Calibration of an Impact Disdrometer

    Get PDF
    A practical approach to developing an operational low-cost disdrometer hinges on implementing an effective in situ adaptive calibration strategy. This calibration strategy lowers the cost of the device and provides a method to guarantee continued automatic calibration. In previous work, a collocated tipping bucket rain gauge was utilized to provide a calibration signal to the disdrometer's digital signal processing software. Rainfall rate is proportional to the 11/3 moment of the drop size distribution (a 7/2 moment can also be assumed, depending on the choice of terminal velocity relationship). In the previous case, the disdrometer calibration was characterized and weighted to the 11/3 moment of the drop size distribution (DSD). Optical extinction by rainfall is proportional to the 2nd moment of the DSD. Using visible laser light as a means to focus and generate an auxiliary calibration signal, the adaptive calibration processing is significantly improved

    The next challenge for world wide robotized tele-echography experiment (WORTEX 2012): from engineering success to healthcare delivery.

    Get PDF
    Access to good quality healthcare remains difficult for many patients whether they live in developed or developing countries. In developed countries, specialist medical expertise is concentrated in major hospitals in urban settings both to improve clinical outcomes and as a strategy to reduce the costs of specialist healthcare delivery. In developing countries, millions of people have limited, if any, routine access to a healthcare system and due to economic and cultural factors the accessibility of any services may be restricted. In both cases, geographical, socio-political, cultural and economic factors produce ‘medically isolated areas’ where patients find themselves disadvantaged in terms of timely diagnosis and expert and/or expensive treatment. The robotized teleechography approach, also referred to as robotized teleultrasound, offers a potential solution to diagnostic imaging in medically isolated areas. It is designed for patients requiring ultrasound scans for routine care (e.g., ante natal care) and for diagnostic imaging to investigate acute and medical emergencies conditions, including trauma care and responses to natural disasters such as earthquakes. The robotized teleechography system can hold any standard ultrasound probe; this lightweight system is positioned on the patient’s body by a healthcare assistant. The medical expert, a clinician with expertise in ultrasound imaging and diagnosis, is in a distant location and, using a dedicated joystick, remotely controls the scanning via any available communication link (Internet, satellite). The WORTEX2012 intercontinental trials of the system conducted last year successfully demonstrated the feasibility of remote robotized tele-echography in a range of cultural, technical and clinical contexts. In addition to the engineering success, these trials provided positive feedback from the participating clinicians and patients on using the system and on the system’s perceived potential to transform healthcare in medically isolated areas. The next challenge is to show evidence that this innovative technology can deliver on its promise if introduced into routine healthcare

    Quantification of Lipoprotein Uptake in Vivo Using Magnetic Particle Imaging and Spectroscopy

    Get PDF
    Lipids are a major source of energy for most tissues, and lipid uptake and storage is therefore crucial for energy homeostasis. So far, quantification of lipid uptake in vivo has primarily relied on radioactive isotope labeling, exposing human subjects or experimental animals to ionizing radiation. Here, we describe the quantification of in vivo uptake of chylomicrons, the primary carriers of dietary lipids, in metabolically active tissues using magnetic particle imaging (MPI) and magnetic particle spectroscopy (MPS). We show that loading artificial chylomicrons (ACM) with iron oxide nanoparticles (IONPs) enables rapid and highly sensitive post hoc detection of lipid uptake in situ using MPS. Importantly, by utilizing highly magnetic Zn-doped iron oxide nanoparticles (ZnMNPs), we generated ACM with MPI tracer properties superseding the current gold-standard, Resovist, enabling quantification of lipid uptake from whole-animal scans. We focused on brown adipose tissue (BAT), which dissipates heat and can consume a large part of nutrient lipids, as a model for tightly regulated and inducible lipid uptake. High BAT activity in humans correlates with leanness and improved cardiometabolic health. However, the lack of nonradioactive imaging techniques is an important hurdle for the development of BAT-centered therapies for metabolic diseases such as obesity and type 2 diabetes. Comparison of MPI measurements with iron quantification by inductively coupled plasma mass spectrometry revealed that MPI rivals the performance of this highly sensitive technique. Our results represent radioactivity-free quantification of lipid uptake in metabolically active tissues such as BAT

    Quantification of Lipoprotein Uptake in Vivo Using Magnetic Particle Imaging and Spectroscopy

    Get PDF
    Lipids are a major source of energy for most tissues, and lipid uptake and storage is therefore crucial for energy homeostasis. So far, quantification of lipid uptake in vivo has primarily relied on radioactive isotope labeling, exposing human subjects or experimental animals to ionizing radiation. Here, we describe the quantification of in vivo uptake of chylomicrons, the primary carriers of dietary lipids, in metabolically active tissues using magnetic particle imaging (MPI) and magnetic particle spectroscopy (MPS). We show that loading artificial chylomicrons (ACM) with iron oxide nanoparticles (IONPs) enables rapid and highly sensitive post hoc detection of lipid uptake in situ using MPS. Importantly, by utilizing highly magnetic Zn-doped iron oxide nanoparticles (ZnMNPs), we generated ACM with MPI tracer properties superseding the current gold-standard, Resovist, enabling quantification of lipid uptake from whole-animal scans. We focused on brown adipose tissue (BAT), which dissipates heat and can consume a large part of nutrient lipids, as a model for tightly regulated and inducible lipid uptake. High BAT activity in humans correlates with leanness and improved cardiometabolic health. However, the lack of nonradioactive imaging techniques is an important hurdle for the development of BAT-centered therapies for metabolic diseases such as obesity and type 2 diabetes. Comparison of MPI measurements with iron quantification by inductively coupled plasma mass spectrometry revealed that MPI rivals the performance of this highly sensitive technique. Our results represent radioactivity-free quantification of lipid uptake in metabolically active tissues such as BAT

    Adaptive Mixed-Rank Filters

    No full text
    The author proposes an adaptive median-type filtering scheme which is both computationally efficient and effective in suppressing impulsive noise from images without loss of image detail. A fast implementation is briefly discussed and comparisons with other filters are presented. © 1993, The Institution of Electrical Engineers. All rights reserved

    Suppression Of Nonstationary Sinusoidal Interference Using Transform Domain Median Filtering

    No full text
    A novel technique for the suppression of sinusoidal interference by using transform domain median filtering is proposed. The most important advantage of this new technique is that estimation of the interference frequency is not needed. Other important advantages are also discussed. Residual errors are examined and compared with that of notch filtering. Experimental results with random binary sequences are presented. © 1993, The Institution of Electrical Engineers. All rights reserved
    corecore